TY - JOUR A1 - Völker, Conrad A1 - Beckmann, Julia A1 - Koehlmann, Sandra A1 - Kornadt, Oliver T1 - Occupant requirements in residential buildings – an empirical study and a theoretical model JF - Advances in Building Energy Research N2 - Occupant needs with regard to residential buildings are not well known due to a lack of representative scientific studies. To improve the lack of data, a large scale study was carried out using a Post Occupancy Evaluation of 1,416 building occupants. Several criteria describing the needs of occupants were evaluated with regard to their subjective level of relevance. Additionally, we investigated the degree to which deficiencies subjectively exist, and the degree to which occupants were able to accept them. From the data obtained, a hierarchy of criteria was created. It was found that building occupants ranked the physiological needs of air quality and thermal comfort the highest. Health hazards such as mould and contaminated building materials were unacceptable for occupants, while other deficiencies were more likely to be tolerated. Occupant satisfaction was also investigated. We found that most occupants can be classified as satisfied, although some differences do exist between different populations. To explain the relationship between the constructs of what we call relevance, acceptance, deficiency and satisfaction, we then created an explanatory model. Using correlation and regression analysis, the validity of the model was then confirmed by applying the collected data. The results of the study are both relevant in shaping further research and in providing guidance on how to maximize tenant satisfaction in real estate management. KW - Post Occupancy Evaluation KW - Gebäude KW - Benutzung KW - occupant requirements KW - occupant satisfaction KW - residential buildings KW - housing KW - questionnaire Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181015-38137 UR - https://www.tandfonline.com/doi/abs/10.1080/17512549.2012.749808 N1 - This is an Accepted Manuscript of an article published by Taylor & Francis in Advances in Building Energy Research on 29/01/2013, available online: https://www.tandfonline.com/doi/abs/10.1080/17512549.2012.749808. IS - 7 (1) SP - 35 EP - 50 ER - TY - THES A1 - Hoffmann, Sabine T1 - Numerische und experimentelle Untersuchung von Phasenübergangsmaterialien zur Reduktion hoher sommerlicher Raumtemperaturen T1 - Numerical and experimental investigation on phase change materials to reduce high indoor temperatures during summer N2 - Moderne Büroarchitektur mit Räumen in Leichtbauweise und großen transparenten Fassa-denanteilen verschärft im Zusammenwirken mit hohen internen Lasten die Problematik der sommerlichen Überhitzung in Gebäuden. Phasenübergangsmaterialien (PCM: phase change materials) stellen eine interessante Möglichkeit dar, sommerliche Überhitzung in Gebäuden ohne aufwändige Anlagentechnik wie beispielsweise Klimaanlagen zu reduzieren. Der thermische Komfort in Räumen, die mit einem PCM-Putz ausgestattet sind, kann signifikant erhöht werden. Die Arbeit untersucht Anwendungsmöglichkeiten und Optimierungspotential eines PCM-Putzes auf experimentelle und numerische Weise. Zur Untersuchung des PCM-Putzes wurden materialtechnische und experimentelle sowie numerische und numerisch-analytische Methoden eingesetzt. Die Kenntnis der thermischen Parameter des PCM-Putzes ist unablässig für die Berechnung der möglichen Temperaturreduktionen. Zur Bestimmung der Latentwärme, des qualitativen Schmelz- und Erstarrungsprozesses sowie des Temperaturintervalls, in dem der Phasenübergang stattfindet, wurden Messungen mit einem Differential Scanning Calorimeter (DSC) durchgeführt. Für die experimentelle Untersuchung des PCM-Putzes wurden zwei identische Testräume in Leichtbauweise erstellt. Die Räume wurden im Verifikationsobjekt „Eiermannbau“ des Sonderforschungsbereiches SFB 524 der Bauhaus-Universität Weimar gemessen. Nach der Überprüfung, dass sich beide Räume thermisch gleich verhalten, wurde ein Raum mit dem PCM-Putz und der zweite Raum mit einem vergleichbaren Innenputz ohne PCM verputzt. Thermoelemente zur Temperaturmessung im Bauteil, an der Oberfläche und zur Raumlufttemperaturbestimmung wurden angebracht und mit einer Messwerterfassungsanlage verbunden. Der Verlauf der Außenlufttemperatur und die Globalstrahlung am Standort der Versuchsräume wurden aufgezeichnet, um einen Klimadatensatz zu erstellen. Für die Berechnung der Temperaturverteilung in einem PCM-Bauteil mit kontinuierlichem Phasenübergang existiert keine geschlossene analytische Lösung. Daher wurde ein numerischer Ansatz gewählt, bei dem der Phasenübergang im Temperaturbereich T1 bis T2 mit Hilfe einer temperaturabhängigen Wärmekapazität c(T) innerhalb der erweiterten Fou-rier’schen Wärmeleitungsgleichung dargestellt wird. Die Funktion c(T) wird auf Basis der DSC-Messungen bestimmt. Die Modellierung erfolgte mit einem Finite-Differenzen-Verfahren auf Grundlage der Fourier’schen Wärmeleitungsgleichung. Im Rahmen der Arbeit wurde ein PCM-Modul entwickelt, das in ein Gebäudesimulationsprogramm implementiert wurde. Mit dem neuen Modul lassen sich sowohl die Temperaturverläufe in einem PCM-Bauteil wie auch seine Wechselwirkung mit dem Raumklima darstellen. Eine Validierung des entwickelten PCM-Moduls anhand von zahlreichen experimentellen Daten der Versuchsräume wurde für das PCM-Modul erfolgreich durchgeführt. Sommerliche Überhitzungsstunden können durch PCM in Wand- und Deckenelementen deutlich reduziert werden. Der PCM-Putz eignet sich vor allem für Anwendungen in Leichtbauten wie z.B. moderne Büroräume. In Räumen, in denen bereits eine ausreichende thermische Masse vorhanden ist, ist die Temperaturreduktion durch PCM nur gering. Kann das PCM während der Nachtstunden nicht erstarren, erschöpft sich seine Fähigkeit zur Latentwärmespeicherung. Erhöhte Nachtlüftung führt bei entsprechend niedrigen Außentemperaturen zu höherem Wärmeübergang und kann damit zur besseren Entladung des PCM beitragen. Im Rahmen der Dissertation konnten Aussagen zur idealen Phasenübergangstemperatur in Abhängigkeit des verwendeten Materials und der Schichtdicke getroffen werden. Die Reduktion der Oberflächentemperaturen, die sich bei Einsatz eines PCM-Putzes unter geeigneten Randbedingungen ergibt, beträgt 2.0 - 3.5 K für eine Putzschicht von 1 cm und 3.0 - 5.0 K für eine Putzschicht von 3 cm. Diese Werte wurden sowohl numerisch als auch durch experimentelle Untersuchungen ermittelt. Die Reduktion der Lufttemperaturen aufgrund einer Konditionierung des Raumes mit PCM-Putz beträgt bei geeigneten thermischen Verhältnissen ca. 1.0 - 2.5 K für eine Putzschicht von 1 cm und 2.0 - 3.0 K für eine Putzschicht von 3 cm. Die operative Temperatur als wichtiger Komfortparameter kann durch den Einsatz des PCM-Putzes um bis zu 4 K gesenkt werden. Damit lässt sich mit Hilfe eines PCM-Putzes die thermische Behaglichkeit in einem Raum deutlich erhöhen. N2 - Modern office architecture with light-weight constructions, huge transparent facades and high internal heat loads aggravate the problem of overheating in buildings during summer. Phase Change Materials (PCM) are an interesting possibility to reduce overheating of buildings without expensive air-conditioning. The thermal comfort in rooms that are plastered with a PCM-plaster can be significantly increased. The thesis investigates fields of application and the potential for optimisation of a PCM-plaster in experimental and numerical way. For the investigation of the PCM-plaster investigations on the material properties were applied as well as experimental, numerical and analytical methods. The knowledge of the thermal properties of the PCM-plaster is indispensable to calculate the potential temperature reductions. Differential scanning measurements (DSC) were conducted to determine the latent heat of the material, the quality of melting and solidification and the temperature range in which the phase transition occurs. For the experimental investigation of the PCM-plaster two identical test rooms were erected as light-weight constructions. The rooms were monitored in the verification building “Eiermannbau” of the Collaborative Research Center (Sonderforschungsbereich) 524 of Bauhaus-Universität Weimar. After having ensured that both rooms behave thermally identically, one room was plastered with the PCM-plaster and the second one was plastered with a comparable conventional plaster. Thermocouples were added to measure air temperature and the readings went into a data acquisition. The course of ambient temperature and global radiation was measured as well to generate a climate data file. There is no closed analytical solution to calculate the temperature allocation in a PCM-material that shows a continuous phase transition. Therefore a numerical approach was chosen where the phase change process was described using a temperature dependent function of heat capacity c(T) in the temperature range of phase transition T1 to T2. The function c(T) is determined based on DSC-measurements. The numerical modelling was realised by modifying the Fourier equation of heat conduction with a finite difference approach. Within the thesis a PCM module was developed and implemented in a thermal building simulation software. With this new module the temperature allocation in a PCM-construction can be calculated as well as its interaction with the room. The validation of the developed PCM-module based on the readings of the test rooms was successful. Overheating hours during summer can be reduced significantly when using PCM in walls and ceilings. The PCM-plaster is especially useful for light-weight constructions as typical modern office rooms. In rooms where a significant thermal mass can be already found, the effect of PCM is more humble. If the PCM cannot solidify during night time its ability to store heat wears out. An increased ventilation during night time leads to a higher heat transfer if ambient temperatures are low enough and can therefore help the solidification of PCM. The thesis could give advices for the ideal phase change temperature depending on the material and on the layer thickness used. When using a PCM-plaster of 1 cm, surface temperatures can be lowered by 2.0 – 3.5 K under specific boundary conditions. The temperature reduction ranges from 3.0 -5.0 K for a PCM-plaster of 3 cm. These values were found in the numerical investigation as well as in the experiments. The reduction of room temperature due to the use of PCM-plaster was 1.0 – 2.5 K for a 1 cm layer and 2.0 – 3.0 for a 3 cm layer of PCM-plaster. The operative temperature as important comfort parameter was lowered by up to 4 K when using PCM-plaster. The thermal comfort in a room can thus be increased significantly with the investigated material. KW - Bauphysik KW - Phasenübergangsmaterialien KW - PCM-Putz KW - Latentwärmespeicher KW - sommerlicher Wärmeschutz KW - Gebäudesimulation ESP-r KW - phase change materials KW - PCM-plaster KW - latent heat storage KW - thermal protection KW - thermal building simulation Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20070709-8790 ER - TY - JOUR A1 - Salandin, Andrea A1 - Arnold, Jörg A1 - Kornadt, Oliver T1 - Noise in an intensive care unit JF - The Journal of the Acoustical Society of America N2 - Patients and staff in hospitals are exposed to a complex sound environment with rather high noise levels. In intensive care units, the main noise sources are hospital staff on duty and medical equipment, which generates both operating noise and acoustic alarms. Although noise in most cases is produced during activities for the purpose of saving life, noise can induce significant changes in the depth and quality of sleep and negatively affect health in general. Results of a survey of hospital staff are presented as well as measurements in two German hospital wards: a standard two-bed room and a special Intermediate Care Unit (IMC-Unit), each in a different Intensive Care Unit (ICU). Sound pressure data were collected over a 48 hour period and converted into different levels (LAFeq, LAFmax, LAFmin, LAF 5%), as well as a rating level LAr, which is used to take tonality and impulsiveness into account. An analysis of the survey and the measured data, together with a comparison of thresholds of national and international regulations and standards describe the acoustic situation and its likely noise effects on staff and patients. KW - Lärm KW - Messung KW - Akustik KW - Intensivstation KW - Arbeitsplatz KW - noise KW - intensive care unit KW - acoustical measurement KW - Lärm KW - Intensivstation Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170713-32649 UR - http://dx.doi.org/10.1121/1.3655884 N1 - Copyright 2011 Acoustical Society of America. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the Acoustical Society of America. The following article appeared in The Journal of the Acoustical Society of America 130, 3754 (2011) and may be found at http://dx.doi.org/10.1121/1.3655884. VL - 2011 IS - 130 (6) SP - 3754 EP - 3760 ER - TY - THES A1 - Kuhne, Michael T1 - Modellierung des Energietransports durch Verglasungen T1 - Modelling of the transport of energy through thermal glazings N2 - Es werden sowohl analytische als auch numerische Verfahren zur Berechnung der Wärmeverluste von Verglasungen vorgestellt, wobei alle am Energietransport beteiligten Prozesse, die Wärmeleitung, die thermisch getriebenen Konvektionsströmungen und die infrarote Strahlungswechselwirkung, korrekt und vollständig berücksichtigt werden. Mit Hilfe numerischer Strömungssimulation werden Verglasungen systematisch hinsichtlich der Füllgasart, der Infrarotverspiegelung, der Einbaulage und des Scheibenabstandes sowie der Anzahl der Gaszwischenräume (Zwei-, Drei- und Vierscheiben-Verglasung) untersucht und verglichen. Die Abhängigkeit des k-Wertes von den Temperaturen der angrenzenden Klimate (Atmosphäre und Innenraum) wird dargestellt. N2 - The aim of this work is to calculate the heat losses of thermal glazings. Conduction, radiation and convection are described in detail. Both analytical and numerical approaches are presented. Using a program for Computational Fluid Dynamics (CFD) thermal glazings are investigated systematically. The influence of IR-reflecting coatings, kind of gas-filling, pane distance and number of panes is studied. Furthermore a dependence of the u-value on the temperature difference between room and atmosphere is described for certain gas-fillings. KW - Verglasung KW - Wärmeverlust KW - Strömungsfeld KW - Temperaturfeld KW - Finite-Volumen-Methode KW - Transportgleichung KW - Wärmeübertragung KW - Energietransport KW - Konvektion KW - Leitung KW - Strahlung KW - k-Wert KW - transport of energy KW - thermal glazings KW - conduction KW - radiation KW - convection Y1 - 1998 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20040220-458 ER - TY - RPRT A1 - Vogel, Albert A1 - Völker, Conrad A1 - Arnold, Jörg A1 - Schmidt, Jens A1 - Thurow, Torsten A1 - Braunes, Jörg A1 - Tonn, Christian A1 - Bode, Kay-André A1 - Baldy, Franziska A1 - Erfurt, Wolfgang A1 - Tatarin, René T1 - Methoden und Baustoffe zur nutzerorientierten Bausanierung. Schlussbericht zum InnoProfile Forschungsvorhaben N2 - Nutzerorientierte Bausanierung bedeutet eine gegenüber dem konventionellen Vorgehen deutlich verstärkte Ausrichtung des Planungs- und Sanierungsprozesses auf die Anforderungen und Bedürfnisse des zukünftigen Nutzers eines Gebäudes. Dies hat einerseits ein hochwertigeres Produkt zum Ergebnis, erfordert andererseits aber auch den Einsatz neuer Methoden und Baustoffe sowie ein vernetztes Zusammenarbeiten aller am Bauprozess Beteiligten. Der Fokus der Publikation liegt dabei auf den Bereichen, die eine hohe Relevanz für die nutzerorientierte Bausanierung aufweisen. Dabei handelt es sich insbesondere um: Computergestütztes Bauaufmaß und digitale Bauwerksmodellierung (BIM), bauphysikalische Methoden zur Optimierung von Energieeffizienz und Behaglichkeit bei der Sanierung von Bestandsgebäuden, zerstörungsfreie Untersuchungsmethoden im Rahmen einer substanzschonenden Bauzustandsanalyse und Entwicklung von Ergänzungsbaustoffen. Das Projekt nuBau ist eine Kooperation zwischen den Fakultäten Bauingenieurwesen und Architektur der Bauhaus-Universität Weimar. Die beteiligten Professuren sind: Bauphysik, Informatik in der Architektur, Polymere Werkstoffe und Werkstoffe des Bauens. T3 - Schriftenreihe der Professur Bauphysik - 5 KW - Nutzerorientierte Bausanierung KW - BIM KW - zerstörungsfreie Prüfung KW - bauphysikalische Methoden KW - Ergänzungsbaustoffe Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20130830-20229 UR - http://www.uni-weimar.de/cms/bauing/projekte/nubau/home.html SN - 978-3-86068-501-3 (Printausg.) ER - TY - INPR A1 - Vogel, Albert A1 - Völker, Conrad A1 - Bode, Matthias A1 - Marx, Steffen T1 - Messung und Simulation der Erwärmung von ermüdungsbeanspruchten Betonprobekörpern T2 - Bauphysik N2 - Im vorliegenden Beitrag werden Messungen und Berechnungen vorgestellt, die die Temperaturentwicklung in Betonzylindern aufgrund zyklischer Beanspruchung genau beschreiben. Die Messungen wurden in einem Versuchsstand, die Berechnungen im FEM-Programm ANSYS durchgeführt. Mit Hilfe der Temperaturmessungen konnten die Simulationen für die Temperaturentwicklung der Betonzylinder mit der verwendeten Betonrezeptur validiert werden. Die Untersuchungen lassen den Schluss zu, dass bei zyklischer Probekörperbelastung und der einhergehenden Probekörperdehnung Energie dissipiert wird und diese maßgeblich für die Erwärmung der Probe verantwortlich ist. N2 - This paper presents measurements and simulations that describe the temperature development in concrete cylinders due to cyclic loading. The measurements were carried out in a test stand, the simulations in the FEM program ANSYS. The simulations of the temperature development in the concrete cylinders with the used concrete recipe were validated using the temperature measurements. The investigations lead to the conclusion that energy is dissipated during cyclic test specimen loading and the accompanying test specimen elongation and that this is mainly responsible for the heating of the specimen. KW - zyklische Beanspruchung KW - Ermüdung KW - Dissipation KW - zyklische Beanspruchung KW - Ermüdung KW - Dissipation KW - cyclic load KW - fatigue Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200425-41471 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.201900031 N1 - This is the pre-peer reviewed version of the following article: hhttps://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.201900031, which has been published in final form at https://doi.org/10.1002/bapi.201900031. VL - 2020 IS - Volume 42, Issue 2 SP - 86 EP - 93 PB - John Wiley and Sons ER - TY - JOUR A1 - Völker, Conrad A1 - Mämpel, Silvio A1 - Kornadt, Oliver T1 - Measuring the human body’s micro‐climate using a thermal manikin JF - Indoor Air N2 - The human body is surrounded by a micro‐climate which results from its convective release of heat. In this study, the air temperature and flow velocity of this micro‐climate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the micro‐climate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the micro‐climate shape strongly depends not only on the body segment, but also on boundary conditions: the higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the air flow in the micro‐climate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient. KW - Raumklima KW - Mikroklima KW - Wärmeübertragung KW - Strömungsmechanik KW - thermal manikin KW - climate chamber KW - micro climate KW - heat transfer coefficient KW - CFD KW - thermography Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181025-38153 UR - https://onlinelibrary.wiley.com/doi/abs/10.1111/ina.12112 N1 - This is the peer reviewed version of the following article: "Measuring the human body’s micro‐climate using a thermal manikin", which has been published in final form at https://doi.org/10.1111/ina.12112. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. IS - 24, 6 SP - 567 EP - 579 ER - TY - CHAP A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Measuring and visualizing the flow supplied by personalized ventilation T2 - Proceedings Book Roomvent 2020 N2 - This study investigates the flow supplied by personalized ventilation (PV) by means of anemometer measurements and schlieren visualization. The study was conducted using a thermal manikin to simulate a seated occupant facing a PV outlet. Air velocity was measured at multiple points in the flow field; the collected velocity values were used to calculate the turbulence intensity. Results indicated that PV was supplying air with low turbulence intensity that was able to penetrate the convective boundary layer of the manikin to supply clean air for inhalation. The convective boundary layer, however, obstructed the supplied flow and reduced its velocity by a total of 0.26 m/s. The PV flow preserved its value until about 10 cm from the face where velocity started to drop. Further investigations were conducted to test a PV diffuser with a relatively large outlet diameter (18 cm). This diffuser was developed using 3d-modelling and 3d-printing. The diffuser successfully distributed the flow over the larger outlet area. However, the supplied velocity and turbulence fields were not uniform across the section. KW - Belüftung KW - Luftqualität KW - Personalized ventilation KW - Schlieren imaging KW - Air quality KW - Thermal manikin Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46573 CY - Turin, Italy ER - TY - THES A1 - Dokhanchi, Najmeh Sadat T1 - Measurement of the Indoor Air Temperature Distribution using Acoustic Travel-Time Tomography N2 - One of the main criteria determining the thermal comfort of occupants is the air temperature. To monitor this parameter, a thermostat is traditionally mounted in the indoor environment for instance in office rooms in the workplaces, or directly on the radiator or in another location in a room. One of the drawbacks of this conventional method is the measurement at a certain location instead of the temperature distribution in the entire room including the occupant zone. As a result, the climatic conditions measured at the thermostat point may differ from those at the user's location. This not only negatively impacts the thermal comfort assessment but also leads to a waste of energy due to unnecessary heating and cooling. Moreover, for measuring the distribution of the air temperature under laboratory conditions, multiple thermal sensors should be installed in the area under investigation. This requires high effort in both installation and expense. To overcome the shortcomings of traditional sensors, Acoustic travel-time TOMography (ATOM) offers an alternative based on measuring the transmission sound velocity signals. The basis of the ATOM technique is the first-order dependency of the sound velocity on the medium's temperature. The average sound velocity, along the propagation paths, can be determined by travel-times estimation of a defined acoustic signal between transducers. After the travel-times collection, the room is divided into several volumetric grid cells, i.e. voxels, whose sizes are defined depending on the dimension of the room and the number of sound paths. Accordingly, the spatial air temperature in each voxel can be determined using a suitable tomographic algorithm. Recent studies indicate that despite the great potential of this technique to detect room climate, few experiments have been conducted. This thesis aims to develop the ATOM technique for indoor climatic applications while coupling the analysis methods of tomography and room acoustics. The method developed in this thesis uses high-energy early reflections in addition to the direct paths between transducers for travel time estimation. In this way, reflections can provide multiple sound paths that allow the room coverage to be maintained even when a few or even only one transmitter and receiver are used. In the development of the ATOM measurement system, several approaches have been employed, including the development of numerical methods and simulations and conducting experimental measurements, each of which has contributed to the improvement of the system's accuracy. In order to effectively separate the early reflections and ensure adequate coverage of the room with sound paths, a numerical method was developed based on the optimization of the coordinates of the sound transducers in the test room. The validation of the optimal positioning method shows that the reconstructed temperatures were significantly improved by placing the transducers at the optimal coordinates derived from the developed numerical method. The other numerical method developed is related to the selection of the travel times of the early reflections. Accordingly, the detection of the travel times has been improved by adjusting the lengths of the multiple analysis time-windows according to the individual travel times in the reflectogram of the room impulse response. This can reduce the probability of trapping faulty travel times in the analysis time-windows. The simulation model used in this thesis is based on the image source model (ISM) method for simulating the theoretical travel times of early reflection sound paths. The simulation model was developed to simulate the theoretical travel times up to third-order reflections. The empirical measurements were carried out in the climate lab of the Chair of Building Physics under different boundary conditions, i.e., combinations of different room air temperatures under both steady-state and transient conditions, and different measurement setups. With the measurements under controllable conditions in the climate lab, the validity of the developed numerical methods was confirmed. In this thesis, the performance of the ATOM measurement system was evaluated using two measurement setups. The setup for the initial investigations consists of an omnidirectional receiver and a near omnidirectional sound source, keeping the number of transducers as few as possible. This has led to accurately identify the sources of error that could occur in each part of the measuring system. The second measurement setup consists of two directional sound sources and one omnidirectional receiver. This arrangement of transducers allowed a higher number of well-detected travel times for tomography reconstruction, a better travel time estimation due to the directivity of the sound source, and better space utilization. Furthermore, this new measurement setup was tested to determine an optimal selection of the excitation signal. The results showed that for the utilized setup, a linear chirp signal with a frequency range of 200 - 4000 Hz and a signal duration of t = 1 s represents an optimal selection with respect to the reliability of the measured travel times and higher signal-to-noise ratio (SNR). To evaluate the performance of the measuring setups, the ATOM temperatures were always compared with the temperatures of high-resolution NTC thermistors with an accuracy of ±0.2 K. The entire measurement program, including acoustic measurements, simulation, signal processing, and visualization of measurement results are performed in MATLAB software. In addition, to reduce the uncertainty of the positioning of the transducers, the acoustic centre of the loudspeaker was determined experimentally for three types of excitation signals, namely MLS (maximum length sequence) signals with different lengths and duration, linear and logarithmic chirp signals with different defined frequency ranges. For this purpose, the climate lab was converted into a fully anechoic chamber by attaching absorption panels to the entire surfaces of the room. The measurement results indicated that the measurement of the acoustic centre of the sound source significantly reduces the displacement error of the transducer position. Moreover, to measure the air temperature in an occupied room, an algorithm was developed that can convert distorted signals into pure reference signals using an adaptive filter. The measurement results confirm the validity of the approach for a temperature interval of 4 K inside the climate lab. Accordingly, the accuracy of the reconstructed temperatures indicated that ATOM is very suitable for measuring the air temperature distribution in rooms. T3 - Schriftenreihe der Professur Bauphysik - 8 KW - Bauphysik KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230414-49567 SN - 978-3-00-075344-2 (print) ER - TY - JOUR A1 - Dokhanchi, Najmeh Sadat A1 - Arnold, Jörg A1 - Vogel, Albert A1 - Völker, Conrad T1 - Measurement of indoor air temperature distribution using acoustic travel-time tomography: Optimization of transducers location and sound-ray coverage of the room JF - Measurement N2 - Acoustic travel-time TOMography (ATOM) allows the measurement and reconstruction of air temperature distributions. Due to limiting factors, such as the challenge of travel-time estimation of the early reflections in the room impulse response, which heavily depends on the position of transducers inside the measurement area, ATOM is applied mainly outdoors. To apply ATOM in buildings, this paper presents a numerical solution to optimize the positions of transducers. This optimization avoids reflection overlaps, leading to distinguishable travel-times in the impulse response reflectogram. To increase the accuracy of the measured temperature within tomographic voxels, an additional function is employed to the proposed numerical method to minimize the number of sound-path-free voxels, ensuring the best sound-ray coverage of the room. Subsequently, an experimental set-up has been performed to verify the proposed numerical method. The results indicate the positive impact of the optimal positions of transducers on the distribution of ATOM-temperatures. KW - Bauphysik KW - Bauklimatik KW - Akustische Laufzeit-Tomographie Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220524-46473 UR - https://www.sciencedirect.com/science/article/abs/pii/S0263224120304723?via%3Dihub VL - 2020 IS - Volume 164, article 107934 PB - Elsevier CY - Amsterdam ER - TY - THES A1 - Schuster, Siegbert A1 - Schuster, Karl-Heinz T1 - Hygrothermische Gebäudesimulation – Experimentelle Bestimmung der Randparameter und Sorptionseigenschaften von historischen Räumen N2 - Forscher prognostizieren in den kommenden Jahren eine Klimaerwärmung bis zu 6 ° C. Aus diesem Grund wurde das EU – Forschungsprojekt „ Climate for Culture“ ins Leben gerufen, um Auswirkungen dieses Klimawandels auf denkmalgeschützte, kulturhistorische Gebäude zu untersuchen. Ziel ist es, entsprechende Schutzmaßnahmen in konservatorischer Hinsicht zu erarbeiten. Aufgrund des Zusammenhanges zwischen Temperatur und Luftfeuchte führt diese Klimaerwärmung auch zu einer Änderung des Feuchtehaushaltes im Außenbereich und, bedingt durch einen immer vorhandenen Luftwechsel, schließlich auch im Innenbereich von Gebäuden. Die Fähigkeit eines Gebäudes, durch seine Beschaffenheit auf Feuchteeinflüsse zu reagieren, wird maßgeblich bestimmt durch seine Möglichkeit, in der Gebäudehülle und der vorhandenen Einrichtung anfallende Feuchte zwischenzuspeichern und diese zeitversetzt wieder an die Umgebung abzugeben. Diese Fähigkeit sorptiver Flächen zur Feuchtepufferung konnte bislang nur mit erheblichem Aufwand ermittelt werden. In der vorliegenden Arbeit wird versucht, durch einfachere Methoden mittels hygrothermischer Simulation einen „Zweizahlwert“ zu erhalten, mit dem sich diese Raumkompetenz schnell und nachvollziehbar darstellen lässt. KW - Feuchtepufferung Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20131219-20936 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - GEN A1 - Müller, Naira A1 - Hennig, Christoph A1 - Aubel, Mario A1 - Hesse, Tobias A1 - Schneider, Sascha T1 - FlipLife als Mitarbeiterrekrutierungsquelle N2 - Ausgehend von der Aufgabenstellung umreißt diese Arbeit die Besonderheiten der Mitarbeiterrekrutierung und deren Anwendung im Internet, im speziellen bei Social-Games, gemessen an dem Spiel FlipLife. KW - Fliplife Mitarbeiterrekrutierung Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20120229-15727 ER - TY - THES A1 - Jahn, Rosa T1 - Evaluation von Nutzerbedürfnissen in Wohngebäuden unter Berücksichtigung hygrothermischer Messdaten N2 - Evaluation von Nutzerbedürfnissen in Wohngebäuden unter Berücksichtigung hygrothermischer Messdaten KW - Raumklima KW - Bauphysik KW - Umfrage Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20130320-18758 N1 - Der Volltext-Zugang wurde im Zusammenhang mit der Klärung urheberrechtlicher Fragen mit sofortiger Wirkung gesperrt. ER - TY - THES A1 - Müller, Naira T1 - Erweiterung von Fliplife mit bauphysikalischen Inhalten N2 - In dieser Arbeit wurde ein Konzept erstellt, das Fliplife um einen bauphysikalischen Karriereweg erweitert. In das Spiel wurden beispielhaft bauphysikalische Inhalte sowie spielkonzept-kompatible und wissensvermittelnde Spielmechaniken implementiert. KW - Social Game KW - Bauphysik KW - Fliplife KW - Lernspiele KW - Digital Games Based Learning Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20120704-16763 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Hilbel, Rebecca A1 - Völker, Conrad T1 - ENVI-met validation data accompanied with simulation data of the impact of facade greening on the urban microclimate JF - Data in Brief N2 - This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model. The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1]. KW - Messung KW - Measurements KW - Simulations KW - ENVI-met KW - Living wall KW - Green facade KW - Simulation KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220511-46455 UR - https://www.sciencedirect.com/science/article/pii/S2352340922004048#! VL - 2022 IS - Volume 42, article 108200 SP - 1 EP - 13 PB - Elsevier CY - Amsterdam ER - TY - THES A1 - Held, Janina T1 - Entwurf eines Spieler-Modells für eine erweiterbare Spielplattform zur Ausbildung in der Bauphysik N2 - Im Projekt Intelligentes Lernen beschäftigen sich die Professuren Content Management und Web-Technologien, Systeme der Virtuellen Realität und Bauphysik der Bauhaus- Universität Weimar mit der Entwicklung innovativer Informationstechnologien für eLearning- Umgebungen. In den Teilbereichen Retrieval, Extraktion und Visualisierung großer Dokumentkollektionen, sowie simulations- und planbasierter Wissensvermittlung werden Algorithmen und Werkzeuge erforscht, um eLearning-Systeme leistungsfähiger zu machen und um somit den Lernerfolg zu optimieren. Ziel des Projekts, auf dem Gebiet des simulationsbasierten Wissenstransfers, ist die Entwicklung eines Multiplayer Online Games (MOG) zur Ausbildungsunterstützung in der Bauphysik. Im Rahmen der vorliegenden Bachelorarbeit wird für diese digitale Lernsoftware ein Spieler- Modell zur Verwaltung der spielerspezifischen Daten entworfen und in das bestehende Framework integriert. Der Schwerpunkt der Arbeit liegt in der Organisation der erlernten Fähigkeiten des Spielers und in der an den Wissensstand angepassten Auswahl geeigneter Spielaufgaben. Für die Anwendung im eLearning-Bereich ist die Erweiterbarkeit des Modells um neue Lernkomplexe eine wesentliche Anforderung. KW - Skill KW - Skillsystem KW - Skillmanager KW - Missionsmanager KW - Spielermodell Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20120117-15249 ER - TY - THES A1 - Kühnert, Christin T1 - Entwicklung von Spielmechaniken für ein bauphysikalisches Social Game N2 - Eine der jüngsten Entwicklungen in der Games Branche sind sogenannte Social Games. Hierbei handelt es sich um digitale Spiele, die innerhalb von sozialen Netzwerken, wie z.B. Facebook und Myspace, gespielt werden. Studien zeigen, dass kommerzielle digitale Spiele mehr als nur ein Zeitvertreib sind. Sie fördern sowohl kognitive, als auch affektive und psychomotorische Kompetenzen. Aus diesem Grund werden seit Jahrzehnten digitale Spiele in der Pädagogik eingesetzt, um ihre Motivationskraft zu nutzen, um Lerneffekte zu erzielen. Ziel dieser Arbeit ist es Spielmechaniken für ein bauphysikalisches Social Game zu entwickeln. Ausgehend von der Identifikation von Spielmechaniken, basierend auf einer Analyse der Funktionsweisen existierender populärer Social Games, und einem grundlegenden pädagogischen Verständnis bezüglich Digital Game Based Learning (DGBL), werden Spielmechaniken entwickelt, mit deren Hilfe bauphysikalische Fachkompetenzen vermittelt werden können. KW - Computerunterstütztes Lernen KW - Lernspiel KW - Digital Game Based Learning Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20120117-15227 ER - TY - JOUR A1 - Pollack, Moritz A1 - Lück, Andrea A1 - Wolf, Mario A1 - Kraft, Eckhard A1 - Völker, Conrad T1 - Energy and Business Synergy: Leveraging Biogenic Resources from Agriculture, Waste, and Wastewater in German Rural Areas JF - Sustainability N2 - The imperative to transform current energy provisions is widely acknowledged. However, scant attention has hitherto been directed toward rural municipalities and their innate resources, notably biogenic resources. In this paper, a methodological framework is developed to interconnect resources from waste, wastewater, and agricultural domains for energy utilization. This entails cataloging existing resources, delineating their potential via quantitative assessments utilizing diverse technologies, and encapsulating them in a conceptual model. The formulated models underwent iterative evaluation with engagement from diverse stakeholders. Consequently, 3 main concepts, complemented by 72 sub-concepts, were delineated, all fostering positive contributions to climate protection and providing heat supply in the rural study area. The outcomes’ replicability is underscored by the study area’s generic structure and the employed methodology. Through these inquiries, a framework for the requisite energy transition, with a pronounced emphasis on the coupling of waste, wastewater, and agriculture sectors in rural environments, is robustly analyzed. KW - Energiewende KW - Energieplanung KW - Abfallwirtschaft KW - organischer Abfall KW - Biomasse KW - Regionalentwicklung KW - biogene Abfallstoffe KW - Abwassermanagement KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20231222-65172 UR - https://www.mdpi.com/2071-1050/15/24/16573 VL - 2023 IS - volume 15, issue 24, article 16573 SP - 1 EP - 25 PB - MDPI CY - Basel ER - TY - CHAP A1 - Kiesel, Gerd A1 - Engels, Merit A1 - Völker, Conrad ED - Kornadt, Oliver ED - Carrigan, Svenja ED - Hofmann, Markus ED - Völker, Conrad T1 - Energetische Transformation im ländlichen Raum – Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells T2 - Schriftenreihe des Fachgebiets Bauphysik/Energetische Gebäudeoptimierung N2 - Kleine Kommunen im ländlichen Raum sind aufgrund ihrer oft eingeschränkten personellen und finanziellen Kapazitäten bisher eher sporadisch in den Themenfeldern Energieeffizienz und Erneuerbare Energien aktiv. Immer wieder stellt sich daher Frage, wie die Klimaschutzstrategien des Bundes und der Länder dort mit dem verfügbaren Personal kostengünstig realisierbar sind. Vor diesem Hintergrund wird ein Werkzeug entwickelt, mit dessen Hilfe der aktive Einstieg in diese Thematik mit geringen Aufwand und überwiegend barrierefrei möglich ist. Der Aufbau eines prozessorientierten Entwicklungs- und Moderationsmodells zur Erprobung und Umsetzung bezahlbarer Handlungsoptionen für Energieeinsparungen und effizienten Energieeinsatz im überwiegend ländlichen geprägten Raum ist der Schwerpunkt der Softwarelösung. Kommunen werden mit deren Hilfe in die Lage versetzt, in die notwendigen Prozesse der Energie- und Wärmewende einzusteigen. Dabei soll der modulare Aufbau die regulären Schritte notwendiger (integrierter) Planungsprozesse nicht vollständig ersetzen. Vielmehr können innerhalb der Online-Anwendung - überwiegend automatisiert - konkrete Maßnahmenvorschläge erstellt werden, die ein solides Fundament der künftigen energetischen Entwicklung der Kommunen darstellen. Für eine gezielte Validierung der Ergebnisse und der Ableitung potentieller Maßnahmen werden für die Erprobung Modellkommunen in Thüringen, Bayern und Hessen als Reallabore einbezogen. Das Tool steht bisher zunächst nur den beteiligten Modellkommunen zur Verfügung. Die entwickelte Softwarelösung soll künftig Schritt für Schritt allen interessierten Kommunen mit diversen Hilfsmitteln und einer Vielzahl anderer praktischer Bestandteile zur Verfügung gestellt werden. KW - Modellierung KW - Kommune KW - Energiewende KW - Transformation KW - ländlicher Raum Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220617-46566 SN - 978-3-95974-176-7 SN - 2363-8206 PB - Eigenverlag Technische Universität Kaiserslautern CY - Kaiserslautern ER -