TY - JOUR A1 - Alsaad, Hayder A1 - Schälte, Gereon A1 - Schneeweiß, Mario A1 - Becher, Lia A1 - Pollack, Moritz A1 - Gena, Amayu Wakoya A1 - Schweiker, Marcel A1 - Hartmann, Maria A1 - Voelker, Conrad A1 - Rossaint, Rolf A1 - Irrgang, Matthias T1 - The Spread of Exhaled Air and Aerosols during Physical Exercise JF - Journal of Clinical Medicine N2 - Physical exercise demonstrates a special case of aerosol emission due to its associated elevated breathing rate. This can lead to a faster spread of airborne viruses and respiratory diseases. Therefore, this study investigates cross-infection risk during training. Twelve human subjects exercised on a cycle ergometer under three mask scenarios: no mask, surgical mask, and FFP2 mask. The emitted aerosols were measured in a grey room with a measurement setup equipped with an optical particle sensor. The spread of expired air was qualitatively and quantitatively assessed using schlieren imaging. Moreover, user satisfaction surveys were conducted to evaluate the comfort of wearing face masks during training. The results indicated that both surgical and FFP2 masks significantly reduced particles emission with a reduction efficiency of 87.1% and 91.3% of all particle sizes, respectively. However, compared to surgical masks, FFP2 masks provided a nearly tenfold greater reduction of the particle size range with long residence time in the air (0.3–0.5 μm). Furthermore, the investigated masks reduced exhalation spreading distances to less than 0.15 m and 0.1 m in the case of the surgical mask and FFP2 mask, respectively. User satisfaction solely differed with respect to perceived dyspnea between no mask and FFP2 mask conditions. KW - Sport KW - Training KW - Fahrradergometer KW - sport KW - training KW - cycle ergometer KW - schlieren imaging KW - particles concentration KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230208-49262 UR - https://www.mdpi.com/2077-0383/12/4/1300 VL - 2023 IS - Volume 12, issue 4, article 1300 PB - Basel CY - MDPI ER - TY - JOUR A1 - Vogel, Albert A1 - Arnold, Jörg A1 - Voelker, Conrad A1 - Kornadt, Oliver T1 - Data for sound pressure level prediction in lightweight constructions caused by structure-borne sound sources and their uncertainties JF - Data in Brief N2 - When predicting sound pressure levels induced by structure-borne sound sources and describing the sound propagation path through the building structure as exactly as possible, it is necessary to characterize the vibration behavior of the structure-borne sound sources. In this investigation, the characterization of structure-borne sound sources was performed using the two-stage method (TSM) described in EN 15657. Four different structure-borne sound sources were characterized and subsequently installed in a lightweight test stand. The resulting sound pressure levels in an adjacent receiving room were measured. In the second step, sound pressure levels were predicted according to EN 12354-5 based on the parameters of the structure-borne sound sources. Subsequently, the predicted and the measured sound pressure levels were compared to obtain reliable statements on the achievable accuracy when using source quantities determined by TSM with this prediction method. KW - Bauakustik KW - Körperschall KW - building acoustics KW - structure-borne sound KW - sound pressure level prediction KW - structure-borne sound sources KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230719-64114 UR - https://www.sciencedirect.com/science/article/pii/S2352340923004110?via%3Dihub VL - 2023 IS - Volume 48, June 2023, article 109292 SP - 1 EP - 16 PB - Elsevier CY - Amsterdam ER - TY - THES A1 - Dokhanchi, Najmeh Sadat T1 - Measurement of the Indoor Air Temperature Distribution using Acoustic Travel-Time Tomography N2 - One of the main criteria determining the thermal comfort of occupants is the air temperature. To monitor this parameter, a thermostat is traditionally mounted in the indoor environment for instance in office rooms in the workplaces, or directly on the radiator or in another location in a room. One of the drawbacks of this conventional method is the measurement at a certain location instead of the temperature distribution in the entire room including the occupant zone. As a result, the climatic conditions measured at the thermostat point may differ from those at the user's location. This not only negatively impacts the thermal comfort assessment but also leads to a waste of energy due to unnecessary heating and cooling. Moreover, for measuring the distribution of the air temperature under laboratory conditions, multiple thermal sensors should be installed in the area under investigation. This requires high effort in both installation and expense. To overcome the shortcomings of traditional sensors, Acoustic travel-time TOMography (ATOM) offers an alternative based on measuring the transmission sound velocity signals. The basis of the ATOM technique is the first-order dependency of the sound velocity on the medium's temperature. The average sound velocity, along the propagation paths, can be determined by travel-times estimation of a defined acoustic signal between transducers. After the travel-times collection, the room is divided into several volumetric grid cells, i.e. voxels, whose sizes are defined depending on the dimension of the room and the number of sound paths. Accordingly, the spatial air temperature in each voxel can be determined using a suitable tomographic algorithm. Recent studies indicate that despite the great potential of this technique to detect room climate, few experiments have been conducted. This thesis aims to develop the ATOM technique for indoor climatic applications while coupling the analysis methods of tomography and room acoustics. The method developed in this thesis uses high-energy early reflections in addition to the direct paths between transducers for travel time estimation. In this way, reflections can provide multiple sound paths that allow the room coverage to be maintained even when a few or even only one transmitter and receiver are used. In the development of the ATOM measurement system, several approaches have been employed, including the development of numerical methods and simulations and conducting experimental measurements, each of which has contributed to the improvement of the system's accuracy. In order to effectively separate the early reflections and ensure adequate coverage of the room with sound paths, a numerical method was developed based on the optimization of the coordinates of the sound transducers in the test room. The validation of the optimal positioning method shows that the reconstructed temperatures were significantly improved by placing the transducers at the optimal coordinates derived from the developed numerical method. The other numerical method developed is related to the selection of the travel times of the early reflections. Accordingly, the detection of the travel times has been improved by adjusting the lengths of the multiple analysis time-windows according to the individual travel times in the reflectogram of the room impulse response. This can reduce the probability of trapping faulty travel times in the analysis time-windows. The simulation model used in this thesis is based on the image source model (ISM) method for simulating the theoretical travel times of early reflection sound paths. The simulation model was developed to simulate the theoretical travel times up to third-order reflections. The empirical measurements were carried out in the climate lab of the Chair of Building Physics under different boundary conditions, i.e., combinations of different room air temperatures under both steady-state and transient conditions, and different measurement setups. With the measurements under controllable conditions in the climate lab, the validity of the developed numerical methods was confirmed. In this thesis, the performance of the ATOM measurement system was evaluated using two measurement setups. The setup for the initial investigations consists of an omnidirectional receiver and a near omnidirectional sound source, keeping the number of transducers as few as possible. This has led to accurately identify the sources of error that could occur in each part of the measuring system. The second measurement setup consists of two directional sound sources and one omnidirectional receiver. This arrangement of transducers allowed a higher number of well-detected travel times for tomography reconstruction, a better travel time estimation due to the directivity of the sound source, and better space utilization. Furthermore, this new measurement setup was tested to determine an optimal selection of the excitation signal. The results showed that for the utilized setup, a linear chirp signal with a frequency range of 200 - 4000 Hz and a signal duration of t = 1 s represents an optimal selection with respect to the reliability of the measured travel times and higher signal-to-noise ratio (SNR). To evaluate the performance of the measuring setups, the ATOM temperatures were always compared with the temperatures of high-resolution NTC thermistors with an accuracy of ±0.2 K. The entire measurement program, including acoustic measurements, simulation, signal processing, and visualization of measurement results are performed in MATLAB software. In addition, to reduce the uncertainty of the positioning of the transducers, the acoustic centre of the loudspeaker was determined experimentally for three types of excitation signals, namely MLS (maximum length sequence) signals with different lengths and duration, linear and logarithmic chirp signals with different defined frequency ranges. For this purpose, the climate lab was converted into a fully anechoic chamber by attaching absorption panels to the entire surfaces of the room. The measurement results indicated that the measurement of the acoustic centre of the sound source significantly reduces the displacement error of the transducer position. Moreover, to measure the air temperature in an occupied room, an algorithm was developed that can convert distorted signals into pure reference signals using an adaptive filter. The measurement results confirm the validity of the approach for a temperature interval of 4 K inside the climate lab. Accordingly, the accuracy of the reconstructed temperatures indicated that ATOM is very suitable for measuring the air temperature distribution in rooms. T3 - Schriftenreihe der Professur Bauphysik - 8 KW - Bauphysik KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230414-49567 SN - 978-3-00-075344-2 (print) ER - TY - JOUR A1 - Pollack, Moritz A1 - Lück, Andrea A1 - Wolf, Mario A1 - Kraft, Eckhard A1 - Völker, Conrad T1 - Energy and Business Synergy: Leveraging Biogenic Resources from Agriculture, Waste, and Wastewater in German Rural Areas JF - Sustainability N2 - The imperative to transform current energy provisions is widely acknowledged. However, scant attention has hitherto been directed toward rural municipalities and their innate resources, notably biogenic resources. In this paper, a methodological framework is developed to interconnect resources from waste, wastewater, and agricultural domains for energy utilization. This entails cataloging existing resources, delineating their potential via quantitative assessments utilizing diverse technologies, and encapsulating them in a conceptual model. The formulated models underwent iterative evaluation with engagement from diverse stakeholders. Consequently, 3 main concepts, complemented by 72 sub-concepts, were delineated, all fostering positive contributions to climate protection and providing heat supply in the rural study area. The outcomes’ replicability is underscored by the study area’s generic structure and the employed methodology. Through these inquiries, a framework for the requisite energy transition, with a pronounced emphasis on the coupling of waste, wastewater, and agriculture sectors in rural environments, is robustly analyzed. KW - Energiewende KW - Energieplanung KW - Abfallwirtschaft KW - organischer Abfall KW - Biomasse KW - Regionalentwicklung KW - biogene Abfallstoffe KW - Abwassermanagement KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20231222-65172 UR - https://www.mdpi.com/2071-1050/15/24/16573 VL - 2023 IS - volume 15, issue 24, article 16573 SP - 1 EP - 25 PB - MDPI CY - Basel ER - TY - CHAP A1 - Dokhanchi, Najmeh Sadat ED - Arnold, Jörg T1 - Acoustic travel time tomography: Applicability of an array of directional sound sources N2 - The technique of Acoustic travel-time TOMography (ATOM) allows for measuring the distribution of air temperatures throughout the entire room based on the determined sound-travel-times of early reflections, currently up to second order reflections. The number of detected early reflections in the room impulse response (RIR) which stands for the desired sound paths inside the room, has a significant impact on the resolution of reconstructed temperatures. This study investigates the possibility of utilizing an array of directional sound sources for ATOM measurements instead of a single omnidirectional loudspeaker used in the previous studies [1–3]. The developed measurement setup consists of two directional sound sources placed near the edge of the floor in the climate chamber of the Bauhaus-University Weimar and one omnidirectional receiver at center of the room near the ceiling. In order to compensate for the reduced number of sound paths when using directional sound sources, it is proposed to take high-energy early reflections up to third order into account. For this purpose, the simulated travel times up to third-order image sources were implemented in the image source model (ISM) algorithm, by which these early reflections can be detected effectively for air temperature reconstructions. To minimize the uncertainties of travel-times estimation due to the positioning of the sound transducers inside the room, measurements were conducted to determine the exact emitting point of the utilized sound source i.e. its acoustic center (AC). For these measurements, three types of excitation signals (MLS, linear and logarithmic chirp signals) with various frequency ranges were used considering that the acoustic center of a sound source is a frequency dependent parameter [4]. Furthermore, measurements were conducted to determine an optimum excitation signal based on the given condition of the ATOM measurement set-up which defines an optimum method for the RIR estimation correspondingly. Finally, the uncertainty of the measuring system utilizing an array of directional sound sources was analyzed. KW - Bauphysik KW - Akustische Laufzeit-Tomographie KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46589 UR - https://www.dega-akustik.de/publikationen/online-proceedings N1 - This conference paper has been submitted to the DAGA 2022. Thus, the original paper first is published in the "Fortschritte der Akustik - DAGA 2022" ER - TY - CHAP A1 - Kiesel, Gerd A1 - Engels, Merit A1 - Völker, Conrad ED - Kornadt, Oliver ED - Carrigan, Svenja ED - Hofmann, Markus ED - Völker, Conrad T1 - Energetische Transformation im ländlichen Raum – Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells T2 - Schriftenreihe des Fachgebiets Bauphysik/Energetische Gebäudeoptimierung N2 - Kleine Kommunen im ländlichen Raum sind aufgrund ihrer oft eingeschränkten personellen und finanziellen Kapazitäten bisher eher sporadisch in den Themenfeldern Energieeffizienz und Erneuerbare Energien aktiv. Immer wieder stellt sich daher Frage, wie die Klimaschutzstrategien des Bundes und der Länder dort mit dem verfügbaren Personal kostengünstig realisierbar sind. Vor diesem Hintergrund wird ein Werkzeug entwickelt, mit dessen Hilfe der aktive Einstieg in diese Thematik mit geringen Aufwand und überwiegend barrierefrei möglich ist. Der Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells zur Erprobung und Umsetzung bezahlbarer Handlungsoptionen für Energieeinsparungen und effizienten Energieeinsatz im überwiegend ländlichen geprägten Raum ist der Schwerpunkt der Softwarelösung. Kommunen werden mit deren Hilfe in die Lage versetzt, in die notwendigen Prozesse der Energie- und Wärmewende einzusteigen. Dabei soll der modulare Aufbau die regulären Schritte notwendiger (integrierter) Planungsprozesse nicht vollständig ersetzen. Vielmehr können innerhalb der Online-Anwendung - überwiegend automatisiert - konkrete Maßnahmenvorschläge erstellt werden, die ein solides Fundament der künftigen energetischen Entwicklung der Kommunen darstellen. Für eine gezielte Validierung der Ergebnisse und der Ableitung potentieller Maßnahmen werden für die Erprobung Modellkommunen in Thüringen, Bayern und Hessen als Reallabore einbezogen. Das Tool steht bisher zunächst nur den beteiligten Modellkommunen zur Verfügung. Die entwickelte Softwarelösung soll künftig Schritt für Schritt allen interessierten Kommunen mit diversen Hilfsmitteln und einer Vielzahl anderer praktischer Bestandteile zur Verfügung gestellt werden. KW - Modellierung KW - Kommune KW - Energiewende KW - Transformation KW - ländlicher Raum Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220617-46566 SN - 978-3-95974-176-7 SN - 2363-8206 PB - Eigenverlag Technische Universität Kaiserslautern CY - Kaiserslautern ER - TY - CHAP A1 - Hartmann, Maria A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Das Potential von Fassadenbegrünungen zur Verringerung des Wärmeinseleffekts: Simulation eines Beispielquartiers T2 - Bauphysiktage Kaiserslautern 2022 N2 - Die Auswirkungen einer Fassadenbegrünung auf den Wärmeinseleffekt in Stuttgart wurde für eine Hitzeperiode numerisch simuliert und bewertet. Die Ergebnisse zeigten positive Auswirkungen innerhalb des Simulationsgebiets sowie eine geringe Fernwirkung auf benachbarte Stadtquartiere. Diese Änderungen können zur Verbesserung des thermischen Komforts im Außenraum beitragen. Eine reduzierte Temperatur der Außenoberfläche führt darüber hinaus auch zu einer geringeren Oberflächentemperatur der Wandinnenseite, welche die Innenraumtemperatur beeinflusst. Folglich kann die thermische Behaglichkeit auch im Innenraum erhöht werden. KW - Mikroklima KW - Envi-Met KW - Städtische Wärmeinsel KW - Fassadenbegrünung KW - Living-wall Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220713-46676 SN - 978-3-95974-176-7 SN - 2363-8206 CY - Kaiserslautern ER - TY - CHAP A1 - Geske, Mara A1 - Benz, Alexander A1 - Völker, Conrad ED - Kornadt, Oliver ED - Carrigan, Svenja ED - Hofmann, Markus ED - Völker, Conrad T1 - Anwendung georeferenzierter Bilddaten bei energetischen Quartiersanalysen T2 - Tagungsband Bauphysiktage Kaiserslautern 2022 N2 - Bei Analysen des Gebäudebestands im Quartierskontext werden zu Dokumentationszwecken viele Bilddaten erzeugt. Diese Daten sind im Nachhinein häufig keinen eindeutig genauen Standorten und Blickwinkeln auf das Bauwerk zuzuordnen. Insbesondere gilt dies für Ortsunkundige oder für Detailaufnahmen. Eine zusätzliche Herausforderung stellt die Aufnahme von Wärmebrücken- oder andersartigen Gebäudedetails durch Thermogramme dar. In der Praxis kommen hier oftmals analoge, fehleranfällige Lösungen zum Einsatz. Durch die Nutzung von Georeferenzierung kann diese Lücke geschlossen und eine eindeutige Kommunikation und Auswertung gewährleistet werden. Im Gegensatz zu den üblichen Kameras sind Smartphones nach Stand der Technik ausreichend ausgestattet, um neben Daten zu Standort auch die Orientierungswinkel einer Bildaufnahme zu dokumentieren. Die georefenzierten Bilder können auf Grundlage der in den sogenannten Exif-Daten mitgeschriebenen Informationen händisch in ein bestehendes Quartiersmodell integriert werden. Anhand eines universitären Musterquartiers wird die nutzerfreundliche Realisierung beispielhaft erprobt und auf ihre Potentiale zur Automatisierung in Python untersucht. Hierfür wurde ein bestehendes Quartiersmodell als geometrische Grundlage genutzt und um RGB-Bilder sowie Thermogramme erweitert. Das beschriebene Vorgehen wird im Rahmen der Anwendung auf seinen möglichen Einsatz im Rahmen einer energetischen Quartierserfassung sowie einer Bauschadensdokumentation untersucht. Mit dem vorliegenden Beitrag wird dem Nutzenden ein Werkzeug bereitgestellt, das die hochwertige Dokumentation einer Bestandserfassung, auch im Quartierskontext, ermöglicht. KW - Quartiersanalyse KW - Bilddaten KW - Bauphysik und Sanierung Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220617-46544 SN - 987-3-95974-176-7 SN - 2363-8206 PB - Eigenverlag der Technischen Universität Kaiserslautern CY - Kaiserslautern ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Teitelbaum, Eric A1 - Alsaad, Hayder A1 - Aviv, Dorit A1 - Kim, Alexander A1 - Völker, Conrad A1 - Meggers, Forrest A1 - Pantelic, Jovan T1 - Addressing a systematic error correcting for free and mixed convection when measuring mean radiant temperature with globe thermometers JF - Scientific reports N2 - It is widely accepted that most people spend the majority of their lives indoors. Most individuals do not realize that while indoors, roughly half of heat exchange affecting their thermal comfort is in the form of thermal infrared radiation. We show that while researchers have been aware of its thermal comfort significance over the past century, systemic error has crept into the most common evaluation techniques, preventing adequate characterization of the radiant environment. Measuring and characterizing radiant heat transfer is a critical component of both building energy efficiency and occupant thermal comfort and productivity. Globe thermometers are typically used to measure mean radiant temperature (MRT), a commonly used metric for accounting for the radiant effects of an environment at a point in space. In this paper we extend previous field work to a controlled laboratory setting to (1) rigorously demonstrate that existing correction factors used in the American Society of Heating Ventilation and Air-conditioning Engineers (ASHRAE) Standard 55 or ISO7726 for using globe thermometers to quantify MRT are not sufficient; (2) develop a correction to improve the use of globe thermometers to address problems in the current standards; and (3) show that mean radiant temperature measured with ping-pong ball-sized globe thermometers is not reliable due to a stochastic convective bias. We also provide an analysis of the maximum precision of globe sensors themselves, a piece missing from the domain in contemporary literature. KW - Strahlungstemperatur KW - Mean radiant temperature KW - Globe thermometers KW - Indoor environment KW - Thermal comfort KW - Measurements KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220509-46363 UR - https://www.nature.com/articles/s41598-022-10172-5#citeas VL - 2022 IS - Volume 12, article 6473 PB - Springer Nature CY - London ER -