620 Ingenieurwissenschaften
Refine
Document Type
- Article (18)
- Doctoral Thesis (1)
Institute
- Institut für Strukturmechanik (ISM) (12)
- Professur Stochastik und Optimierung (11)
- Materialforschungs- und -prüfanstalt an der Bauhaus-Universität (2)
- Professur Verkehrsplanung und Verkehrstechnik (2)
- In Zusammenarbeit mit der Bauhaus-Universität Weimar (1)
- Professur Biotechnologie in der Ressourcenwirtschaft (1)
- Professur Grundbau (1)
- Professur Verkehrssystemplanung (1)
Keywords
- Angewandte Mathematik (11)
- Stochastik (11)
- Strukturmechanik (11)
- Verkehrssicherheit (2)
- Auxiliary lane; Conflict Indexes; Road safety; Traffic Conflict Technique; U-turn (1)
- Beam-to-column connection; semi-rigid; flush end-plate connection; moment-rotation curve (1)
- Beschleunigungsstreifen (1)
- Biogasanlage (1)
- Dielektrische Spektroskopie (1)
- Festphasen-Fermentation (1)
Year of publication
- 2016 (19) (remove)
Previous publications about biochar in anaerobic digestion show encouraging results with regard to increased biogas yields. This work investigates such effects in a solid-state fermentation of bio-waste. Unlike in previous trials, the influence of biochar is tested with a setup that simulates an industrial-scale biogas plant. Both the biogas and the methane yield increased around 5% with a biochar addition of 5%-based on organic dry matter biochar to bio-waste. An addition of 10% increased the yield by around 3%. While scaling effects prohibit a simple transfer of the results to industrial-scale plants, and although the certainty of the results is reduced by the heterogeneity of the bio-waste, further research in this direction seems promising.
The current study attempts to recognise an adequate classification for a semi-rigid beam-to-column connection by investigating strength, stiffness and ductility. For this purpose, an experimental test was carried out to investigate the moment-rotation (M-theta) features of flush end-plate (FEP) connections including variable parameters like size and number of bolts, thickness of end-plate, and finally, size of beams and columns. The initial elastic stiffness and ultimate moment capacity of connections were determined by an extensive analytical procedure from the proposed method prescribed by ANSI/AISC 360-10, and Eurocode 3 Part 1-8 specifications. The behaviour of beams with partially restrained or semi-rigid connections were also studied by incorporating classical analysis methods. The results confirmed that thickness of the column flange and end-plate substantially govern over the initial rotational stiffness of of flush end-plate connections. The results also clearly showed that EC3 provided a more reliable classification index for flush end-plate (FEP) connections. The findings from this study make significant contributions to the current literature as the actual response characteristics of such connections are non-linear. Therefore, such semirigid behaviour should be used to for an analysis and design method.
Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.