Refine
Document Type
- Article (23)
- Conference Proceeding (8)
- Bachelor Thesis (6)
- Master's Thesis (5)
- Doctoral Thesis (4)
- Preprint (3)
- Report (2)
- Study Thesis (2)
Institute
- Professur Bauphysik (53) (remove)
Keywords
- Bauphysik (10)
- Raumklima (8)
- Bauklimatik (5)
- computational fluid dynamics (5)
- Acoustic Travel-Time Tomography (4)
- Simulation (4)
- Strömungsmechanik (4)
- Akustische Laufzeit-Tomographie (3)
- BIM (3)
- Belüftung (3)
- Living wall (3)
- Mikroklima (3)
- OA-Publikationsfonds2022 (3)
- OA-Publikationsfonds2023 (3)
- Wärmeübertragung (3)
- schlieren imaging (3)
- thermal comfort (3)
- Behaglichkeit (2)
- Building Information Modeling (2)
- CFD (2)
- Delphin (2)
- Dissipation (2)
- ENVI-Met (2)
- Energiebedarf (2)
- Energiewende (2)
- Ermüdung (2)
- Feuchteleitung (2)
- Gebäude (2)
- Gebäudehülle (2)
- Gebäudesimulation (2)
- Heat transport (2)
- IFC-basierte Gebäudesimulation (2)
- Latentwärmespeicher (2)
- Lernspiel (2)
- Luftqualität (2)
- Measurements (2)
- Messung (2)
- Moisture transport (2)
- PCM (2)
- Personalized ventilation (2)
- Raumakustik (2)
- Schlieren imaging (2)
- Schnittstelle (2)
- building simulation (2)
- cyclic load (2)
- ductless personalized ventilation (2)
- heat transfer coefficient (2)
- indoor air quality (2)
- personalized ventilation (2)
- phase change materials (2)
- thermische Gebäudehülle (2)
- Abfallwirtschaft (1)
- Absorber (1)
- Absorberelement (1)
- Absorption (1)
- Absorptionskoeffizient (1)
- Abwassermanagement (1)
- Air quality (1)
- Akustik (1)
- Akustik im Barock (1)
- Akustische Tomographie (1)
- Arbeitsplatz (1)
- Architektur <Informatik> (1)
- Aufwindkraftwerk (1)
- Axial fan (1)
- Background-oriented schlieren (1)
- Bauakustik (1)
- Bauphysik und Sanierung (1)
- Baustoff Quartett (1)
- Benutzung (1)
- Beton (1)
- Bilddaten (1)
- Bildverarbeitung (1)
- Biomasse (1)
- Blasinstrument (1)
- BuildVille (1)
- CAD (1)
- Computersimulation (1)
- Computerunterstütztes Lernen (1)
- Computerunterstütztes Verfahren (1)
- Convective indoor air flow (1)
- Covid-19 (1)
- Cross-correlation (1)
- Crowdsourcing (1)
- Deutlichkeit (1)
- Diffusionswärme (1)
- Diffusität (1)
- Digital Game Based Learning (1)
- Digital Games Based Learning (1)
- Digital image correlation (1)
- Dissipationsenergie (1)
- ENVI-met (1)
- Energieplanung (1)
- Energietransport (1)
- Envi-Met (1)
- Ergänzungsbaustoffe (1)
- Facebook (1)
- Fahrradergometer (1)
- Fassadenbegrünung (1)
- Feuchtepufferung (1)
- Finite-Volumen-Methode (1)
- Fliplife (1)
- Fliplife Mitarbeiterrekrutierung (1)
- Flow visualization (1)
- Fluid (1)
- Gebäudesimulation ESP-r (1)
- Gesang (1)
- Gesellschaftsspiel (1)
- Globe thermometers (1)
- Green facade (1)
- Human thermal plume (1)
- IAQ (1)
- Indoor environment (1)
- Intensivstation (1)
- Kirchenbau (1)
- Klarheitsmaß (1)
- Kommune (1)
- Kontamination (1)
- Konvektion (1)
- Kupplung (1)
- Körperschall (1)
- Lautstärke (1)
- Leitung (1)
- Lernen nach Gagné (1)
- Lernspiele (1)
- Living-wall (1)
- Lärm (1)
- Lüftung (1)
- Lüftungsanlage (1)
- Mathematisches Modell (1)
- Mean radiant temperature (1)
- Minecraft (1)
- Missionsmanager (1)
- Modellierung (1)
- Multiplayer (1)
- Musik im Barock (1)
- Nachhall (1)
- Nachhallzeit (1)
- Numerische Strömungsmechanik (1)
- Numerische Strömungssimulation (1)
- Nutzerorientierte Bausanierung (1)
- PCM-Putz (1)
- PCM-plaster (1)
- Pandemie (1)
- Paraffin (1)
- Phase Change Materials (1)
- Phasenumwandlung (1)
- Phasenübergangsmaterialien (1)
- Photothermische Methode (1)
- Post Occupancy Evaluation (1)
- Probekörpererwärmung (1)
- Probleme (1)
- Quartett (1)
- Quartiersanalyse (1)
- Raumakustische Rekonstruktion (1)
- Raumeindruck (1)
- Raumluftströmungen (1)
- Raumlufttemperatur (1)
- Regionalentwicklung (1)
- Rekonstruktion (1)
- Schall (1)
- Schlierenmethode (1)
- Schlierenspiegel (1)
- Simulations (1)
- Singleplayer (1)
- Skill (1)
- Skillmanager (1)
- Skillsystem (1)
- Social Game (1)
- Social Games (1)
- Sonnenenergie (1)
- Sonnenkollektor (1)
- Spieler (1)
- Spielermodell (1)
- Sport (1)
- Strahlung (1)
- Strahlungstemperatur (1)
- Strömung (1)
- Strömungsfeld (1)
- Städtische Wärmeinsel (1)
- Temperatur (1)
- Temperaturfeld (1)
- Thermal comfort (1)
- Thermal manikin (1)
- Thermodynamik (1)
- Thermography (1)
- Training (1)
- Transformation (1)
- Transportgleichung (1)
- UCB model (1)
- Umfrage (1)
- Validierung (1)
- Ventilation (1)
- Verglasung (1)
- Visualisierung (1)
- Visualization (1)
- Weimar / Schloss Wilhelmsburg / Schlosskapelle Himmelsburg (1)
- Wärmeempfindung (1)
- Wärmeverlust (1)
- Wärmeübergang (1)
- Wärmeübergangskoeffizient (1)
- Wärmeübergangskoeffizient an Zylinder (1)
- Wärmeübergangszahl (1)
- Zyklische Beanspruchung (1)
- acoustical measurement (1)
- airborne infection (1)
- background-oriented schlieren (1)
- bauphysikalische Methoden (1)
- biogene Abfallstoffe (1)
- building acoustics (1)
- climate chamber (1)
- computer simulation (1)
- conduction (1)
- convection (1)
- coupling (1)
- cross-contamination (1)
- cycle ergometer (1)
- desk fan (1)
- fatigue (1)
- game mechanic (1)
- heat storage (1)
- heat transfer coefficient for cylinders (1)
- historic church (1)
- historic palace (1)
- housing (1)
- human thermal plume (1)
- intensive care unit (1)
- k-Wert (1)
- latent heat storage (1)
- ländlicher Raum (1)
- mathematical model (1)
- mathematical modelling (1)
- micro climate (1)
- microclimate (1)
- noise (1)
- numerical simulation (1)
- occupant requirements (1)
- occupant satisfaction (1)
- organischer Abfall (1)
- particles concentration (1)
- personalisierte Lüftung (1)
- questionnaire (1)
- radiation (1)
- residential buildings (1)
- room acoustics (1)
- salt hydrate (1)
- schlieren velocimetry (1)
- social game (1)
- solar energy (1)
- sommerlicher Wärmeschutz (1)
- sound pressure level prediction (1)
- sport (1)
- structure-borne sound (1)
- structure-borne sound sources (1)
- summer overheating in buildings (1)
- thermal building simulation (1)
- thermal glazings (1)
- thermal manikin (1)
- thermal protection (1)
- thermal sensation (1)
- thermisches Empfinden (1)
- thermodynamics (1)
- thermography (1)
- tracer gas (1)
- training (1)
- transport of energy (1)
- upwind power plant (1)
- validation (1)
- zerstörungsfreie Prüfung (1)
- zyklische Beanspruchung (1)
- Überhitzung (1)
- äquivalente Temperatur (1)
Das Ziel der vorliegenden Diplomarbeit war es, „Untersuchungen hinsichtlich des Einflusses von Phase Change Materials auf die Raumlufttemperatur“ durchzuführen und anschließend die Ergebnisse auszuwerten. Dabei galt es, thermodynamische Grundlagen zu erläutern sowie den derzeitigen Stand der Forschung darzulegen. Dies wurde umfassend bearbeitet, allerdings kann hierbei aufgrund des Umfangs und der Vielfalt im Bereich der internationalen PCM-Forschung kein Anspruch auf Vollständigkeit erhoben werden. Ein Hauptteil dieser Arbeit bestand darin, den Versuchsaufbau der Referenzräume im Eiermann-Bau in Apolda als Grundlage für spätere Messungen detailliert zu beschreiben. Dabei wurde auf die gesamte Messanlage, die eingebrachten PCM sowie auf daraus resultierende physikalische Kenngrößen ausführlich eingegangen. Es galt, geometrische, chemische und physikalische Einflüsse einzuschätzen, aber auch Schwachstellen aufzudecken, um die später folgenden Messreihen exakt auswerten zu können. Als kritisch einzuschätzende Größe fiel dabei besonders das eingebrachte Salzgemisch auf, welches hinsichtlich des Schmelz- und Kristallisationsbereiches als kaum beurteilbar auffiel. Dies konnte auch nach mehreren Untersuchungen, hier ist insbesondere die dynamische Differenzkalorimetrie zu nennen, nicht hinreichend geklärt werden. Basierend auf diesen Erkenntnissen wurden vergleichende Messreihen durchgeführt, welche durch verschiedene Luftwechselraten gestaltet wurden. Im Maximum konnte dabei im PCM-konditionierten Raum eine Reduktion der Temperatur um 6 K erreicht werden. Dabei muss allerdings berücksichtigt werden, dass diese Differenz größtenteils auf die thermische Masse des Salzgemischs zurückgeführt werden kann. Eine abschließende Messung ohne Salzgemisch zeigte, dass aufgrund des latenten Wärmespeichervermögens des PCM-Putzes lediglich eine thermische Differenz von 2 K erreicht werden kann. Hinsichtlich der Luftwechselrate ist anzumerken, dass die erwartete, vergleichsweise zügige Auskühlung trotz Lüftung in der Praxis nicht nachvollzogen werden konnte. Zur Auswertung der gewonnenen Messwerte galt es, das am Lehrstuhl Bauphysik vorhandene mathematische Minimalmodell auf die am Objekt vorhandenen Randbedingungen anzupassen. Aus den Datenwolken der Atmosphärentemperatur sowie der Globalstrahlung mussten Funktionen approximiert werden, da diese äußeren Zwänge einen entscheidenden Einfluss auf den Verlauf der Innenraumtemperatur ausüben. Die Ergebnisse der Berechungen des Temperaturverlaufs können als zufrieden stellend betrachtet werden, jedoch wurde deutlich, dass ein genaues Nachstellen nicht möglich ist. Dies ist vor allem auf die Tatsache zurückzuführen, dass das Minimalmodell lediglich eine Beschreibung der wesentlichen Prozesse mathematisch abbildet. Eine kritische Auseinandersetzung hinsichtlich allgemeiner Standpunkte als auch der Anwendbarkeit auf die Referenzräume wurde abschließend diskutiert.