Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 89 von 1015
Zurück zur Trefferliste

Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations

  • The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on theThe performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Metadaten
Dokumentart:Artikel (Wissenschaftlicher)
Verfasserangaben:Dr.-Ing. Hayder AlsaadORCiDGND, Prof. Conrad VölkerORCiDGND
DOI (Zitierlink):https://doi.org/10.1111/ina.12672Zitierlink
URN (Zitierlink):https://nbn-resolving.org/urn:nbn:de:gbv:wim2-20200422-41407Zitierlink
URL:https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12672
Titel des übergeordneten Werkes (Deutsch):Indoor Air
Verlag:John Wiley & Sons Ltd
Sprache:Englisch
Datum der Veröffentlichung (online):22.04.2020
Datum der Erstveröffentlichung:07.04.2020
Datum der Freischaltung:22.04.2020
Veröffentlichende Institution:Bauhaus-Universität Weimar
Institute und Partnereinrichtugen:Fakultät Bauingenieurwesen / Professur Bauphysik
Jahrgang:2020
Seitenzahl:14
Freies Schlagwort / Tag:IAQ; computational fluid dynamics; desk fan; ductless personalized ventilation; thermal comfort
GND-Schlagwort:Behaglichkeit; Raumklima; Strömungsmechanik; Fluid
DDC-Klassifikation:500 Naturwissenschaften und Mathematik / 530 Physik / 532 Mechanik der Fluide; Mechanik der Flüssigkeiten
BKL-Klassifikation:56 Bauwesen / 56.55 Bauphysik, Bautenschutz
Lizenz (Deutsch):License Logo Creative Commons 4.0 - Namensnennung-Nicht kommerziell (CC BY-NC 4.0)