TY - JOUR A1 - Völker, Conrad A1 - Beckmann, Julia A1 - Koehlmann, Sandra A1 - Kornadt, Oliver T1 - Occupant requirements in residential buildings – an empirical study and a theoretical model JF - Advances in Building Energy Research N2 - Occupant needs with regard to residential buildings are not well known due to a lack of representative scientific studies. To improve the lack of data, a large scale study was carried out using a Post Occupancy Evaluation of 1,416 building occupants. Several criteria describing the needs of occupants were evaluated with regard to their subjective level of relevance. Additionally, we investigated the degree to which deficiencies subjectively exist, and the degree to which occupants were able to accept them. From the data obtained, a hierarchy of criteria was created. It was found that building occupants ranked the physiological needs of air quality and thermal comfort the highest. Health hazards such as mould and contaminated building materials were unacceptable for occupants, while other deficiencies were more likely to be tolerated. Occupant satisfaction was also investigated. We found that most occupants can be classified as satisfied, although some differences do exist between different populations. To explain the relationship between the constructs of what we call relevance, acceptance, deficiency and satisfaction, we then created an explanatory model. Using correlation and regression analysis, the validity of the model was then confirmed by applying the collected data. The results of the study are both relevant in shaping further research and in providing guidance on how to maximize tenant satisfaction in real estate management. KW - Post Occupancy Evaluation KW - Gebäude KW - Benutzung KW - occupant requirements KW - occupant satisfaction KW - residential buildings KW - housing KW - questionnaire Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181015-38137 UR - https://www.tandfonline.com/doi/abs/10.1080/17512549.2012.749808 N1 - This is an Accepted Manuscript of an article published by Taylor & Francis in Advances in Building Energy Research on 29/01/2013, available online: https://www.tandfonline.com/doi/abs/10.1080/17512549.2012.749808. IS - 7 (1) SP - 35 EP - 50 ER - TY - JOUR A1 - Völker, Conrad A1 - Kornadt, Oliver A1 - Ostry, Milan T1 - Temperature reduction due to the application of phase change materials JF - Energy and Buildings N2 - Overheating is a major problem in many modern buildings due to the utilization of lightweight constructions with low heat storing capacity. A possible answer to this problem is the emplacement of phase change materials (PCM), thereby increasing the thermal mass of a building. These materials change their state of aggregation within a defined temperature range. Useful PCM for buildings show a phase transition from solid to liquid and vice versa. The thermal mass of the materials is increased by the latent heat. A modified gypsum plaster and a salt mixture were chosen as two materials for the study of their impact on room temperature reduction. For realistic investigations, test rooms were erected where measurements were carried out under different conditions such as temporary air change, alternate internal heat gains or clouding. The experimental data was finally reproduced by dint of a mathematical model. KW - Raumklima KW - Paraffin KW - Phasenumwandlung KW - Gebäude KW - Überhitzung KW - summer overheating in buildings KW - phase change materials KW - PCM KW - Paraffin KW - salt hydrate KW - numerical simulation KW - mathematical model KW - heat storage Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181025-38166 UR - https://www.sciencedirect.com/science/article/pii/S0378778807002034 N1 - The following article appeared in the journal Energy and Buildings 40 (5) 2008, 937‐944 and may be found at https://doi.org/10.1016/j.enbuild.2007.07.008. IS - 40, 5 SP - 937 EP - 944 ER - TY - CHAP A1 - Hoffmann, Sabine A1 - Kornadt, Oliver ED - Gürlebeck, Klaus ED - Könke, Carsten T1 - PHASENÜBERGANGSMATERIALIEN ALS PASSIVE WÄRMESPEICHER IN REVITALISIERUNGSOBJEKTEN N2 - Summer overheating in buildings is a common problem, especially in office buildings with large glazed facades, high internal loads and low thermal mass. Phase change materials (PCM) that undergo a phase transition in the temperature range of thermal comfort can add thermal mass without increasing the structural load of the building. The investigated PCM were micro-encapsulated and mixed into gypsum plaster. The experiments showed a reduction of indoor-temperature of up to 4 K when using a 3 cm layer of PCM-plaster with micro-encapsulated paraffin. The measurement results could validate a numerical model that is based on a temperature dependent function for heat capacity. Thermal building simulation showed that a 3 cm layer of PCM-plaster can help to fulfil German regulations concerning heat protection of buildings in summer for most office rooms. KW - Architektur KW - CAD KW - Computerunterstütztes Verfahren Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170327-29699 UR - http://euklid.bauing.uni-weimar.de/ikm2006/index.php_lang=de&what=papers.html ER - TY - CHAP A1 - Hartmann, Maria A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Das Potential von Fassadenbegrünungen zur Verringerung des Wärmeinseleffekts: Simulation eines Beispielquartiers T2 - Bauphysiktage Kaiserslautern 2022 N2 - Die Auswirkungen einer Fassadenbegrünung auf den Wärmeinseleffekt in Stuttgart wurde für eine Hitzeperiode numerisch simuliert und bewertet. Die Ergebnisse zeigten positive Auswirkungen innerhalb des Simulationsgebiets sowie eine geringe Fernwirkung auf benachbarte Stadtquartiere. Diese Änderungen können zur Verbesserung des thermischen Komforts im Außenraum beitragen. Eine reduzierte Temperatur der Außenoberfläche führt darüber hinaus auch zu einer geringeren Oberflächentemperatur der Wandinnenseite, welche die Innenraumtemperatur beeinflusst. Folglich kann die thermische Behaglichkeit auch im Innenraum erhöht werden. KW - Mikroklima KW - Envi-Met KW - Städtische Wärmeinsel KW - Fassadenbegrünung KW - Living-wall Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220713-46676 SN - 978-3-95974-176-7 SN - 2363-8206 CY - Kaiserslautern ER - TY - THES A1 - Hoffmann, Sabine T1 - Numerische und experimentelle Untersuchung von Phasenübergangsmaterialien zur Reduktion hoher sommerlicher Raumtemperaturen T1 - Numerical and experimental investigation on phase change materials to reduce high indoor temperatures during summer N2 - Moderne Büroarchitektur mit Räumen in Leichtbauweise und großen transparenten Fassa-denanteilen verschärft im Zusammenwirken mit hohen internen Lasten die Problematik der sommerlichen Überhitzung in Gebäuden. Phasenübergangsmaterialien (PCM: phase change materials) stellen eine interessante Möglichkeit dar, sommerliche Überhitzung in Gebäuden ohne aufwändige Anlagentechnik wie beispielsweise Klimaanlagen zu reduzieren. Der thermische Komfort in Räumen, die mit einem PCM-Putz ausgestattet sind, kann signifikant erhöht werden. Die Arbeit untersucht Anwendungsmöglichkeiten und Optimierungspotential eines PCM-Putzes auf experimentelle und numerische Weise. Zur Untersuchung des PCM-Putzes wurden materialtechnische und experimentelle sowie numerische und numerisch-analytische Methoden eingesetzt. Die Kenntnis der thermischen Parameter des PCM-Putzes ist unablässig für die Berechnung der möglichen Temperaturreduktionen. Zur Bestimmung der Latentwärme, des qualitativen Schmelz- und Erstarrungsprozesses sowie des Temperaturintervalls, in dem der Phasenübergang stattfindet, wurden Messungen mit einem Differential Scanning Calorimeter (DSC) durchgeführt. Für die experimentelle Untersuchung des PCM-Putzes wurden zwei identische Testräume in Leichtbauweise erstellt. Die Räume wurden im Verifikationsobjekt „Eiermannbau“ des Sonderforschungsbereiches SFB 524 der Bauhaus-Universität Weimar gemessen. Nach der Überprüfung, dass sich beide Räume thermisch gleich verhalten, wurde ein Raum mit dem PCM-Putz und der zweite Raum mit einem vergleichbaren Innenputz ohne PCM verputzt. Thermoelemente zur Temperaturmessung im Bauteil, an der Oberfläche und zur Raumlufttemperaturbestimmung wurden angebracht und mit einer Messwerterfassungsanlage verbunden. Der Verlauf der Außenlufttemperatur und die Globalstrahlung am Standort der Versuchsräume wurden aufgezeichnet, um einen Klimadatensatz zu erstellen. Für die Berechnung der Temperaturverteilung in einem PCM-Bauteil mit kontinuierlichem Phasenübergang existiert keine geschlossene analytische Lösung. Daher wurde ein numerischer Ansatz gewählt, bei dem der Phasenübergang im Temperaturbereich T1 bis T2 mit Hilfe einer temperaturabhängigen Wärmekapazität c(T) innerhalb der erweiterten Fou-rier’schen Wärmeleitungsgleichung dargestellt wird. Die Funktion c(T) wird auf Basis der DSC-Messungen bestimmt. Die Modellierung erfolgte mit einem Finite-Differenzen-Verfahren auf Grundlage der Fourier’schen Wärmeleitungsgleichung. Im Rahmen der Arbeit wurde ein PCM-Modul entwickelt, das in ein Gebäudesimulationsprogramm implementiert wurde. Mit dem neuen Modul lassen sich sowohl die Temperaturverläufe in einem PCM-Bauteil wie auch seine Wechselwirkung mit dem Raumklima darstellen. Eine Validierung des entwickelten PCM-Moduls anhand von zahlreichen experimentellen Daten der Versuchsräume wurde für das PCM-Modul erfolgreich durchgeführt. Sommerliche Überhitzungsstunden können durch PCM in Wand- und Deckenelementen deutlich reduziert werden. Der PCM-Putz eignet sich vor allem für Anwendungen in Leichtbauten wie z.B. moderne Büroräume. In Räumen, in denen bereits eine ausreichende thermische Masse vorhanden ist, ist die Temperaturreduktion durch PCM nur gering. Kann das PCM während der Nachtstunden nicht erstarren, erschöpft sich seine Fähigkeit zur Latentwärmespeicherung. Erhöhte Nachtlüftung führt bei entsprechend niedrigen Außentemperaturen zu höherem Wärmeübergang und kann damit zur besseren Entladung des PCM beitragen. Im Rahmen der Dissertation konnten Aussagen zur idealen Phasenübergangstemperatur in Abhängigkeit des verwendeten Materials und der Schichtdicke getroffen werden. Die Reduktion der Oberflächentemperaturen, die sich bei Einsatz eines PCM-Putzes unter geeigneten Randbedingungen ergibt, beträgt 2.0 - 3.5 K für eine Putzschicht von 1 cm und 3.0 - 5.0 K für eine Putzschicht von 3 cm. Diese Werte wurden sowohl numerisch als auch durch experimentelle Untersuchungen ermittelt. Die Reduktion der Lufttemperaturen aufgrund einer Konditionierung des Raumes mit PCM-Putz beträgt bei geeigneten thermischen Verhältnissen ca. 1.0 - 2.5 K für eine Putzschicht von 1 cm und 2.0 - 3.0 K für eine Putzschicht von 3 cm. Die operative Temperatur als wichtiger Komfortparameter kann durch den Einsatz des PCM-Putzes um bis zu 4 K gesenkt werden. Damit lässt sich mit Hilfe eines PCM-Putzes die thermische Behaglichkeit in einem Raum deutlich erhöhen. N2 - Modern office architecture with light-weight constructions, huge transparent facades and high internal heat loads aggravate the problem of overheating in buildings during summer. Phase Change Materials (PCM) are an interesting possibility to reduce overheating of buildings without expensive air-conditioning. The thermal comfort in rooms that are plastered with a PCM-plaster can be significantly increased. The thesis investigates fields of application and the potential for optimisation of a PCM-plaster in experimental and numerical way. For the investigation of the PCM-plaster investigations on the material properties were applied as well as experimental, numerical and analytical methods. The knowledge of the thermal properties of the PCM-plaster is indispensable to calculate the potential temperature reductions. Differential scanning measurements (DSC) were conducted to determine the latent heat of the material, the quality of melting and solidification and the temperature range in which the phase transition occurs. For the experimental investigation of the PCM-plaster two identical test rooms were erected as light-weight constructions. The rooms were monitored in the verification building “Eiermannbau” of the Collaborative Research Center (Sonderforschungsbereich) 524 of Bauhaus-Universität Weimar. After having ensured that both rooms behave thermally identically, one room was plastered with the PCM-plaster and the second one was plastered with a comparable conventional plaster. Thermocouples were added to measure air temperature and the readings went into a data acquisition. The course of ambient temperature and global radiation was measured as well to generate a climate data file. There is no closed analytical solution to calculate the temperature allocation in a PCM-material that shows a continuous phase transition. Therefore a numerical approach was chosen where the phase change process was described using a temperature dependent function of heat capacity c(T) in the temperature range of phase transition T1 to T2. The function c(T) is determined based on DSC-measurements. The numerical modelling was realised by modifying the Fourier equation of heat conduction with a finite difference approach. Within the thesis a PCM module was developed and implemented in a thermal building simulation software. With this new module the temperature allocation in a PCM-construction can be calculated as well as its interaction with the room. The validation of the developed PCM-module based on the readings of the test rooms was successful. Overheating hours during summer can be reduced significantly when using PCM in walls and ceilings. The PCM-plaster is especially useful for light-weight constructions as typical modern office rooms. In rooms where a significant thermal mass can be already found, the effect of PCM is more humble. If the PCM cannot solidify during night time its ability to store heat wears out. An increased ventilation during night time leads to a higher heat transfer if ambient temperatures are low enough and can therefore help the solidification of PCM. The thesis could give advices for the ideal phase change temperature depending on the material and on the layer thickness used. When using a PCM-plaster of 1 cm, surface temperatures can be lowered by 2.0 – 3.5 K under specific boundary conditions. The temperature reduction ranges from 3.0 -5.0 K for a PCM-plaster of 3 cm. These values were found in the numerical investigation as well as in the experiments. The reduction of room temperature due to the use of PCM-plaster was 1.0 – 2.5 K for a 1 cm layer and 2.0 – 3.0 for a 3 cm layer of PCM-plaster. The operative temperature as important comfort parameter was lowered by up to 4 K when using PCM-plaster. The thermal comfort in a room can thus be increased significantly with the investigated material. KW - Bauphysik KW - Phasenübergangsmaterialien KW - PCM-Putz KW - Latentwärmespeicher KW - sommerlicher Wärmeschutz KW - Gebäudesimulation ESP-r KW - phase change materials KW - PCM-plaster KW - latent heat storage KW - thermal protection KW - thermal building simulation Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20070709-8790 ER - TY - CHAP A1 - Geske, Mara A1 - Benz, Alexander A1 - Völker, Conrad ED - Kornadt, Oliver ED - Carrigan, Svenja ED - Hofmann, Markus ED - Völker, Conrad T1 - Anwendung georeferenzierter Bilddaten bei energetischen Quartiersanalysen T2 - Tagungsband Bauphysiktage Kaiserslautern 2022 N2 - Bei Analysen des Gebäudebestands im Quartierskontext werden zu Dokumentationszwecken viele Bilddaten erzeugt. Diese Daten sind im Nachhinein häufig keinen eindeutig genauen Standorten und Blickwinkeln auf das Bauwerk zuzuordnen. Insbesondere gilt dies für Ortsunkundige oder für Detailaufnahmen. Eine zusätzliche Herausforderung stellt die Aufnahme von Wärmebrücken- oder andersartigen Gebäudedetails durch Thermogramme dar. In der Praxis kommen hier oftmals analoge, fehleranfällige Lösungen zum Einsatz. Durch die Nutzung von Georeferenzierung kann diese Lücke geschlossen und eine eindeutige Kommunikation und Auswertung gewährleistet werden. Im Gegensatz zu den üblichen Kameras sind Smartphones nach Stand der Technik ausreichend ausgestattet, um neben Daten zu Standort auch die Orientierungswinkel einer Bildaufnahme zu dokumentieren. Die georefenzierten Bilder können auf Grundlage der in den sogenannten Exif-Daten mitgeschriebenen Informationen händisch in ein bestehendes Quartiersmodell integriert werden. Anhand eines universitären Musterquartiers wird die nutzerfreundliche Realisierung beispielhaft erprobt und auf ihre Potentiale zur Automatisierung in Python untersucht. Hierfür wurde ein bestehendes Quartiersmodell als geometrische Grundlage genutzt und um RGB-Bilder sowie Thermogramme erweitert. Das beschriebene Vorgehen wird im Rahmen der Anwendung auf seinen möglichen Einsatz im Rahmen einer energetischen Quartierserfassung sowie einer Bauschadensdokumentation untersucht. Mit dem vorliegenden Beitrag wird dem Nutzenden ein Werkzeug bereitgestellt, das die hochwertige Dokumentation einer Bestandserfassung, auch im Quartierskontext, ermöglicht. KW - Quartiersanalyse KW - Bilddaten KW - Bauphysik und Sanierung Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220617-46544 SN - 987-3-95974-176-7 SN - 2363-8206 PB - Eigenverlag der Technischen Universität Kaiserslautern CY - Kaiserslautern ER - TY - GEN A1 - Großmann, Felix T1 - Capturing Sheep With Minecraft N2 - Capturing Sheep With Minecraft befasst sich mit ausgewählten Problemen der Bauphysik und deren Umsetzung mithilfe des Computerspiels Minecraft. Es werden ausgewählte Probleme der Bauphysik in Minecraft abgebildet um diese Schülern und Studenten näher zu bringen. Es wurde ein Szenario in Minecraft entworfen welches durch entgegenwirken der abgebildeten Probleme, durch den Spieler gelöst werden soll. KW - Minecraft KW - Probleme KW - Bauphysik KW - Minecraft KW - Bauphysik KW - Probleme Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20121107-17530 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - RPRT A1 - Vogel, Albert A1 - Völker, Conrad A1 - Arnold, Jörg A1 - Schmidt, Jens A1 - Thurow, Torsten A1 - Braunes, Jörg A1 - Tonn, Christian A1 - Bode, Kay-André A1 - Baldy, Franziska A1 - Erfurt, Wolfgang A1 - Tatarin, René T1 - Methoden und Baustoffe zur nutzerorientierten Bausanierung. Schlussbericht zum InnoProfile Forschungsvorhaben N2 - Nutzerorientierte Bausanierung bedeutet eine gegenüber dem konventionellen Vorgehen deutlich verstärkte Ausrichtung des Planungs- und Sanierungsprozesses auf die Anforderungen und Bedürfnisse des zukünftigen Nutzers eines Gebäudes. Dies hat einerseits ein hochwertigeres Produkt zum Ergebnis, erfordert andererseits aber auch den Einsatz neuer Methoden und Baustoffe sowie ein vernetztes Zusammenarbeiten aller am Bauprozess Beteiligten. Der Fokus der Publikation liegt dabei auf den Bereichen, die eine hohe Relevanz für die nutzerorientierte Bausanierung aufweisen. Dabei handelt es sich insbesondere um: Computergestütztes Bauaufmaß und digitale Bauwerksmodellierung (BIM), bauphysikalische Methoden zur Optimierung von Energieeffizienz und Behaglichkeit bei der Sanierung von Bestandsgebäuden, zerstörungsfreie Untersuchungsmethoden im Rahmen einer substanzschonenden Bauzustandsanalyse und Entwicklung von Ergänzungsbaustoffen. Das Projekt nuBau ist eine Kooperation zwischen den Fakultäten Bauingenieurwesen und Architektur der Bauhaus-Universität Weimar. Die beteiligten Professuren sind: Bauphysik, Informatik in der Architektur, Polymere Werkstoffe und Werkstoffe des Bauens. T3 - Schriftenreihe der Professur Bauphysik - 5 KW - Nutzerorientierte Bausanierung KW - BIM KW - zerstörungsfreie Prüfung KW - bauphysikalische Methoden KW - Ergänzungsbaustoffe Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20130830-20229 UR - http://www.uni-weimar.de/cms/bauing/projekte/nubau/home.html SN - 978-3-86068-501-3 (Printausg.) ER - TY - JOUR A1 - Teitelbaum, Eric A1 - Alsaad, Hayder A1 - Aviv, Dorit A1 - Kim, Alexander A1 - Völker, Conrad A1 - Meggers, Forrest A1 - Pantelic, Jovan T1 - Addressing a systematic error correcting for free and mixed convection when measuring mean radiant temperature with globe thermometers JF - Scientific reports N2 - It is widely accepted that most people spend the majority of their lives indoors. Most individuals do not realize that while indoors, roughly half of heat exchange affecting their thermal comfort is in the form of thermal infrared radiation. We show that while researchers have been aware of its thermal comfort significance over the past century, systemic error has crept into the most common evaluation techniques, preventing adequate characterization of the radiant environment. Measuring and characterizing radiant heat transfer is a critical component of both building energy efficiency and occupant thermal comfort and productivity. Globe thermometers are typically used to measure mean radiant temperature (MRT), a commonly used metric for accounting for the radiant effects of an environment at a point in space. In this paper we extend previous field work to a controlled laboratory setting to (1) rigorously demonstrate that existing correction factors used in the American Society of Heating Ventilation and Air-conditioning Engineers (ASHRAE) Standard 55 or ISO7726 for using globe thermometers to quantify MRT are not sufficient; (2) develop a correction to improve the use of globe thermometers to address problems in the current standards; and (3) show that mean radiant temperature measured with ping-pong ball-sized globe thermometers is not reliable due to a stochastic convective bias. We also provide an analysis of the maximum precision of globe sensors themselves, a piece missing from the domain in contemporary literature. KW - Strahlungstemperatur KW - Mean radiant temperature KW - Globe thermometers KW - Indoor environment KW - Thermal comfort KW - Measurements KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220509-46363 UR - https://www.nature.com/articles/s41598-022-10172-5#citeas VL - 2022 IS - Volume 12, article 6473 PB - Springer Nature CY - London ER -