TY - JOUR A1 - Mehling, Simon A1 - Schnabel, Tobias A1 - Londong, Jörg T1 - Investigation on Energetic Efficiency of Reactor Systems for Oxidation of Micro-Pollutants by Immobilized Active Titanium Dioxide Photocatalysis JF - Water N2 - In this work, the degradation performance for the photocatalytic oxidation of eight micropollutants (amisulpride, benzotriazole, candesartan, carbamazepine, diclofenac, gabapentin, methlybenzotriazole, and metoprolol) within real secondary effluent was investigated using three different reactor designs. For all reactor types, the influence of irradiation power on its reaction rate and energetic efficiency was investigated. Flat cell and batch reactor showed almost similar substance specific degradation behavior. Within the immersion rotary body reactor, benzotriazole and methylbenzotriazole showed a significantly lower degradation affinity. The flat cell reactor achieved the highest mean degradation rate, with half time values ranging from 5 to 64 min with a mean of 18 min, due to its high catalysts surface to hydraulic volume ratio. The EE/O values were calculated for all micro-pollutants as well as the mean degradation rate constant of each experimental step. The lowest substance specific energy per order (EE/O) values of 5 kWh/m3 were measured for benzotriazole within the batch reactor. The batch reactor also reached the lowest mean values (11.8–15.9 kWh/m3) followed by the flat cell reactor (21.0–37.0 kWh/m3) and immersion rotary body reactor (23.9–41.0 kWh/m3). Catalyst arrangement and irradiation power were identified as major influences on the energetic performance of the reactors. Low radiation intensities as well as the use of submerged catalyst arrangement allowed a reduction in energy demand by a factor of 3–4. A treatment according to existing treatment goals of wastewater treatment plants (80% total degradation) was achieved using the batch reactor with a calculated energy demand of 7000 Wh/m3. KW - Fotokatalyse KW - Abwasserreinigung KW - photocatalysis KW - micro-pollutant treatment KW - titanium dioxid KW - reactor design KW - energy per order KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220912-47130 UR - https://www.mdpi.com/2073-4441/14/17/2681 VL - 2022 IS - Volume 14, issue 7, article 2681 SP - 1 EP - 15 PB - MDPI CY - Basel ER - TY - JOUR A1 - Londong, Jörg A1 - Barth, Marcus A1 - Söbke, Heinrich T1 - Modeling and Simulation of Source Separation in Sanitation Systems for Reducing Emissions of Antimicrobial Resistances JF - Water N2 - Antimicrobial resistance (AMR) is identified by the World Health Organization (WHO) as one of the top ten threats to public health worldwide. In addition to public health, AMR also poses a major threat to food security and economic development. Current sanitation systems contribute to the emergence and spread of AMR and lack effective AMR mitigation measures. This study assesses source separation of blackwater as a mitigation measure against AMR. A source-separation-modified combined sanitation system with separate collection of blackwater and graywater is conceptually described. Measures taken at the source, such as the separate collection and discharge of material flows, were not considered so far on a load balance basis, i.e., they have not yet been evaluated for their effectiveness. The sanitation system described is compared with a combined system and a separate system regarding AMR emissions by means of simulation. AMR is represented in the simulation model by one proxy parameter each for antibiotics (sulfamethoxa-zole), antibiotic-resistant bacteria (extended-spectrum beta-lactamase E. Coli), and antibiotic re-sistance genes (blaTEM). The simulation results suggest that the source-separation-based sanitation system reduces emissions of antibiotic-resistant bacteria and antibiotic resistance genes into the aquatic environment by more than six logarithm steps compared to combined systems. Sulfa-methoxazole emissions can be reduced by 75.5% by keeping blackwater separate from graywater and treating it sufficiently. In summary, sanitation systems incorporating source separation are, to date, among the most effective means of preventing the emission of AMR into the aquatic envi-ronment. KW - Abwasser KW - Ressourcen KW - microbial resistances KW - antimicrobial resistance genes KW - source separation KW - resource-oriented sanitation KW - UASB KW - OA-Publikationsfonds2021 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211202-45338 UR - www.mdpi.com/2073-4441/13/23/3342 VL - 2021 IS - Volume 13, issue 23, article 3342 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Londong, Jörg A1 - Barth, Marcus A1 - Söbke, Heinrich T1 - Reducing antimicrobial resistances by source separation of domestic wastewater JF - Frontiers in Environmental Health N2 - Antimicrobial resistances (AMR) are ranked among the top ten threats to public health and societal development worldwide. Toilet wastewater contained in domestic wastewater is a significant source of AMR entering the aquatic environment. The current commonly implemented combined sewer systems at times cause overflows during rain events, resulting in the discharge of untreated wastewater into the aquatic environment, thus promoting AMR. In this short research article, we describe an approach to transform combined sewer systems into source separation-modified combined sewer systems that separately treat toilet wastewater. We employ simulations for demonstrating that source separation-modified combined sewer systems reduce the emission of AMR- causing substances by up to 11.5 logarithm levels. Thus, source separation- modified combined sewer systems are amongst the most effective means of combating AMR. KEYWORDS KW - Allgemeinheit KW - Öffentlichkeit KW - Gesundheit KW - Kanal KW - Abwasser KW - Antibiotikum KW - Resistenz KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230403-49483 UR - https://www.frontiersin.org/articles/10.3389/fenvh.2023.1151898/full VL - 2023 IS - Volume 2, article 1151898 SP - 1 EP - 5 PB - Frontiers Media CY - Lausanne ER - TY - JOUR A1 - Aicher, Andreas A1 - Börmel, Melanie A1 - Londong, Jörg A1 - Beier, Silvio T1 - Vertical green system for gray water treatment: Analysis of the VertiKKA-module in a field test JF - Frontiers in Environmental Science N2 - This work presents a modular Vertical Green System (VGS) for gray water treatment, developed at the Bauhaus-Universität Weimar. The concept was transformed into a field study with four modules built and tested with synthetic gray water. Each module set contains a small and larger module with the same treatment substrate and was fed hourly. A combination of lightweight structural material and biochar of agricultural residues and wood chips was used as the treatment substrate. In this article, we present the first 18 weeks of operation. Regarding the treatment efficiency, the parameters chemical oxygen demand (COD), total phosphorous (TP), ortho-phosphate (ortho-P), total bound nitrogen (TNb), ammonium nitrogen (NH4-N), and nitrate nitrogen (NO3-N) were analyzed and are presented in this work. The results of the modules with agricultural residues are promising. Up to 92% COD reduction is stated in the data. The phosphate and nitrogen fractions are reduced significantly in these modules. By contrast, the modules with wood chips reduce only 67% of the incoming COD and respectively less regarding phosphates and the nitrogen fraction. KW - Grauwasser KW - Abwassertechnologie KW - vertical green system KW - grey water treatment KW - urban heat island effect KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230124-48840 UR - https://www.frontiersin.org/articles/10.3389/fenvs.2022.976005/full VL - 2022 IS - Volume 10 (2022), article 976005 SP - 1 EP - 7 PB - Frontiers Media CY - Lausanne ER -