Acoustic travel-time tomography (ATOM) determines the distribution of the temperature in a propagation medium by measuring the travel-time of acoustic signals between transmitters and receivers. To employ ATOM for indoor climate measurements, the impulse responses have been measured in the climate chamber lab of the Bauhaus-University Weimar and compared with the theoretical results of its image source model (ISM). A challenging task is distinguishing the reflections of interest in the reflectogram when the sound rays have similar travel-times. This paper presents a numerical method to address this problem by finding optimal positions of transmitter and receiver, since they have a direct impact on the distribution of travel times. These optimal positions have the minimum number of simultaneous arrival time within a threshold level. Moreover, for the tomographic reconstruction, when some of the voxels remain empty of sound-rays, it leads to inaccurate determination of the air temperature within those voxels. Based on the presented numerical method, the number of empty tomographic voxels are minimized to ensure the best sound-ray coverage of the room. Subsequently, a spatial temperature distribution is estimated by simultaneous iterative reconstruction technique (SIRT). The experimental set-up in the climate chamber verifies the simulation results.
It is widely accepted that most people spend the majority of their lives indoors. Most individuals do not realize that while indoors, roughly half of heat exchange affecting their thermal comfort is in the form of thermal infrared radiation. We show that while researchers have been aware of its thermal comfort significance over the past century, systemic error has crept into the most common evaluation techniques, preventing adequate characterization of the radiant environment. Measuring and characterizing radiant heat transfer is a critical component of both building energy efficiency and occupant thermal comfort and productivity. Globe thermometers are typically used to measure mean radiant temperature (MRT), a commonly used metric for accounting for the radiant effects of an environment at a point in space. In this paper we extend previous field work to a controlled laboratory setting to (1) rigorously demonstrate that existing correction factors used in the American Society of Heating Ventilation and Air-conditioning Engineers (ASHRAE) Standard 55 or ISO7726 for using globe thermometers to quantify MRT are not sufficient; (2) develop a correction to improve the use of globe thermometers to address problems in the current standards; and (3) show that mean radiant temperature measured with ping-pong ball-sized globe thermometers is not reliable due to a stochastic convective bias. We also provide an analysis of the maximum precision of globe sensors themselves, a piece missing from the domain in contemporary literature.
Bei Analysen des Gebäudebestands im Quartierskontext werden zu Dokumentationszwecken viele Bilddaten erzeugt. Diese Daten sind im Nachhinein häufig keinen eindeutig genauen Standorten und Blickwinkeln auf das Bauwerk zuzuordnen. Insbesondere gilt dies für Ortsunkundige oder für Detailaufnahmen. Eine zusätzliche Herausforderung stellt die Aufnahme von Wärmebrücken- oder andersartigen Gebäudedetails durch Thermogramme dar. In der Praxis kommen hier oftmals analoge, fehleranfällige Lösungen zum Einsatz.
Durch die Nutzung von Georeferenzierung kann diese Lücke geschlossen und eine eindeutige Kommunikation und Auswertung gewährleistet werden. Im Gegensatz zu den üblichen Kameras sind Smartphones nach Stand der Technik ausreichend ausgestattet, um neben Daten zu Standort auch die Orientierungswinkel einer Bildaufnahme zu dokumentieren. Die georefenzierten Bilder können auf Grundlage der in den sogenannten Exif-Daten mitgeschriebenen Informationen händisch in ein bestehendes Quartiersmodell integriert werden.
Anhand eines universitären Musterquartiers wird die nutzerfreundliche Realisierung beispielhaft erprobt und auf ihre Potentiale zur Automatisierung in Python untersucht. Hierfür wurde ein bestehendes Quartiersmodell als geometrische Grundlage genutzt und um RGB-Bilder sowie Thermogramme erweitert. Das beschriebene Vorgehen wird im Rahmen der Anwendung auf seinen möglichen Einsatz im Rahmen einer energetischen Quartierserfassung sowie einer Bauschadensdokumentation untersucht.
Mit dem vorliegenden Beitrag wird dem Nutzenden ein Werkzeug bereitgestellt, das die hochwertige Dokumentation einer Bestandserfassung, auch im Quartierskontext, ermöglicht.
This article focuses on further developments of the background-oriented schlieren (BOS) technique to visualize convective indoor air flow, which is usually defined by very small density gradients. Since the light rays deflect when passing through fluids with different densities, BOS can detect the resulting refractive index gradients as integration along a line of sight. In this paper, the BOS technique is used to yield a two-dimensional visualization of small density gradients. The novelty of the described method is the implementation of a highly sensitive BOS setup to visualize the ascending thermal plume from a heated thermal manikin with temperature differences of minimum 1 K. To guarantee steady boundary conditions, the thermal manikin was seated in a climate laboratory. For the experimental investigations, a high-resolution DLSR camera was used capturing a large field of view with sufficient detail accuracy. Several parameters such as various backgrounds, focal lengths, room air temperatures, and distances between the object of investigation, camera, and structured background were tested to find the most suitable parameters to visualize convective indoor air flow. Besides these measurements, this paper presents the analyzing method using cross-correlation algorithms and finally the results of visualizing the convective indoor air flow with BOS. The highly sensitive BOS setup presented in this article complements the commonly used invasive methods that highly influence weak air flows.
This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off.
Die Auswirkungen einer Fassadenbegrünung auf den Wärmeinseleffekt in Stuttgart wurde für eine Hitzeperiode numerisch simuliert und bewertet. Die Ergebnisse zeigten positive Auswirkungen innerhalb des Simulationsgebiets sowie eine geringe Fernwirkung auf benachbarte Stadtquartiere. Diese Änderungen können zur Verbesserung des thermischen Komforts im Außenraum beitragen. Eine reduzierte Temperatur der Außenoberfläche führt darüber hinaus auch zu einer geringeren Oberflächentemperatur der Wandinnenseite, welche die Innenraumtemperatur beeinflusst. Folglich kann die thermische Behaglichkeit auch im Innenraum erhöht werden.
Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden.
Aufgrund des visko-elastoplastischen Materialverhaltens von Beton wird Probekörpern und Bauteilen infolge zyklischer Beanspruchungen Energie zugeführt. Die entsprechenden Energiegrößen werden durch Hystereseflächen der Spannungs-Dehnungslinien beschrieben. In der Literatur finden sich dabei unterschiedliche Ansätze, wofür diese Energie verwendet wird. Erste Untersuchungen zeigen, dass zumindest ein Teil dieser dissipierten Energie in thermische Energie umgewandelt wird. Mithilfe der in diesem Beitrag beschriebenen Methodik lassen sich diese Energiegrößen für jeden Lastwechsel eines Ermüdungsversuches schnell und zuverlässig bestimmen. Anschließend wurden mit dem implementierten Algorithmus die dissipierten Energien von insgesamt 27 zyklischen Versuchen ausgewertet. Analog zu der Dehnungsentwicklung und der Steifigkeitsdegradation weisen auch die Verläufe der dissipierten Energie über die Lastwechselzahl einen dreiphasigen Verlauf auf. Die Auswertung zeigt außerdem eine Korrelation zwischen der Bruchlastwechselzahl und der dissipierten Energie. Auch der Zusammenhang zwischen Probekörpererwärmung und dissipierter Energie konnte bestätigt werden.
Kleine Kommunen im ländlichen Raum sind aufgrund ihrer oft eingeschränkten personellen und finanziellen Kapazitäten bisher eher sporadisch in den Themenfeldern Energieeffizienz und Erneuerbare Energien aktiv. Immer wieder stellt sich daher Frage, wie die Klimaschutzstrategien des Bundes und der Länder dort mit dem verfügbaren Personal kostengünstig realisierbar sind. Vor diesem Hintergrund wird ein Werkzeug entwickelt, mit dessen Hilfe der aktive Einstieg in diese Thematik mit geringen Aufwand und überwiegend barrierefrei möglich ist.
Der Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells zur Erprobung und Umsetzung bezahlbarer Handlungsoptionen für Energieeinsparungen und effizienten Energieeinsatz im überwiegend ländlichen geprägten Raum ist der Schwerpunkt der Softwarelösung.
Kommunen werden mit deren Hilfe in die Lage versetzt, in die notwendigen Prozesse der Energie- und Wärmewende einzusteigen. Dabei soll der modulare Aufbau die regulären Schritte notwendiger (integrierter) Planungsprozesse nicht vollständig ersetzen. Vielmehr können innerhalb der Online-Anwendung - überwiegend automatisiert - konkrete Maßnahmenvorschläge erstellt werden, die ein solides Fundament der künftigen energetischen Entwicklung der Kommunen darstellen.
Für eine gezielte Validierung der Ergebnisse und der Ableitung potentieller Maßnahmen werden für die Erprobung Modellkommunen in Thüringen, Bayern und Hessen als Reallabore einbezogen.
Das Tool steht bisher zunächst nur den beteiligten Modellkommunen zur Verfügung. Die entwickelte Softwarelösung soll künftig Schritt für Schritt allen interessierten Kommunen mit diversen Hilfsmitteln und einer Vielzahl anderer praktischer Bestandteile zur Verfügung gestellt werden.
The imperative to transform current energy provisions is widely acknowledged. However, scant attention has hitherto been directed toward rural municipalities and their innate resources, notably biogenic resources. In this paper, a methodological framework is developed to interconnect resources from waste, wastewater, and agricultural domains for energy utilization. This entails cataloging existing resources, delineating their potential via quantitative assessments utilizing diverse technologies, and encapsulating them in a conceptual model. The formulated models underwent iterative evaluation with engagement from diverse stakeholders. Consequently, 3 main concepts, complemented by 72 sub-concepts, were delineated, all fostering positive contributions to climate protection and providing heat supply in the rural study area. The outcomes’ replicability is underscored by the study area’s generic structure and the employed methodology. Through these inquiries, a framework for the requisite energy transition, with a pronounced emphasis on the coupling of waste, wastewater, and agriculture sectors in rural environments, is robustly analyzed.
This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model.
The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1].
This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1].
Acoustic travel-time TOMography (ATOM) allows the measurement and reconstruction of air temperature distributions. Due to limiting factors, such as the challenge of travel-time estimation of the early reflections in the room impulse response, which heavily depends on the position of transducers inside the measurement area, ATOM is applied mainly outdoors. To apply ATOM in buildings, this paper presents a numerical solution to optimize the positions of transducers. This optimization avoids reflection overlaps, leading to distinguishable travel-times in the impulse response reflectogram. To increase the accuracy of the measured temperature within tomographic voxels, an additional function is employed to the proposed numerical method to minimize the number of sound-path-free voxels, ensuring the best sound-ray coverage of the room. Subsequently, an experimental set-up has been performed to verify the proposed numerical method. The results indicate the positive impact of the optimal positions of transducers on the distribution of ATOM-temperatures.
This study investigates the flow supplied by personalized ventilation (PV) by means of anemometer measurements and schlieren visualization. The study was conducted using a thermal manikin to simulate a seated occupant facing a PV outlet. Air velocity was measured at multiple points in the flow field; the collected velocity values were used to calculate the turbulence intensity. Results indicated that PV was supplying air with low turbulence intensity that was able to penetrate the convective boundary layer of the manikin to supply clean air for inhalation. The convective boundary layer, however, obstructed the supplied flow and reduced its velocity by a total of 0.26 m/s. The PV flow preserved its value until about 10 cm from the face where velocity started to drop. Further investigations were conducted to test a PV diffuser with a relatively large outlet diameter (18 cm). This diffuser was developed using 3d-modelling and 3d-printing. The diffuser successfully distributed the flow over the larger outlet area. However, the supplied velocity and turbulence fields were not uniform across the section.
The human body is surrounded by a micro‐climate which results from its convective release of heat. In this study, the air temperature and flow velocity of this micro‐climate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the micro‐climate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the micro‐climate shape strongly depends not only on the body segment, but also on boundary conditions: the higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the air flow in the micro‐climate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient.
Im vorliegenden Beitrag werden Messungen und Berechnungen vorgestellt, die die Temperaturentwicklung in Betonzylindern aufgrund zyklischer Beanspruchung genau beschreiben. Die Messungen wurden in einem Versuchsstand, die Berechnungen im FEM-Programm ANSYS durchgeführt. Mit Hilfe der Temperaturmessungen konnten die Simulationen für die Temperaturentwicklung der Betonzylinder mit der verwendeten Betonrezeptur validiert werden. Die Untersuchungen lassen den Schluss zu, dass bei zyklischer Probekörperbelastung und der einhergehenden Probekörperdehnung Energie dissipiert wird und diese maßgeblich für die Erwärmung der Probe verantwortlich ist.
Nutzerorientierte Bausanierung bedeutet eine gegenüber dem konventionellen Vorgehen deutlich verstärkte Ausrichtung des Planungs- und Sanierungsprozesses auf die Anforderungen und Bedürfnisse des zukünftigen Nutzers eines Gebäudes. Dies hat einerseits ein hochwertigeres Produkt zum Ergebnis, erfordert andererseits aber auch den Einsatz neuer Methoden und Baustoffe sowie ein vernetztes Zusammenarbeiten aller am Bauprozess Beteiligten. Der Fokus der Publikation liegt dabei auf den Bereichen, die eine hohe Relevanz für die nutzerorientierte Bausanierung aufweisen. Dabei handelt es sich insbesondere um: Computergestütztes Bauaufmaß und digitale Bauwerksmodellierung (BIM), bauphysikalische Methoden zur Optimierung von Energieeffizienz und Behaglichkeit bei der Sanierung von Bestandsgebäuden, zerstörungsfreie Untersuchungsmethoden im Rahmen einer substanzschonenden Bauzustandsanalyse und Entwicklung von Ergänzungsbaustoffen.
Das Projekt nuBau ist eine Kooperation zwischen den Fakultäten Bauingenieurwesen und Architektur der Bauhaus-Universität Weimar. Die beteiligten Professuren sind: Bauphysik, Informatik in der Architektur, Polymere Werkstoffe und Werkstoffe des Bauens.
Occupant needs with regard to residential buildings are not well known due to a lack of representative scientific studies. To improve the lack of data, a large scale study was carried out using a Post Occupancy Evaluation of 1,416 building occupants. Several criteria describing the needs of occupants were evaluated with regard to their subjective level of relevance. Additionally, we investigated the degree to which deficiencies subjectively exist, and the degree to which occupants were able to accept them. From the data obtained, a hierarchy of criteria was created. It was found that building occupants ranked the physiological needs of air quality and thermal comfort the highest. Health hazards such as mould and contaminated building materials were unacceptable for occupants, while other deficiencies were more likely to be tolerated. Occupant satisfaction was also investigated. We found that most occupants can be classified as satisfied, although some differences do exist between different populations. To explain the relationship between the constructs of what we call relevance, acceptance, deficiency and satisfaction, we then created an explanatory model. Using correlation and regression analysis, the validity of the model was then confirmed by applying the collected data. The results of the study are both relevant in shaping further research and in providing guidance on how to maximize tenant satisfaction in real estate management.
Performance assessment of a ductless personalized ventilation system using a validated CFD model
(2018)
The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model.
The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant.