Classification System for Semi-Rigid Beam-to-Column Connections

  • The current study attempts to recognise an adequate classification for a semi-rigid beam-to-column connection by investigating strength, stiffness and ductility. For this purpose, an experimental test was carried out to investigate the moment-rotation (M-theta) features of flush end-plate (FEP) connections including variable parameters like size and number of bolts, thickness of end-plate, andThe current study attempts to recognise an adequate classification for a semi-rigid beam-to-column connection by investigating strength, stiffness and ductility. For this purpose, an experimental test was carried out to investigate the moment-rotation (M-theta) features of flush end-plate (FEP) connections including variable parameters like size and number of bolts, thickness of end-plate, and finally, size of beams and columns. The initial elastic stiffness and ultimate moment capacity of connections were determined by an extensive analytical procedure from the proposed method prescribed by ANSI/AISC 360-10, and Eurocode 3 Part 1-8 specifications. The behaviour of beams with partially restrained or semi-rigid connections were also studied by incorporating classical analysis methods. The results confirmed that thickness of the column flange and end-plate substantially govern over the initial rotational stiffness of of flush end-plate connections. The results also clearly showed that EC3 provided a more reliable classification index for flush end-plate (FEP) connections. The findings from this study make significant contributions to the current literature as the actual response characteristics of such connections are non-linear. Therefore, such semirigid behaviour should be used to for an analysis and design method.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Document Type:Article
Author: Iman Faridmehr, Mamood Md. Tahir, Tom LahmerORCiDGND
DOI (Cite-Link):https://doi.org/10.1590/1679-78252595Cite-Link
URN (Cite-Link):https://nbn-resolving.org/urn:nbn:de:gbv:wim2-20170401-30988Cite-Link
Parent Title (English):LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES 11
Language:English
Date of Publication (online):2017/04/01
Year of first Publication:2016
Release Date:2017/04/01
Publishing Institution:Bauhaus-Universität Weimar
Institutes and partner institutions:Fakultät Bauingenieurwesen / Institut für Strukturmechanik (ISM)
First Page:2152
Last Page:2175
Tag:Beam-to-column connection; semi-rigid; flush end-plate connection; moment-rotation curve
GND Keyword:Tragfähigkeit; Stütze; Träger
Dewey Decimal Classification:600 Technik, Medizin, angewandte Wissenschaften / 620 Ingenieurwissenschaften
BKL-Classification:56 Bauwesen / 56.13 Stahlbau, Metallbau