Refine
Document Type
- Article (12)
- Conference Proceeding (2)
Institute
- Professur Bauphysik (14) (remove)
Keywords
- computational fluid dynamics (5)
- Belüftung (3)
- Living wall (3)
- OA-Publikationsfonds2022 (3)
- Raumklima (3)
- Strömungsmechanik (3)
- Delphin (2)
- ENVI-Met (2)
- Feuchteleitung (2)
- Heat transport (2)
- Luftqualität (2)
- Measurements (2)
- Mikroklima (2)
- Moisture transport (2)
- Personalized ventilation (2)
- Schlieren imaging (2)
- Simulation (2)
- ductless personalized ventilation (2)
- indoor air quality (2)
- personalized ventilation (2)
- schlieren imaging (2)
- thermal comfort (2)
- Air quality (1)
- Axial fan (1)
- Behaglichkeit (1)
- Bildverarbeitung (1)
- Blasinstrument (1)
- Covid-19 (1)
- Diffusionswärme (1)
- ENVI-met (1)
- Envi-Met (1)
- Fahrradergometer (1)
- Fassadenbegrünung (1)
- Fluid (1)
- Gesang (1)
- Globe thermometers (1)
- Green facade (1)
- IAQ (1)
- Indoor environment (1)
- Kontamination (1)
- Kupplung (1)
- Living-wall (1)
- Lüftung (1)
- Lüftungsanlage (1)
- Mean radiant temperature (1)
- Messung (1)
- Numerische Strömungssimulation (1)
- OA-Publikationsfonds2023 (1)
- Pandemie (1)
- Photothermische Methode (1)
- Schlierenmethode (1)
- Simulations (1)
- Sport (1)
- Strahlungstemperatur (1)
- Strömung (1)
- Städtische Wärmeinsel (1)
- Temperatur (1)
- Thermal comfort (1)
- Thermal manikin (1)
- Thermography (1)
- Training (1)
- UCB model (1)
- Validierung (1)
- Ventilation (1)
- Visualisierung (1)
- Visualization (1)
- Wärmeempfindung (1)
- Wärmeübergangszahl (1)
- Wärmeübertragung (1)
- airborne infection (1)
- background-oriented schlieren (1)
- coupling (1)
- cross-contamination (1)
- cycle ergometer (1)
- desk fan (1)
- heat transfer coefficient (1)
- microclimate (1)
- particles concentration (1)
- personalisierte Lüftung (1)
- sport (1)
- thermal sensation (1)
- thermisches Empfinden (1)
- tracer gas (1)
- training (1)
- validation (1)
- äquivalente Temperatur (1)
Besides their multiple known benefits regarding urban microclimate, living walls can be used as decentralized stand-alone systems to treat greywater locally at the buildings. While this offers numerous environmental advantages, it can have a considerable impact on the hygrothermal performance of the facade as such systems involve bringing large quantities of water onto the facade. As it is difficult to represent complex entities such as plants in the typical simulation tools used for heat and moisture transport, this study suggests a new approach to tackle this challenge by coupling two tools: ENVI-Met and Delphin. ENVI-Met was used to simulate the impact of the plants to determine the local environmental parameters at the living wall. Delphin, on the other hand, was used to conduct the hygrothermal simulations using the local parameters calculated by ENVI-Met. Four wall constructions were investigated in this study: an uninsulated brick wall, a precast concrete plate, a sandy limestone wall, and a double-shell wall. The results showed that the living wall improved the U-value, the exterior surface temperature, and the heat flux through the wall. Moreover, the living wall did not increase the risk of moisture in the wall during winter and eliminated the risk of condensation.
Physical exercise demonstrates a special case of aerosol emission due to its associated elevated breathing rate. This can lead to a faster spread of airborne viruses and respiratory diseases. Therefore, this study investigates cross-infection risk during training. Twelve human subjects exercised on a cycle ergometer under three mask scenarios: no mask, surgical mask, and FFP2 mask. The emitted aerosols were measured in a grey room with a measurement setup equipped with an optical particle sensor. The spread of expired air was qualitatively and quantitatively assessed using schlieren imaging. Moreover, user satisfaction surveys were conducted to evaluate the comfort of wearing face masks during training. The results indicated that both surgical and FFP2 masks significantly reduced particles emission with a reduction efficiency of 87.1% and 91.3% of all particle sizes, respectively. However, compared to surgical masks, FFP2 masks provided a nearly tenfold greater reduction of the particle size range with long residence time in the air (0.3–0.5 μm). Furthermore, the investigated masks reduced exhalation spreading distances to less than 0.15 m and 0.1 m in the case of the surgical mask and FFP2 mask, respectively. User satisfaction solely differed with respect to perceived dyspnea between no mask and FFP2 mask conditions.
Die Auswirkungen einer Fassadenbegrünung auf den Wärmeinseleffekt in Stuttgart wurde für eine Hitzeperiode numerisch simuliert und bewertet. Die Ergebnisse zeigten positive Auswirkungen innerhalb des Simulationsgebiets sowie eine geringe Fernwirkung auf benachbarte Stadtquartiere. Diese Änderungen können zur Verbesserung des thermischen Komforts im Außenraum beitragen. Eine reduzierte Temperatur der Außenoberfläche führt darüber hinaus auch zu einer geringeren Oberflächentemperatur der Wandinnenseite, welche die Innenraumtemperatur beeinflusst. Folglich kann die thermische Behaglichkeit auch im Innenraum erhöht werden.
This study investigates the flow supplied by personalized ventilation (PV) by means of anemometer measurements and schlieren visualization. The study was conducted using a thermal manikin to simulate a seated occupant facing a PV outlet. Air velocity was measured at multiple points in the flow field; the collected velocity values were used to calculate the turbulence intensity. Results indicated that PV was supplying air with low turbulence intensity that was able to penetrate the convective boundary layer of the manikin to supply clean air for inhalation. The convective boundary layer, however, obstructed the supplied flow and reduced its velocity by a total of 0.26 m/s. The PV flow preserved its value until about 10 cm from the face where velocity started to drop. Further investigations were conducted to test a PV diffuser with a relatively large outlet diameter (18 cm). This diffuser was developed using 3d-modelling and 3d-printing. The diffuser successfully distributed the flow over the larger outlet area. However, the supplied velocity and turbulence fields were not uniform across the section.
This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model.
The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1].
It is widely accepted that most people spend the majority of their lives indoors. Most individuals do not realize that while indoors, roughly half of heat exchange affecting their thermal comfort is in the form of thermal infrared radiation. We show that while researchers have been aware of its thermal comfort significance over the past century, systemic error has crept into the most common evaluation techniques, preventing adequate characterization of the radiant environment. Measuring and characterizing radiant heat transfer is a critical component of both building energy efficiency and occupant thermal comfort and productivity. Globe thermometers are typically used to measure mean radiant temperature (MRT), a commonly used metric for accounting for the radiant effects of an environment at a point in space. In this paper we extend previous field work to a controlled laboratory setting to (1) rigorously demonstrate that existing correction factors used in the American Society of Heating Ventilation and Air-conditioning Engineers (ASHRAE) Standard 55 or ISO7726 for using globe thermometers to quantify MRT are not sufficient; (2) develop a correction to improve the use of globe thermometers to address problems in the current standards; and (3) show that mean radiant temperature measured with ping-pong ball-sized globe thermometers is not reliable due to a stochastic convective bias. We also provide an analysis of the maximum precision of globe sensors themselves, a piece missing from the domain in contemporary literature.
The spread of breathing air when playing wind instruments and singing was investigated and visualized using two methods: (1) schlieren imaging with a schlieren mirror and (2) background-oriented schlieren (BOS). These methods visualize airflow by visualizing density gradients in transparent media. The playing of professional woodwind and brass instrument players, as well as professional classical trained singers were investigated to estimate the spread distances of the breathing air. For a better comparison and consistent measurement series, a single high note, a single low note, and an extract of a musical piece were investigated. Additionally, anemometry was used to determine the velocity of the spreading breathing air and the extent to which it was quantifiable. The results showed that the ejected airflow from the examined instruments and singers did not exceed a spreading range of 1.2 m into the room. However, differences in the various instruments have to be considered to assess properly the spread of the breathing air. The findings discussed below help to estimate the risk of cross-infection for wind instrument players and singers and to develop efficacious safety precautions, which is essential during critical health periods such as the current COVID-19 pandemic.
This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1].
Personalized ventilation (PV) is a mean of delivering conditioned outdoor air into the breathing zone of the occupants. This study aims to qualitatively investigate the personalized flows using two methods of visualization: (1) schlieren imaging using a large schlieren mirror and (2) thermography using an infrared camera. While the schlieren imaging was used to render the velocity and mass transport of the supplied flow, thermography was implemented to visualize the air temperature distribution induced by the PV. Both studies were conducted using a thermal manikin to simulate an occupant facing a PV outlet. As a reference, the flow supplied by an axial fan and a cased axial fan was visualized with the schlieren system as well and compared to the flow supplied by PV. Schlieren visualization results indicate that the steady, low-turbulence flow supplied by PV was able to penetrate the thermal convective boundary layer encasing the manikin's body, providing clean air for inhalation. Contrarily, the axial fan diffused the supplied air over a large target area with high turbulence intensity; it only disturbed the convective boundary layer rather than destroying it. The cased fan supplied a flow with a reduced target area which allowed supplying more air into the breathing zone compared to the fan. The results of thermography visualization showed that the supplied cool air from PV penetrated the corona-shaped thermal boundary layer. Furthermore, the supplied air cooled the surface temperature of the face, which indicates the large impact of PV on local thermal sensation and comfort.
Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden.