56.55 Bauphysik, Bautenschutz
Refine
Document Type
- Article (17)
- Conference Proceeding (7)
- Master's Thesis (3)
- Preprint (3)
- Doctoral Thesis (1)
- Study Thesis (1)
Institute
- Professur Bauphysik (32) (remove)
Keywords
- Raumklima (8)
- Bauphysik (5)
- computational fluid dynamics (5)
- Strömungsmechanik (4)
- Acoustic Travel-Time Tomography (3)
- Bauklimatik (3)
- Belüftung (3)
- Living wall (3)
- Mikroklima (3)
- OA-Publikationsfonds2022 (3)
Es werden sowohl analytische als auch numerische Verfahren zur Berechnung der Wärmeverluste von Verglasungen vorgestellt, wobei alle am Energietransport beteiligten Prozesse, die Wärmeleitung, die thermisch getriebenen Konvektionsströmungen und die infrarote Strahlungswechselwirkung, korrekt und vollständig berücksichtigt werden. Mit Hilfe numerischer Strömungssimulation werden Verglasungen systematisch hinsichtlich der Füllgasart, der Infrarotverspiegelung, der Einbaulage und des Scheibenabstandes sowie der Anzahl der Gaszwischenräume (Zwei-, Drei- und Vierscheiben-Verglasung) untersucht und verglichen. Die Abhängigkeit des k-Wertes von den Temperaturen der angrenzenden Klimate (Atmosphäre und Innenraum) wird dargestellt.
In dieser Diplomarbeit werden – anhand eines Simulationsprogrammes – die diffusen Schallfelder in Atrien untersucht. Diesbezüglich standen Referenzobjekte in Berlin zur Verfügung. Es wurde untersucht, inwieweit sich die Raumgeometrie, die Volumina und die Absorptionseigenschaften der Umhüllungsflächen auf die Energieverteilung im Atriumsraum auswirken. Ziel der Arbeit ist es, Optimierungspotenziale aufzuzeigen und Lösungsvorschläge zu entwickeln, die zeigen, mit welchen Mitteln und Methoden die Raumakustik nachträglich verbessert werden kann.
Das Ziel der vorliegenden Diplomarbeit war es, „Untersuchungen hinsichtlich des Einflusses von Phase Change Materials auf die Raumlufttemperatur“ durchzuführen und anschließend die Ergebnisse auszuwerten. Dabei galt es, thermodynamische Grundlagen zu erläutern sowie den derzeitigen Stand der Forschung darzulegen. Dies wurde umfassend bearbeitet, allerdings kann hierbei aufgrund des Umfangs und der Vielfalt im Bereich der internationalen PCM-Forschung kein Anspruch auf Vollständigkeit erhoben werden. Ein Hauptteil dieser Arbeit bestand darin, den Versuchsaufbau der Referenzräume im Eiermann-Bau in Apolda als Grundlage für spätere Messungen detailliert zu beschreiben. Dabei wurde auf die gesamte Messanlage, die eingebrachten PCM sowie auf daraus resultierende physikalische Kenngrößen ausführlich eingegangen. Es galt, geometrische, chemische und physikalische Einflüsse einzuschätzen, aber auch Schwachstellen aufzudecken, um die später folgenden Messreihen exakt auswerten zu können. Als kritisch einzuschätzende Größe fiel dabei besonders das eingebrachte Salzgemisch auf, welches hinsichtlich des Schmelz- und Kristallisationsbereiches als kaum beurteilbar auffiel. Dies konnte auch nach mehreren Untersuchungen, hier ist insbesondere die dynamische Differenzkalorimetrie zu nennen, nicht hinreichend geklärt werden. Basierend auf diesen Erkenntnissen wurden vergleichende Messreihen durchgeführt, welche durch verschiedene Luftwechselraten gestaltet wurden. Im Maximum konnte dabei im PCM-konditionierten Raum eine Reduktion der Temperatur um 6 K erreicht werden. Dabei muss allerdings berücksichtigt werden, dass diese Differenz größtenteils auf die thermische Masse des Salzgemischs zurückgeführt werden kann. Eine abschließende Messung ohne Salzgemisch zeigte, dass aufgrund des latenten Wärmespeichervermögens des PCM-Putzes lediglich eine thermische Differenz von 2 K erreicht werden kann. Hinsichtlich der Luftwechselrate ist anzumerken, dass die erwartete, vergleichsweise zügige Auskühlung trotz Lüftung in der Praxis nicht nachvollzogen werden konnte. Zur Auswertung der gewonnenen Messwerte galt es, das am Lehrstuhl Bauphysik vorhandene mathematische Minimalmodell auf die am Objekt vorhandenen Randbedingungen anzupassen. Aus den Datenwolken der Atmosphärentemperatur sowie der Globalstrahlung mussten Funktionen approximiert werden, da diese äußeren Zwänge einen entscheidenden Einfluss auf den Verlauf der Innenraumtemperatur ausüben. Die Ergebnisse der Berechungen des Temperaturverlaufs können als zufrieden stellend betrachtet werden, jedoch wurde deutlich, dass ein genaues Nachstellen nicht möglich ist. Dies ist vor allem auf die Tatsache zurückzuführen, dass das Minimalmodell lediglich eine Beschreibung der wesentlichen Prozesse mathematisch abbildet. Eine kritische Auseinandersetzung hinsichtlich allgemeiner Standpunkte als auch der Anwendbarkeit auf die Referenzräume wurde abschließend diskutiert.
Overheating is a major problem in many modern buildings due to the utilization of lightweight constructions with low heat storing capacity. A possible answer to this problem is the emplacement of phase change materials (PCM), thereby increasing the thermal mass of a building. These materials change their state of aggregation within a defined temperature range. Useful PCM for buildings show a phase transition from solid to liquid and vice versa. The thermal mass of the materials is increased by the latent heat. A modified gypsum plaster and a salt mixture were chosen as two materials for the study of their impact on room temperature reduction. For realistic investigations, test rooms were erected where measurements were carried out under different conditions such as temporary air change, alternate internal heat gains or clouding. The experimental data was finally reproduced by dint of a mathematical model.
Patients and staff in hospitals are exposed to a complex sound environment with rather high noise levels. In intensive care units, the main noise sources are hospital staff on duty and medical equipment, which generates both operating noise and acoustic alarms. Although noise in most cases is produced during activities for the purpose of saving life, noise can induce significant changes in the depth and quality of sleep and negatively affect health in general. Results of a survey of hospital staff are presented as well as measurements in two German hospital wards: a standard two-bed room and a special Intermediate Care Unit (IMC-Unit), each in a different Intensive Care Unit (ICU). Sound pressure data were collected over a 48 hour period and converted into different levels (LAFeq, LAFmax, LAFmin, LAF 5%), as well as a rating level LAr, which is used to take tonality and impulsiveness into account. An analysis of the survey and the measured data, together with a comparison of thresholds of national and international regulations and standards describe the acoustic situation and its likely noise effects on staff and patients.
Capturing Sheep With Minecraft befasst sich mit ausgewählten Problemen der Bauphysik und deren Umsetzung mithilfe des Computerspiels Minecraft. Es werden ausgewählte Probleme der Bauphysik in Minecraft abgebildet um diese Schülern und Studenten näher zu bringen. Es wurde ein Szenario in Minecraft entworfen welches durch entgegenwirken der abgebildeten Probleme, durch den Spieler gelöst werden soll.
The human body is surrounded by a micro‐climate which results from its convective release of heat. In this study, the air temperature and flow velocity of this micro‐climate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the micro‐climate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the micro‐climate shape strongly depends not only on the body segment, but also on boundary conditions: the higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the air flow in the micro‐climate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient.
Performance assessment of a ductless personalized ventilation system using a validated CFD model
(2018)
The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model.
This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of the human body back and forth between the CFD solver and the UCB model until reaching convergence defined by a stopping criterion. The location from which data are transferred to the UCB model was determined using a new approach based on the temperature difference between subsequent points on the temperature profile curve in the vicinity of the body surface. This approach was used because the microclimate surrounding the human body differs in thickness depending on the body segment and the surrounding environment. To accurately simulate the thermal environment, the numerical model was validated beforehand using experimental data collected in a climate chamber equipped with a thermal manikin. Furthermore, an example of the practical implementations of this coupling is reported in this paper through radiant floor cooling simulation cases, in which overall and local thermal sensation and comfort were investigated using the coupled UCB model.