TY - RPRT A1 - Klemens, Laub A1 - Tetzner, Thomas T1 - Social Game Environmental Management N2 - Was ist soziales spielen? Warum ist es heutzutage so beliebt? Welche Mechaniken stecken hinter dem Erfolg? Weiterhin behandelt der Bericht eine neue Spielidee, die eine umwelttechnische Komponente für Bildungszwecke beinhaltet. N2 - What is social gaming? Why it is so popular nowadays? Which are the mechanics behind the success? The report deals also with the creative creation of a new game idea with an environment technical content for an educational matter. KW - Facebook KW - Facebook KW - social game KW - game mechanic Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20110905-15587 ER - TY - THES A1 - Jahn, Rosa T1 - Evaluation von Nutzerbedürfnissen in Wohngebäuden unter Berücksichtigung hygrothermischer Messdaten N2 - Evaluation von Nutzerbedürfnissen in Wohngebäuden unter Berücksichtigung hygrothermischer Messdaten KW - Raumklima KW - Bauphysik KW - Umfrage Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20130320-18758 N1 - Der Volltext-Zugang wurde im Zusammenhang mit der Klärung urheberrechtlicher Fragen mit sofortiger Wirkung gesperrt. ER - TY - THES A1 - Rothe, Christian T1 - Untersuchung diffuser kohärenter Schallfelder in Atrien N2 - In dieser Diplomarbeit werden – anhand eines Simulationsprogrammes – die diffusen Schallfelder in Atrien untersucht. Diesbezüglich standen Referenzobjekte in Berlin zur Verfügung. Es wurde untersucht, inwieweit sich die Raumgeometrie, die Volumina und die Absorptionseigenschaften der Umhüllungsflächen auf die Energieverteilung im Atriumsraum auswirken. Ziel der Arbeit ist es, Optimierungspotenziale aufzuzeigen und Lösungsvorschläge zu entwickeln, die zeigen, mit welchen Mitteln und Methoden die Raumakustik nachträglich verbessert werden kann. KW - Absorption KW - Absorptionskoeffizient KW - Raumakustik KW - Absorber KW - Absorberelement KW - Nachhall KW - Nachhallzeit KW - Klarheitsmaß KW - Deutlichkeit KW - Raumeindruck KW - Lautstärke KW - Diffusität Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-6786 N1 - Der Volltext-Zugang wurde im Zusammenhang mit der Klärung urheberrechtlicher Fragen mit sofortiger Wirkung gesperrt. ER - TY - THES A1 - Kuhne, Michael T1 - Modellierung des Energietransports durch Verglasungen T1 - Modelling of the transport of energy through thermal glazings N2 - Es werden sowohl analytische als auch numerische Verfahren zur Berechnung der Wärmeverluste von Verglasungen vorgestellt, wobei alle am Energietransport beteiligten Prozesse, die Wärmeleitung, die thermisch getriebenen Konvektionsströmungen und die infrarote Strahlungswechselwirkung, korrekt und vollständig berücksichtigt werden. Mit Hilfe numerischer Strömungssimulation werden Verglasungen systematisch hinsichtlich der Füllgasart, der Infrarotverspiegelung, der Einbaulage und des Scheibenabstandes sowie der Anzahl der Gaszwischenräume (Zwei-, Drei- und Vierscheiben-Verglasung) untersucht und verglichen. Die Abhängigkeit des k-Wertes von den Temperaturen der angrenzenden Klimate (Atmosphäre und Innenraum) wird dargestellt. N2 - The aim of this work is to calculate the heat losses of thermal glazings. Conduction, radiation and convection are described in detail. Both analytical and numerical approaches are presented. Using a program for Computational Fluid Dynamics (CFD) thermal glazings are investigated systematically. The influence of IR-reflecting coatings, kind of gas-filling, pane distance and number of panes is studied. Furthermore a dependence of the u-value on the temperature difference between room and atmosphere is described for certain gas-fillings. KW - Verglasung KW - Wärmeverlust KW - Strömungsfeld KW - Temperaturfeld KW - Finite-Volumen-Methode KW - Transportgleichung KW - Wärmeübertragung KW - Energietransport KW - Konvektion KW - Leitung KW - Strahlung KW - k-Wert KW - transport of energy KW - thermal glazings KW - conduction KW - radiation KW - convection Y1 - 1998 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20040220-458 ER - TY - THES A1 - Pastohr, Henry T1 - Thermodynamische Modellierung eines Aufwindkraftwerkes T1 - Thermodynamical modelling of an upwind power plant N2 - Die Energieversorgung auf der Erde wird zukünftig zu einem Problem. Bedingt ist dies durch eine fortschreitende Verknappung der natürlichen Ressourcen, wie Kohle, Gas und Öl sowie einer Zunahme der CO2-Konzentration und anderer Schadstoffe in der Atmosphäre. Regenerative Energiequellen müssen genutzt werden, um den steigenden Energiebedarf zu sichern. Eine interessante Möglichkeit zur Nutzung der Solarenergie stellt das Aufwindkraftwerk dar. Das Aufwindkraftwerk besteht aus einem Kamin, um den ein Glasdachkollektor auf dem Erdboden angeordnet ist. Am Fuße des Kamins befinden sich Turbinen und Generatoren. Die einfallende Solarenergie wird hauptsächlich über die Wechselwirkung mit dem Erdreich in thermische Energie, in kinetische Energie, in Rotationsenergie und in elektrische Energie umgewandelt. Das Ziel der Arbeit bestand in der physikalisch-mathematischen Modellierung, der genaueren Erkennung des Wirkprinzips und der Diskussion der Anlagenparameter Leistung und Wirkungsgrad. Im Rahmen dieser Aufgabe wurden dazu stationäre und instationäre Computational Fluid Dynamic (CFD) Modelle und stationäre und instationäre vereinfachte Modelle entwickelt, diskutiert und miteinander verglichen. Grundlegend neue Erkenntnisse wurden bei den Verläufen der Temperaturen im Kollektor, insbesondere der Erdoberflächentemperatur erreicht. Parameteranpassungen im Wärmeübergangsmodell und Widerstandsmodell führten für vier ausgewählte, stationäre Sonnenenergien auf eine gute Übereinstimmung zwischen den Ergebnissen (Temperaturhub, Druckentnahme, Leistung und Wirkungsgrad) des stationären, hybriden Modells und des stationären CFD-Modells. Weiterhin stimmen die lokalen Größen Wärmeübergangskoeffizient, Erdoberflächentemperatur, Lufttemperatur und Glasdachtemperatur gut zwischen den Modellen überein. Mit dem CFD Modell wurden der Prototyp und 3 Großkraftwerke berechnet. Mit dem entwickelten instationären FDM-Modell wurden erstmalig numerische Langzeitsimulationen (1 Jahr) durchgeführt. Zur Überprüfung des Modells wurden die Ergebnisse mit Messwerten aus Manzanares verglichen, wobei eine gute Übereinstimmung erreicht werden konnte. Das Verständnis für die stattfindenden thermodynamischen und strömungsmechanischen Prozesse in einem Aufwindkraftwerk konnte durch die Arbeit maßgeblich verbessert werden. N2 - The energy supply on our earth will become a problem in future. This is conditional by a shortage of the natural source, like coal, gas and oil, as well as an increase in the concentration of gasous CO2 in the atmosphere. Regenerative energy sources must be used more increasingly to saveguard the increasing energy consumption. Upwind power plants represent an interesting possibility for the use of solar energy. The upwind power plant consist of an collector, an chimney and one ore several turbines. The collector heats the air by the interaction with the ground. The glass reflects the infrared radiation of the ground. The Chimney provides a large density difference between the collector exit and the atmosphere. The goal of this work was the mathematical und physical modelling of the thermodynamics in and around an upwind power plant. Steady and unsteady CFD models and steady and unsteady simplified models were developed and compared. Basically new knowledge was reached at the courses of the temperatures in the collector. A very good agreement between the results of the steady hybrid model and the steady CFD model (temperature difference of the collector, pressure at the turbine, power and degree of effectiveness) could be found for four solar energies. Furthermore, the local values of heat-transfer coefficient, soil temperature, temperature of the fluid and the temperature of the glass roof compare very well beetwen the models. The prototyp manzanares and three large power plants were solved with the developed CFD model. Numeric long time simulations (1 year) were carried out for the first time with the developed unsteady Finite-Difference-Model. The model was compared with results of the project Manzanares. A good agreement was found. The knowledge of the thermodynamical und fluid dynamical processes in an upwind power plant were improved substantial by this work. KW - Aufwindkraftwerk KW - Numerische Strömungsmechanik KW - Mathematisches Modell KW - Thermodynamik KW - Sonnenenergie KW - Sonnenkollektor KW - upwind power plant KW - CFD KW - mathematical modelling KW - thermodynamics KW - solar energy Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20040803-867 ER - TY - JOUR A1 - Salandin, Andrea A1 - Arnold, Jörg A1 - Kornadt, Oliver T1 - Noise in an intensive care unit JF - The Journal of the Acoustical Society of America N2 - Patients and staff in hospitals are exposed to a complex sound environment with rather high noise levels. In intensive care units, the main noise sources are hospital staff on duty and medical equipment, which generates both operating noise and acoustic alarms. Although noise in most cases is produced during activities for the purpose of saving life, noise can induce significant changes in the depth and quality of sleep and negatively affect health in general. Results of a survey of hospital staff are presented as well as measurements in two German hospital wards: a standard two-bed room and a special Intermediate Care Unit (IMC-Unit), each in a different Intensive Care Unit (ICU). Sound pressure data were collected over a 48 hour period and converted into different levels (LAFeq, LAFmax, LAFmin, LAF 5%), as well as a rating level LAr, which is used to take tonality and impulsiveness into account. An analysis of the survey and the measured data, together with a comparison of thresholds of national and international regulations and standards describe the acoustic situation and its likely noise effects on staff and patients. KW - Lärm KW - Messung KW - Akustik KW - Intensivstation KW - Arbeitsplatz KW - noise KW - intensive care unit KW - acoustical measurement KW - Lärm KW - Intensivstation Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170713-32649 UR - http://dx.doi.org/10.1121/1.3655884 N1 - Copyright 2011 Acoustical Society of America. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the Acoustical Society of America. The following article appeared in The Journal of the Acoustical Society of America 130, 3754 (2011) and may be found at http://dx.doi.org/10.1121/1.3655884. VL - 2011 IS - 130 (6) SP - 3754 EP - 3760 ER - TY - CHAP A1 - Dokhanchi, Najmeh Sadat ED - Arnold, Jörg T1 - Acoustic travel time tomography: Applicability of an array of directional sound sources N2 - The technique of Acoustic travel-time TOMography (ATOM) allows for measuring the distribution of air temperatures throughout the entire room based on the determined sound-travel-times of early reflections, currently up to second order reflections. The number of detected early reflections in the room impulse response (RIR) which stands for the desired sound paths inside the room, has a significant impact on the resolution of reconstructed temperatures. This study investigates the possibility of utilizing an array of directional sound sources for ATOM measurements instead of a single omnidirectional loudspeaker used in the previous studies [1–3]. The developed measurement setup consists of two directional sound sources placed near the edge of the floor in the climate chamber of the Bauhaus-University Weimar and one omnidirectional receiver at center of the room near the ceiling. In order to compensate for the reduced number of sound paths when using directional sound sources, it is proposed to take high-energy early reflections up to third order into account. For this purpose, the simulated travel times up to third-order image sources were implemented in the image source model (ISM) algorithm, by which these early reflections can be detected effectively for air temperature reconstructions. To minimize the uncertainties of travel-times estimation due to the positioning of the sound transducers inside the room, measurements were conducted to determine the exact emitting point of the utilized sound source i.e. its acoustic center (AC). For these measurements, three types of excitation signals (MLS, linear and logarithmic chirp signals) with various frequency ranges were used considering that the acoustic center of a sound source is a frequency dependent parameter [4]. Furthermore, measurements were conducted to determine an optimum excitation signal based on the given condition of the ATOM measurement set-up which defines an optimum method for the RIR estimation correspondingly. Finally, the uncertainty of the measuring system utilizing an array of directional sound sources was analyzed. KW - Bauphysik KW - Akustische Laufzeit-Tomographie KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46589 UR - https://www.dega-akustik.de/publikationen/online-proceedings N1 - This conference paper has been submitted to the DAGA 2022. Thus, the original paper first is published in the "Fortschritte der Akustik - DAGA 2022" ER - TY - JOUR A1 - Völker, Conrad A1 - Mämpel, Silvio A1 - Kornadt, Oliver T1 - Measuring the human body’s micro‐climate using a thermal manikin JF - Indoor Air N2 - The human body is surrounded by a micro‐climate which results from its convective release of heat. In this study, the air temperature and flow velocity of this micro‐climate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the micro‐climate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the micro‐climate shape strongly depends not only on the body segment, but also on boundary conditions: the higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the air flow in the micro‐climate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient. KW - Raumklima KW - Mikroklima KW - Wärmeübertragung KW - Strömungsmechanik KW - thermal manikin KW - climate chamber KW - micro climate KW - heat transfer coefficient KW - CFD KW - thermography Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181025-38153 UR - https://onlinelibrary.wiley.com/doi/abs/10.1111/ina.12112 N1 - This is the peer reviewed version of the following article: "Measuring the human body’s micro‐climate using a thermal manikin", which has been published in final form at https://doi.org/10.1111/ina.12112. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. IS - 24, 6 SP - 567 EP - 579 ER - TY - CHAP A1 - Kiesel, Gerd A1 - Engels, Merit A1 - Völker, Conrad ED - Kornadt, Oliver ED - Carrigan, Svenja ED - Hofmann, Markus ED - Völker, Conrad T1 - Energetische Transformation im ländlichen Raum – Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells T2 - Schriftenreihe des Fachgebiets Bauphysik/Energetische Gebäudeoptimierung N2 - Kleine Kommunen im ländlichen Raum sind aufgrund ihrer oft eingeschränkten personellen und finanziellen Kapazitäten bisher eher sporadisch in den Themenfeldern Energieeffizienz und Erneuerbare Energien aktiv. Immer wieder stellt sich daher Frage, wie die Klimaschutzstrategien des Bundes und der Länder dort mit dem verfügbaren Personal kostengünstig realisierbar sind. Vor diesem Hintergrund wird ein Werkzeug entwickelt, mit dessen Hilfe der aktive Einstieg in diese Thematik mit geringen Aufwand und überwiegend barrierefrei möglich ist. Der Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells zur Erprobung und Umsetzung bezahlbarer Handlungsoptionen für Energieeinsparungen und effizienten Energieeinsatz im überwiegend ländlichen geprägten Raum ist der Schwerpunkt der Softwarelösung. Kommunen werden mit deren Hilfe in die Lage versetzt, in die notwendigen Prozesse der Energie- und Wärmewende einzusteigen. Dabei soll der modulare Aufbau die regulären Schritte notwendiger (integrierter) Planungsprozesse nicht vollständig ersetzen. Vielmehr können innerhalb der Online-Anwendung - überwiegend automatisiert - konkrete Maßnahmenvorschläge erstellt werden, die ein solides Fundament der künftigen energetischen Entwicklung der Kommunen darstellen. Für eine gezielte Validierung der Ergebnisse und der Ableitung potentieller Maßnahmen werden für die Erprobung Modellkommunen in Thüringen, Bayern und Hessen als Reallabore einbezogen. Das Tool steht bisher zunächst nur den beteiligten Modellkommunen zur Verfügung. Die entwickelte Softwarelösung soll künftig Schritt für Schritt allen interessierten Kommunen mit diversen Hilfsmitteln und einer Vielzahl anderer praktischer Bestandteile zur Verfügung gestellt werden. KW - Modellierung KW - Kommune KW - Energiewende KW - Transformation KW - ländlicher Raum Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220617-46566 SN - 978-3-95974-176-7 SN - 2363-8206 PB - Eigenverlag Technische Universität Kaiserslautern CY - Kaiserslautern ER - TY - THES A1 - Völker, Conrad T1 - Untersuchungen hinsichtlich des Einflusses von PCM auf die Raumlufttemperatur T1 - Impact of PCM on indoor temperatures N2 - Das Ziel der vorliegenden Diplomarbeit war es, „Untersuchungen hinsichtlich des Einflusses von Phase Change Materials auf die Raumlufttemperatur“ durchzuführen und anschließend die Ergebnisse auszuwerten. Dabei galt es, thermodynamische Grundlagen zu erläutern sowie den derzeitigen Stand der Forschung darzulegen. Dies wurde umfassend bearbeitet, allerdings kann hierbei aufgrund des Umfangs und der Vielfalt im Bereich der internationalen PCM-Forschung kein Anspruch auf Vollständigkeit erhoben werden. Ein Hauptteil dieser Arbeit bestand darin, den Versuchsaufbau der Referenzräume im Eiermann-Bau in Apolda als Grundlage für spätere Messungen detailliert zu beschreiben. Dabei wurde auf die gesamte Messanlage, die eingebrachten PCM sowie auf daraus resultierende physikalische Kenngrößen ausführlich eingegangen. Es galt, geometrische, chemische und physikalische Einflüsse einzuschätzen, aber auch Schwachstellen aufzudecken, um die später folgenden Messreihen exakt auswerten zu können. Als kritisch einzuschätzende Größe fiel dabei besonders das eingebrachte Salzgemisch auf, welches hinsichtlich des Schmelz- und Kristallisationsbereiches als kaum beurteilbar auffiel. Dies konnte auch nach mehreren Untersuchungen, hier ist insbesondere die dynamische Differenzkalorimetrie zu nennen, nicht hinreichend geklärt werden. Basierend auf diesen Erkenntnissen wurden vergleichende Messreihen durchgeführt, welche durch verschiedene Luftwechselraten gestaltet wurden. Im Maximum konnte dabei im PCM-konditionierten Raum eine Reduktion der Temperatur um 6 K erreicht werden. Dabei muss allerdings berücksichtigt werden, dass diese Differenz größtenteils auf die thermische Masse des Salzgemischs zurückgeführt werden kann. Eine abschließende Messung ohne Salzgemisch zeigte, dass aufgrund des latenten Wärmespeichervermögens des PCM-Putzes lediglich eine thermische Differenz von 2 K erreicht werden kann. Hinsichtlich der Luftwechselrate ist anzumerken, dass die erwartete, vergleichsweise zügige Auskühlung trotz Lüftung in der Praxis nicht nachvollzogen werden konnte. Zur Auswertung der gewonnenen Messwerte galt es, das am Lehrstuhl Bauphysik vorhandene mathematische Minimalmodell auf die am Objekt vorhandenen Randbedingungen anzupassen. Aus den Datenwolken der Atmosphärentemperatur sowie der Globalstrahlung mussten Funktionen approximiert werden, da diese äußeren Zwänge einen entscheidenden Einfluss auf den Verlauf der Innenraumtemperatur ausüben. Die Ergebnisse der Berechungen des Temperaturverlaufs können als zufrieden stellend betrachtet werden, jedoch wurde deutlich, dass ein genaues Nachstellen nicht möglich ist. Dies ist vor allem auf die Tatsache zurückzuführen, dass das Minimalmodell lediglich eine Beschreibung der wesentlichen Prozesse mathematisch abbildet. Eine kritische Auseinandersetzung hinsichtlich allgemeiner Standpunkte als auch der Anwendbarkeit auf die Referenzräume wurde abschließend diskutiert. KW - Latentwärmespeicher KW - Raumlufttemperatur KW - PCM KW - Phase Change Materials Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-6639 N1 - Der Volltext-Zugang wurde im Zusammenhang mit der Klärung urheberrechtlicher Fragen mit sofortiger Wirkung gesperrt. ER -