TY - JOUR A1 - Dokhanchi, Najmeh Sadat A1 - Arnold, Jörg A1 - Vogel, Albert A1 - Völker, Conrad T1 - Measurement of indoor air temperature distribution using acoustic travel-time tomography: Optimization of transducers location and sound-ray coverage of the room JF - Measurement N2 - Acoustic travel-time TOMography (ATOM) allows the measurement and reconstruction of air temperature distributions. Due to limiting factors, such as the challenge of travel-time estimation of the early reflections in the room impulse response, which heavily depends on the position of transducers inside the measurement area, ATOM is applied mainly outdoors. To apply ATOM in buildings, this paper presents a numerical solution to optimize the positions of transducers. This optimization avoids reflection overlaps, leading to distinguishable travel-times in the impulse response reflectogram. To increase the accuracy of the measured temperature within tomographic voxels, an additional function is employed to the proposed numerical method to minimize the number of sound-path-free voxels, ensuring the best sound-ray coverage of the room. Subsequently, an experimental set-up has been performed to verify the proposed numerical method. The results indicate the positive impact of the optimal positions of transducers on the distribution of ATOM-temperatures. KW - Bauphysik KW - Bauklimatik KW - Akustische Laufzeit-Tomographie Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220524-46473 UR - https://www.sciencedirect.com/science/article/abs/pii/S0263224120304723?via%3Dihub VL - 2020 IS - Volume 164, article 107934 PB - Elsevier CY - Amsterdam ER - TY - INPR A1 - Vogel, Albert A1 - Völker, Conrad A1 - Bode, Matthias A1 - Marx, Steffen T1 - Messung und Simulation der Erwärmung von ermüdungsbeanspruchten Betonprobekörpern T2 - Bauphysik N2 - Im vorliegenden Beitrag werden Messungen und Berechnungen vorgestellt, die die Temperaturentwicklung in Betonzylindern aufgrund zyklischer Beanspruchung genau beschreiben. Die Messungen wurden in einem Versuchsstand, die Berechnungen im FEM-Programm ANSYS durchgeführt. Mit Hilfe der Temperaturmessungen konnten die Simulationen für die Temperaturentwicklung der Betonzylinder mit der verwendeten Betonrezeptur validiert werden. Die Untersuchungen lassen den Schluss zu, dass bei zyklischer Probekörperbelastung und der einhergehenden Probekörperdehnung Energie dissipiert wird und diese maßgeblich für die Erwärmung der Probe verantwortlich ist. N2 - This paper presents measurements and simulations that describe the temperature development in concrete cylinders due to cyclic loading. The measurements were carried out in a test stand, the simulations in the FEM program ANSYS. The simulations of the temperature development in the concrete cylinders with the used concrete recipe were validated using the temperature measurements. The investigations lead to the conclusion that energy is dissipated during cyclic test specimen loading and the accompanying test specimen elongation and that this is mainly responsible for the heating of the specimen. KW - zyklische Beanspruchung KW - Ermüdung KW - Dissipation KW - zyklische Beanspruchung KW - Ermüdung KW - Dissipation KW - cyclic load KW - fatigue Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200425-41471 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.201900031 N1 - This is the pre-peer reviewed version of the following article: hhttps://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.201900031, which has been published in final form at https://doi.org/10.1002/bapi.201900031. VL - 2020 IS - Volume 42, Issue 2 SP - 86 EP - 93 PB - John Wiley and Sons ER - TY - INPR A1 - Vogel, Albert A1 - Benz, Alexander A1 - Völker, Conrad T1 - Untersuchung des Wärmeübergangs von zyklisch beanspruchten Betonzylindern N2 - Wiederkehrende Belastungen, wie sie beispielsweise an Brücken oder Windenergieanlagen auftreten, können innerhalb der Nutzungsdauer solcher Bauwerke bis zu 1.000.000.000 Lastwechsel erreichen. Um das dadurch eintretende Ermüdungsverhalten von Beton zu untersuchen, werden diese zyklischen Beanspruchungen in mechanischen Versuchen mit Prüfzylindern nachgestellt. Damit Versuche mit solch hohen Lastwechselzahlen in akzeptablen Zeitdauern durchgeführt werden können, wird die Belastungsfrequenz erhöht. Als Folge dieser erhöhten Belas-tungsfrequenz erwärmen sich allerdings die Betonprobekörper, was zu einem früheren, unrealistischen Versagenszeitpunkt führen kann, weshalb die Erwärmung begrenzt werden muss. Um die Wärmefreisetzung in der Probe zu untersuchen, wurden Versuche und Simulationen durchgeführt. Im Beitrag wird die analytische und messtechnische Analyse des Wärmeübergangs an erwärmten Betonzylindern vorgestellt. Resultierend daraus wird eine Möglichkeit zur Reduktion der Erwärmung an zyklisch beanspruchten Betonzylindern vorgestellt. N2 - Periodic load cycles, such as those that occur on bridges or wind turbines, are of great importance for dynamic long-term considerations of concrete. Within the life span of such structures, up to 1,000,000,000 load changes can be expected. To determine the fatigue strength, the resistance to periodic loads can be determined in a short time in laboratory tests by increasing the load frequency. As a result of this increased load frequency, however, the concrete test specimens heat up, which can lead to an earlier, unrealistic time of failure, which is why the heating must be limited. Therefore, tests and simulations were carried out to investigate the heat release in the sample. In this article, the analytical analysis and measurements of the heat release of heated concrete cylinders are presented. As a conclusion, a possibility of reducing the temperature of dynamically stressed concrete cylinders is introduced. KW - Zyklische Beanspruchung KW - Wärmeübergang KW - Wärmeübergangskoeffizient KW - Dissipation KW - Wärmeübergangskoeffizient an Zylinder KW - heat transfer coefficient for cylinders KW - cyclic load Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200619-41813 N1 - This is the pre-peer reviewed version of the following article: https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.202000004, which has been published in final form at https://doi.org/10.1002/bapi.202000004 VL - 2020 IS - Volume 42, Issue 3 SP - 131 EP - 138 PB - John Wiley and Sons ER -