TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Hilbel, Rebecca A1 - Völker, Conrad T1 - ENVI-met validation data accompanied with simulation data of the impact of facade greening on the urban microclimate JF - Data in Brief N2 - This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model. The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1]. KW - Messung KW - Measurements KW - Simulations KW - ENVI-met KW - Living wall KW - Green facade KW - Simulation KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220511-46455 UR - https://www.sciencedirect.com/science/article/pii/S2352340922004048#! VL - 2022 IS - Volume 42, article 108200 SP - 1 EP - 13 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Voelker, Conrad T1 - The effect of a living wall system designated for greywater treatment on the hygrothermal performance of the facade JF - Energy and Buildings N2 - Besides their multiple known benefits regarding urban microclimate, living walls can be used as decentralized stand-alone systems to treat greywater locally at the buildings. While this offers numerous environmental advantages, it can have a considerable impact on the hygrothermal performance of the facade as such systems involve bringing large quantities of water onto the facade. As it is difficult to represent complex entities such as plants in the typical simulation tools used for heat and moisture transport, this study suggests a new approach to tackle this challenge by coupling two tools: ENVI-Met and Delphin. ENVI-Met was used to simulate the impact of the plants to determine the local environmental parameters at the living wall. Delphin, on the other hand, was used to conduct the hygrothermal simulations using the local parameters calculated by ENVI-Met. Four wall constructions were investigated in this study: an uninsulated brick wall, a precast concrete plate, a sandy limestone wall, and a double-shell wall. The results showed that the living wall improved the U-value, the exterior surface temperature, and the heat flux through the wall. Moreover, the living wall did not increase the risk of moisture in the wall during winter and eliminated the risk of condensation. KW - Feuchteleitung KW - Diffusionswärme KW - Heat transport KW - Moisture transport KW - Living wall KW - Delphin KW - ENVI-Met Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20240116-65299 UR - https://www.sciencedirect.com/science/article/pii/S0378778821009956 VL - 2022 IS - volume 255, article 111711 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Schälte, Gereon A1 - Schneeweiß, Mario A1 - Becher, Lia A1 - Pollack, Moritz A1 - Gena, Amayu Wakoya A1 - Schweiker, Marcel A1 - Hartmann, Maria A1 - Voelker, Conrad A1 - Rossaint, Rolf A1 - Irrgang, Matthias T1 - The Spread of Exhaled Air and Aerosols during Physical Exercise JF - Journal of Clinical Medicine N2 - Physical exercise demonstrates a special case of aerosol emission due to its associated elevated breathing rate. This can lead to a faster spread of airborne viruses and respiratory diseases. Therefore, this study investigates cross-infection risk during training. Twelve human subjects exercised on a cycle ergometer under three mask scenarios: no mask, surgical mask, and FFP2 mask. The emitted aerosols were measured in a grey room with a measurement setup equipped with an optical particle sensor. The spread of expired air was qualitatively and quantitatively assessed using schlieren imaging. Moreover, user satisfaction surveys were conducted to evaluate the comfort of wearing face masks during training. The results indicated that both surgical and FFP2 masks significantly reduced particles emission with a reduction efficiency of 87.1% and 91.3% of all particle sizes, respectively. However, compared to surgical masks, FFP2 masks provided a nearly tenfold greater reduction of the particle size range with long residence time in the air (0.3–0.5 μm). Furthermore, the investigated masks reduced exhalation spreading distances to less than 0.15 m and 0.1 m in the case of the surgical mask and FFP2 mask, respectively. User satisfaction solely differed with respect to perceived dyspnea between no mask and FFP2 mask conditions. KW - Sport KW - Training KW - Fahrradergometer KW - sport KW - training KW - cycle ergometer KW - schlieren imaging KW - particles concentration KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230208-49262 UR - https://www.mdpi.com/2077-0383/12/4/1300 VL - 2023 IS - Volume 12, issue 4, article 1300 PB - Basel CY - MDPI ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance assessment of a ductless personalized ventilation system using a validated CFD model JF - Journal of Building Performance Simulation N2 - The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model. KW - Ventilation KW - Validierung KW - Strömungsmechanik KW - Raumklima KW - personalized ventilation KW - validation KW - computational fluid dynamics KW - thermal comfort KW - indoor air quality Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20190218-38500 UR - https://www.tandfonline.com/doi/full/10.1080/19401493.2018.1431806 N1 - Copyright 2018 Taylor & Francis Group and the International Building Performance Simulation Association (IBPSA). This article may be downloaded for personal use only. Any other use requires prior permission of the authors and Taylor & Francis Group. This is an Accepted Manuscript of an article published by Taylor & Francis in the Journal of Building Performance Simulation 11 (6), 689–704 (2018) and may be found at https://doi.org/10.1080/19401493.2018.1431806 VL - 2018 IS - 11, Heft 6 SP - 689 EP - 704 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Qualitative evaluation of the flow supplied by personalized ventilation using schlieren imaging and thermography JF - Building and Environment N2 - Personalized ventilation (PV) is a mean of delivering conditioned outdoor air into the breathing zone of the occupants. This study aims to qualitatively investigate the personalized flows using two methods of visualization: (1) schlieren imaging using a large schlieren mirror and (2) thermography using an infrared camera. While the schlieren imaging was used to render the velocity and mass transport of the supplied flow, thermography was implemented to visualize the air temperature distribution induced by the PV. Both studies were conducted using a thermal manikin to simulate an occupant facing a PV outlet. As a reference, the flow supplied by an axial fan and a cased axial fan was visualized with the schlieren system as well and compared to the flow supplied by PV. Schlieren visualization results indicate that the steady, low-turbulence flow supplied by PV was able to penetrate the thermal convective boundary layer encasing the manikin's body, providing clean air for inhalation. Contrarily, the axial fan diffused the supplied air over a large target area with high turbulence intensity; it only disturbed the convective boundary layer rather than destroying it. The cased fan supplied a flow with a reduced target area which allowed supplying more air into the breathing zone compared to the fan. The results of thermography visualization showed that the supplied cool air from PV penetrated the corona-shaped thermal boundary layer. Furthermore, the supplied air cooled the surface temperature of the face, which indicates the large impact of PV on local thermal sensation and comfort. KW - Bildverarbeitung KW - Photothermische Methode KW - Visualisierung KW - Belüftung KW - Lüftungsanlage KW - Schlieren imaging KW - Thermography KW - Visualization KW - Personalized ventilation KW - Axial fan Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211008-45117 UR - https://www.sciencedirect.com/science/article/abs/pii/S0360132319306602?via%3Dihub N1 - This is the accepted manuscript of the article published by Elsevier in Building and Environment 167 (2020) 106450, which can be found at https://doi.org/10.1016/j.buildenv.2019.106450. VL - 2020 IS - Volume 167, article 106450 PB - Elsevier CY - New York ER - TY - CHAP A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Measuring and visualizing the flow supplied by personalized ventilation T2 - Proceedings Book Roomvent 2020 N2 - This study investigates the flow supplied by personalized ventilation (PV) by means of anemometer measurements and schlieren visualization. The study was conducted using a thermal manikin to simulate a seated occupant facing a PV outlet. Air velocity was measured at multiple points in the flow field; the collected velocity values were used to calculate the turbulence intensity. Results indicated that PV was supplying air with low turbulence intensity that was able to penetrate the convective boundary layer of the manikin to supply clean air for inhalation. The convective boundary layer, however, obstructed the supplied flow and reduced its velocity by a total of 0.26 m/s. The PV flow preserved its value until about 10 cm from the face where velocity started to drop. Further investigations were conducted to test a PV diffuser with a relatively large outlet diameter (18 cm). This diffuser was developed using 3d-modelling and 3d-printing. The diffuser successfully distributed the flow over the larger outlet area. However, the supplied velocity and turbulence fields were not uniform across the section. KW - Belüftung KW - Luftqualität KW - Personalized ventilation KW - Schlieren imaging KW - Air quality KW - Thermal manikin Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46573 CY - Turin, Italy ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Der Kühlungseffekt der personalisierten Lüftung T1 - The cooling effect of personalized ventilation systems JF - Bauphysik N2 - Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden. N2 - Personalized ventilation (PV) can improve thermal comfort and inhaled air quality by supplying air to each workstation separately. This study investigates the impact of PV on the thermal state of the users under summer boundary conditions. Two approaches to evaluating the cooling effect of PV were investigated, based on equivalent temperature and based on thermal sensation. Both approaches implemented measured and simulated values of the cooling effect of PV. Before conducting the simulations, the numerical model was first validated against measured data collected in a climate chamber equipped with a thermal manikin. Results indicated that the thermal sensation approach can be more suitable for evaluating the cooling effect of PV due to the complex physiological factors it considers. KW - Lüftung KW - Strömung KW - Raumklima KW - Temperatur KW - personalized ventilation KW - computational fluid dynamics KW - Simulation KW - personalisierte Lüftung KW - äquivalente Temperatur KW - thermisches Empfinden Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20201020-42723 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.202000018 N1 - © 2020 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 42 (2020), Heft 5, 218-225, DOI: 10.1002/bapi.202000018 VL - 2020 IS - volume 42, issue 5 SP - 218 EP - 225 PB - Ernst & Sohn bei John Wiley & Sons CY - Hoboken ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations JF - Indoor Air N2 - The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant. KW - Behaglichkeit KW - Raumklima KW - Strömungsmechanik KW - Fluid KW - computational fluid dynamics KW - desk fan KW - ductless personalized ventilation KW - IAQ KW - thermal comfort Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200422-41407 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12672 VL - 2020 PB - John Wiley & Sons Ltd ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation? JF - Indoor Air N2 - This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off. KW - Strömungsmechanik KW - Kontamination KW - Belüftung KW - Luftqualität KW - computational fluid dynamics KW - cross-contamination KW - ductless personalized ventilation KW - indoor air quality KW - tracer gas Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200805-42072 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12720 VL - 2020 PB - John Wiley & Sons Ltd ER - TY - THES A1 - Arnold, Jörg T1 - Raumakustische Rekonstruktion der Schlosskapelle des Weimarer Residenzschlosses im Zustand von 1658 - 1774 N2 - In dieser Arbeit wird eine umfassende Untersuchung der raumakustischen Qualität der Schlosskapelle des Weimarer Residenzschlosses für den Zustand, wie sie zwischen 1658 und 1774 existierte, durchgeführt. Die Schlosskapelle als sakraler Raum innerhalb der Schlossanlage diente der Ausübung religiöser Handlungen und war fester Bestandteil des kulturellen Lebens am Weimarer Hof. Eine wesentliche Bedeutung erlangte sie in diesem Zusammenhang als musikalische Wirkungsstätte Johann Sebastian Bachs. Mit ihrer akustischen Qualität hatte sie einen erheblichen Einfluss auf sein musikalisches Schaffen. Die Untersuchung der raumakustischen Situation stellt damit eine notwendige Grundlage für eine musikwissenschaftliche Einordnung der Schlosskapelle als Aufführungsstätte geistlicher Kompositionen dar. Der raumakustische Zustand der Weimarer Schlosskapelle ist eng mit der baulichen Entwicklung der gesamten Schlossanlage verbunden, die infolge äußerer Einflüsse einem steten Wandel unterlag. Die Umgestaltung der Schlosskapelle zu Beginn des 17. Jahrhunderts erfolgte nach barocken Raumvorstellungen. Einen wesentlichen Einfluss auf die Gestaltung des Innenraumes übte zudem die reformierte Kirche mit ihren liturgischen Anforderungen aus. Die historische Entwicklung der architektonischen Stilepoche sowie der protestantischen Kirche wird in Bezug zu dem akustischen Erscheinungsbild der Schlosskapelle näher untersucht. Ausgehend von der architektonischen Rekonstruktion wird die Raumstruktur der historischen Schlosskapelle in ein Computermodell übertragen, mit dem die Berechnung akustischer Bewertungskriterien möglich ist. Eine ausgiebige Recherche nach verwendeten Materialien und der Ausbildung baulicher Konstruktionen ist dabei die Grundvoraussetzung für aussagekräftige Simulationsergebnisse. Die Wahl der Materialparameter sowie der Einfluss der geometrischen Besonderheiten der Weimarer Schlosskapelle auf die simulierten Schallfeldparameter werden durch die Untersuchung eines Referenzobjektes verifiziert. Dafür werden die akustischen Bewertungskriterien mit einer raumakustischen Messung ermittelt und mit Simulationsergebnissen verglichen. Ein besonderes Interesse bei der Simulation der Schlosskapelle gilt der Nachhallzeit als Charakteristikum der Halligkeit, die in sakralen Gebäuden die auffälligste akustische Raumeigenschaft darstellt. Mit der rekonstruierten Nachhallzeit wird die Schlosskapelle mit barocken Kirchen verglichen und bezüglich ihrer Lage im baustiltypischen Bereich beurteilt. Der Direktschall und die im zeitig folgenden Reflexionen sind bei der raumakustischen Simulation maßgeblicher Gegenstand der Betrachtung. Während der Nachhall das Verschmelzen einzelner Töne zu einem Gesamtklang fördert, ist der Direktschall für die Deutlichkeit von Sprache und der klanglichen Durchsichtigkeit von musikalischen Strukturen verantwortlich. Der Einfluss des Direktschalls wird mit speziellen Energiekriterien beurteilt, mit denen gezielte Aussagen über die akustische Qualität einzelner Platzbereiche möglich sind. Die unterschiedlichen akustischen Anforderungen an die Schlosskapelle bei der jeweiligen Nutzung des Raumes werden mit den Energiekriterien differenziert untersucht und bewertet. KW - Raumakustik KW - Rekonstruktion KW - Computersimulation KW - Schall KW - Kirchenbau KW - Raumakustische Rekonstruktion KW - Weimar / Schloss Wilhelmsburg / Schlosskapelle Himmelsburg KW - Akustik im Barock KW - Musik im Barock KW - room acoustics KW - computer simulation KW - historic church KW - historic palace Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-6424 ER - TY - JOUR A1 - Becher, Lia A1 - Gena, Amayu Wakoya A1 - Alsaad, Hayder A1 - Richter, Bernhard A1 - Spahn, Claudia A1 - Völker, Conrad T1 - The spread of breathing air from wind instruments and singers using schlieren techniques JF - Indoor Air N2 - The spread of breathing air when playing wind instruments and singing was investigated and visualized using two methods: (1) schlieren imaging with a schlieren mirror and (2) background-oriented schlieren (BOS). These methods visualize airflow by visualizing density gradients in transparent media. The playing of professional woodwind and brass instrument players, as well as professional classical trained singers were investigated to estimate the spread distances of the breathing air. For a better comparison and consistent measurement series, a single high note, a single low note, and an extract of a musical piece were investigated. Additionally, anemometry was used to determine the velocity of the spreading breathing air and the extent to which it was quantifiable. The results showed that the ejected airflow from the examined instruments and singers did not exceed a spreading range of 1.2 m into the room. However, differences in the various instruments have to be considered to assess properly the spread of the breathing air. The findings discussed below help to estimate the risk of cross-infection for wind instrument players and singers and to develop efficacious safety precautions, which is essential during critical health periods such as the current COVID-19 pandemic. KW - Covid-19 KW - Pandemie KW - Blasinstrument KW - Gesang KW - Schlierenmethode KW - airborne infection KW - background-oriented schlieren KW - schlieren imaging Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220209-45817 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12869 VL - 2021 IS - volume 31, issue 6 SP - 1798 EP - 1814 PB - Wiley Blackwell CY - Oxford ER - TY - JOUR A1 - Becher, Lia A1 - Völker, Conrad A1 - Rodehorst, Volker A1 - Kuhne, Michael T1 - Background-oriented schlieren technique for two-dimensional visualization of convective indoor air flows JF - Optics and Lasers in Engineering N2 - This article focuses on further developments of the background-oriented schlieren (BOS) technique to visualize convective indoor air flow, which is usually defined by very small density gradients. Since the light rays deflect when passing through fluids with different densities, BOS can detect the resulting refractive index gradients as integration along a line of sight. In this paper, the BOS technique is used to yield a two-dimensional visualization of small density gradients. The novelty of the described method is the implementation of a highly sensitive BOS setup to visualize the ascending thermal plume from a heated thermal manikin with temperature differences of minimum 1 K. To guarantee steady boundary conditions, the thermal manikin was seated in a climate laboratory. For the experimental investigations, a high-resolution DLSR camera was used capturing a large field of view with sufficient detail accuracy. Several parameters such as various backgrounds, focal lengths, room air temperatures, and distances between the object of investigation, camera, and structured background were tested to find the most suitable parameters to visualize convective indoor air flow. Besides these measurements, this paper presents the analyzing method using cross-correlation algorithms and finally the results of visualizing the convective indoor air flow with BOS. The highly sensitive BOS setup presented in this article complements the commonly used invasive methods that highly influence weak air flows. KW - Raumklima KW - Raumluftströmungen KW - Flow visualization KW - Convective indoor air flow KW - Background-oriented schlieren KW - Human thermal plume KW - Cross-correlation Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220810-46972 N1 - This article is published by Elsevier in Optics and Lasers in Engineering 134 (2020) 106282 and may be found at https://doi.org/10.1016/j.optlaseng.2020.106282 Copyright © 2020 Elsevier Ltd. All rights reserved. This article may be downloaded for personal use only. Any other use requires prior permission of the authors and Elsevier Ltd. VL - 2020 IS - Volume 134, article 106282 ER - TY - JOUR A1 - Benz, Alexander A1 - Taraben, Jakob A1 - Lichtenheld, Thomas A1 - Morgenthal, Guido A1 - Völker, Conrad T1 - Thermisch-energetische Gebäudesimulation auf Basis eines Bauwerksinformationsmodells JF - Bauphysik N2 - Für eine Abschätzung des Heizwärmebedarfs von Gebäuden und Quartieren können thermisch-energetische Simulationen eingesetzt werden. Grundlage dieser Simulationen sind geometrische und physikalische Gebäudemodelle. Die Erstellung des geometrischen Modells erfolgt in der Regel auf Basis von Bauplänen oder Vor-Ort-Begehungen, was mit einem großen Recherche- und Modellierungsaufwand verbunden ist. Spätere bauliche Veränderungen des Gebäudes müssen häufig manuell in das Modell eingearbeitet werden, was den Arbeitsaufwand zusätzlich erhöht. Das physikalische Modell stellt die Menge an Parametern und Randbedingungen dar, welche durch Materialeigenschaften, Lage und Umgebungs-einflüsse gegeben sind. Die Verknüpfung beider Modelle wird innerhalb der entsprechenden Simulations-software realisiert und ist meist nicht in andere Softwareprodukte überführbar. Mithilfe des Building Information Modeling (BIM) können Simulationsdaten sowohl konsistent gespeichert als auch über Schnittstellen mit entsprechenden Anwendungen ausgetauscht werden. Hierfür wird eine Methode vorgestellt, die thermisch-energetische Simulationen auf Basis des standardisierten Übergabe-formats Industry Foundation Classes (IFC) inklusive anschließender Auswertungen ermöglicht. Dabei werden geometrische und physikalische Parameter direkt aus einem über den gesamten Lebenszyklus aktuellen Gebäudemodell extrahiert und an die Simulation übergeben. Dies beschleunigt den Simulations-prozess hinsichtlich der Gebäudemodellierung und nach späteren baulichen Veränderungen. Die erarbeite-te Methode beruht hierbei auf einfachen Modellierungskonventionen bei der Erstellung des Bauwerksinformationsmodells und stellt eine vollständige Übertragbarkeit der Eingangs- und Ausgangswerte sicher. Thermal building simulation based on BIM-models. Thermal energetic simulations are used for the estimation of the heating demand of buildings and districts. These simulations are based on building models containing geometrical and physical information. The creation of geometrical models is usually based on existing construction plans or in situ assessments which demand a comparatively big effort of investigation and modeling. Alterations, which are later applied to the structure, request manual changes of the related model, which increases the effort additionally. The physical model represents the total amount of parameters and boundary conditions that are influenced by material properties, location and environmental influences on the building. The link between both models is realized within the correspondent simulation soft-ware and is usually not transferable to other software products. By Applying Building Information Modeling (BIM) simulation data is stored consistently and an exchange to other software is enabled. Therefore, a method which allows a thermal energetic simulation based on the exchange format Industry Foundation Classes (IFC) including an evaluation is presented. All geometrical and physical information are extracted directly from the building model that is kept up-to-date during its life cycle and transferred to the simulation. This accelerates the simulation process regarding the geometrical modeling and adjustments after later changes of the building. The developed method is based on simple conventions for the creation of the building model and ensures a complete transfer of all simulation data. KW - Building Information Modeling KW - Energiebedarf KW - Gebäudehülle KW - Schnittstelle KW - Simulation KW - BIM KW - Gebäudesimulation KW - IFC-basierte Gebäudesimulation KW - thermische Gebäudehülle KW - building simulation Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181221-38354 N1 - Copyright 2018 Ernst & Sohn. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 40 (2), 2018 und kann unter folgendem Link abgerufen werden. https://www.ernst-und-sohn.de/app/artikelrecherche/artikel.php?lang=de&ID=38470&utm_source=eus&utm_medium=artikel-db&utm_campaign=Bp_2018_2 IS - 40, Heft 2 SP - 61 EP - 67 ER - TY - JOUR A1 - Benz, Alexander A1 - Taraben, Jakob A1 - Lichtenheld, Thomas A1 - Morgenthal, Guido A1 - Völker, Conrad T1 - Thermisch-energetische Gebäudesimulation auf Basis eines Bauwerksinformationsmodells JF - Bauphysik N2 - Für eine Abschätzung des Heizwärmebedarfs von Gebäuden und Quartieren können thermisch-energetische Simulationen eingesetzt werden. Grundlage dieser Simulationen sind geometrische und physikalische Gebäudemodelle. Die Erstellung des geometrischen Modells erfolgt in der Regel auf Basis von Bauplänen oder Vor-Ort-Begehungen, was mit einem großen Recherche- und Modellierungsaufwand verbunden ist. Spätere bauliche Veränderungen des Gebäudes müssen häufig manuell in das Modell eingearbeitet werden, was den Arbeitsaufwand zusätzlich erhöht. Das physikalische Modell stellt die Menge an Parametern und Randbedingungen dar, welche durch Materialeigenschaften, Lage und Umgebungs-einflüsse gegeben sind. Die Verknüpfung beider Modelle wird innerhalb der entsprechenden Simulations-software realisiert und ist meist nicht in andere Softwareprodukte überführbar. Mithilfe des Building Information Modeling (BIM) können Simulationsdaten sowohl konsistent gespeichert als auch über Schnittstellen mit entsprechenden Anwendungen ausgetauscht werden. Hierfür wird eine Methode vorgestellt, die thermisch-energetische Simulationen auf Basis des standardisierten Übergabe-formats Industry Foundation Classes (IFC) inklusive anschließender Auswertungen ermöglicht. Dabei werden geometrische und physikalische Parameter direkt aus einem über den gesamten Lebenszyklus aktuellen Gebäudemodell extrahiert und an die Simulation übergeben. Dies beschleunigt den Simulations-prozess hinsichtlich der Gebäudemodellierung und nach späteren baulichen Veränderungen. Die erarbeite-te Methode beruht hierbei auf einfachen Modellierungskonventionen bei der Erstellung des Bauwerksinformationsmodells und stellt eine vollständige Übertragbarkeit der Eingangs- und Ausgangswerte sicher. Thermal building simulation based on BIM-models. Thermal energetic simulations are used for the estimation of the heating demand of buildings and districts. These simulations are based on building models containing geometrical and physical information. The creation of geometrical models is usually based on existing construction plans or in situ assessments which demand a comparatively big effort of investigation and modeling. Alterations, which are later applied to the structure, request manual changes of the related model, which increases the effort additionally. The physical model represents the total amount of parameters and boundary conditions that are influenced by material properties, location and environmental influences on the building. The link between both models is realized within the correspondent simulation soft-ware and is usually not transferable to other software products. By Applying Building Information Modeling (BIM) simulation data is stored consistently and an exchange to other software is enabled. Therefore, a method which allows a thermal energetic simulation based on the exchange format Industry Foundation Classes (IFC) including an evaluation is presented. All geometrical and physical information are extracted directly from the building model that is kept up-to-date during its life cycle and transferred to the simulation. This accelerates the simulation process regarding the geometrical modeling and adjustments after later changes of the building. The developed method is based on simple conventions for the creation of the building model and ensures a complete transfer of all simulation data. KW - Gebäudehülle KW - Energiebedarf KW - Simulation KW - Schnittstelle KW - Building Information Modeling KW - Gebäudesimulation KW - BIM KW - IFC-basierte Gebäudesimulation KW - thermische Gebäudehülle KW - building simulation Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20181102-38190 UR - https://e-pub.uni-weimar.de/opus4/frontdoor/index/index/docId/3835 N1 - Copyright 2018 Ernst & Sohn. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 40 (2), 2018 und kann unter folgendem Link abgerufen werden. https://www.ernst-und-sohn.de/app/artikelrecherche/artikel.php?lang=de&ID=38470&utm_source=eus&utm_medium=artikel-db&utm_campaign=Bp_2018_2. IS - 40, Heft 2 SP - 61 EP - 67 ER - TY - INPR A1 - Bode, Matthias A1 - Marx, Steffen A1 - Vogel, Albert A1 - Völker, Conrad T1 - Dissipationsenergie bei Ermüdungsversuchen an Betonprobekörpern N2 - Aufgrund des visko-elastoplastischen Materialverhaltens von Beton wird Probekörpern und Bauteilen infolge zyklischer Beanspruchungen Energie zugeführt. Die entsprechenden Energiegrößen werden durch Hystereseflächen der Spannungs-Dehnungslinien beschrieben. In der Literatur finden sich dabei unterschiedliche Ansätze, wofür diese Energie verwendet wird. Erste Untersuchungen zeigen, dass zumindest ein Teil dieser dissipierten Energie in thermische Energie umgewandelt wird. Mithilfe der in diesem Beitrag beschriebenen Methodik lassen sich diese Energiegrößen für jeden Lastwechsel eines Ermüdungsversuches schnell und zuverlässig bestimmen. Anschließend wurden mit dem implementierten Algorithmus die dissipierten Energien von insgesamt 27 zyklischen Versuchen ausgewertet. Analog zu der Dehnungsentwicklung und der Steifigkeitsdegradation weisen auch die Verläufe der dissipierten Energie über die Lastwechselzahl einen dreiphasigen Verlauf auf. Die Auswertung zeigt außerdem eine Korrelation zwischen der Bruchlastwechselzahl und der dissipierten Energie. Auch der Zusammenhang zwischen Probekörpererwärmung und dissipierter Energie konnte bestätigt werden. KW - Ermüdung KW - Beton KW - Dissipationsenergie KW - Probekörpererwärmung Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211012-44938 UR - https://onlinelibrary.wiley.com/doi/10.1002/best.201900004 N1 - This is the pre-peer reviewed version of the following article: https://onlinelibrary.wiley.com/doi/10.1002/best.201900004, which has been published in final form at https://doi.org/10.1002/best.201900004 VL - 2019 ER - TY - CHAP A1 - Dokhanchi, Najmeh Sadat ED - Arnold, Jörg T1 - Acoustic travel time tomography: Applicability of an array of directional sound sources N2 - The technique of Acoustic travel-time TOMography (ATOM) allows for measuring the distribution of air temperatures throughout the entire room based on the determined sound-travel-times of early reflections, currently up to second order reflections. The number of detected early reflections in the room impulse response (RIR) which stands for the desired sound paths inside the room, has a significant impact on the resolution of reconstructed temperatures. This study investigates the possibility of utilizing an array of directional sound sources for ATOM measurements instead of a single omnidirectional loudspeaker used in the previous studies [1–3]. The developed measurement setup consists of two directional sound sources placed near the edge of the floor in the climate chamber of the Bauhaus-University Weimar and one omnidirectional receiver at center of the room near the ceiling. In order to compensate for the reduced number of sound paths when using directional sound sources, it is proposed to take high-energy early reflections up to third order into account. For this purpose, the simulated travel times up to third-order image sources were implemented in the image source model (ISM) algorithm, by which these early reflections can be detected effectively for air temperature reconstructions. To minimize the uncertainties of travel-times estimation due to the positioning of the sound transducers inside the room, measurements were conducted to determine the exact emitting point of the utilized sound source i.e. its acoustic center (AC). For these measurements, three types of excitation signals (MLS, linear and logarithmic chirp signals) with various frequency ranges were used considering that the acoustic center of a sound source is a frequency dependent parameter [4]. Furthermore, measurements were conducted to determine an optimum excitation signal based on the given condition of the ATOM measurement set-up which defines an optimum method for the RIR estimation correspondingly. Finally, the uncertainty of the measuring system utilizing an array of directional sound sources was analyzed. KW - Bauphysik KW - Akustische Laufzeit-Tomographie KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46589 UR - https://www.dega-akustik.de/publikationen/online-proceedings N1 - This conference paper has been submitted to the DAGA 2022. Thus, the original paper first is published in the "Fortschritte der Akustik - DAGA 2022" ER - TY - CHAP A1 - Dokhanchi, Najmeh Sadat ED - Arnold, Jörg T1 - Reconstruction of the indoor air temperature distribution using acoustic travel-time tomography N2 - Acoustic travel-time tomography (ATOM) is being increasingly considered recently as a remote sensing methodology to determine the indoor air temperatures distribution. It employs the relationship between the sound velocities along sound-paths and their related travel-times through measured room-impulse-response (RIR). Thus, the precise travel-time estimation is of critical importance which can be performed by applying an analysis time-window method. In this study, multiple analysis time-windows with different lengths are proposed to overcome the challenge of accurate detection of the travel-times at RIR. Hence, the ATOM-temperatures distribution has been measured at the climate chamber lab of the Bauhaus-University Weimar. As a benchmark, the temperatures of NTC thermistors are compared to the reconstructed temperatures derived from the ATOM technique illustrating this technique can be a reliable substitute for traditional thermal sensors. The numerical results indicate that the selection of an appropriate analysis time-window significantly enhances the accuracy of the reconstructed temperatures distribution. KW - Bauphysik KW - Akustische Laufzeit-Tomographie KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46593 ER - TY - THES A1 - Dokhanchi, Najmeh Sadat T1 - Measurement of the Indoor Air Temperature Distribution using Acoustic Travel-Time Tomography N2 - One of the main criteria determining the thermal comfort of occupants is the air temperature. To monitor this parameter, a thermostat is traditionally mounted in the indoor environment for instance in office rooms in the workplaces, or directly on the radiator or in another location in a room. One of the drawbacks of this conventional method is the measurement at a certain location instead of the temperature distribution in the entire room including the occupant zone. As a result, the climatic conditions measured at the thermostat point may differ from those at the user's location. This not only negatively impacts the thermal comfort assessment but also leads to a waste of energy due to unnecessary heating and cooling. Moreover, for measuring the distribution of the air temperature under laboratory conditions, multiple thermal sensors should be installed in the area under investigation. This requires high effort in both installation and expense. To overcome the shortcomings of traditional sensors, Acoustic travel-time TOMography (ATOM) offers an alternative based on measuring the transmission sound velocity signals. The basis of the ATOM technique is the first-order dependency of the sound velocity on the medium's temperature. The average sound velocity, along the propagation paths, can be determined by travel-times estimation of a defined acoustic signal between transducers. After the travel-times collection, the room is divided into several volumetric grid cells, i.e. voxels, whose sizes are defined depending on the dimension of the room and the number of sound paths. Accordingly, the spatial air temperature in each voxel can be determined using a suitable tomographic algorithm. Recent studies indicate that despite the great potential of this technique to detect room climate, few experiments have been conducted. This thesis aims to develop the ATOM technique for indoor climatic applications while coupling the analysis methods of tomography and room acoustics. The method developed in this thesis uses high-energy early reflections in addition to the direct paths between transducers for travel time estimation. In this way, reflections can provide multiple sound paths that allow the room coverage to be maintained even when a few or even only one transmitter and receiver are used. In the development of the ATOM measurement system, several approaches have been employed, including the development of numerical methods and simulations and conducting experimental measurements, each of which has contributed to the improvement of the system's accuracy. In order to effectively separate the early reflections and ensure adequate coverage of the room with sound paths, a numerical method was developed based on the optimization of the coordinates of the sound transducers in the test room. The validation of the optimal positioning method shows that the reconstructed temperatures were significantly improved by placing the transducers at the optimal coordinates derived from the developed numerical method. The other numerical method developed is related to the selection of the travel times of the early reflections. Accordingly, the detection of the travel times has been improved by adjusting the lengths of the multiple analysis time-windows according to the individual travel times in the reflectogram of the room impulse response. This can reduce the probability of trapping faulty travel times in the analysis time-windows. The simulation model used in this thesis is based on the image source model (ISM) method for simulating the theoretical travel times of early reflection sound paths. The simulation model was developed to simulate the theoretical travel times up to third-order reflections. The empirical measurements were carried out in the climate lab of the Chair of Building Physics under different boundary conditions, i.e., combinations of different room air temperatures under both steady-state and transient conditions, and different measurement setups. With the measurements under controllable conditions in the climate lab, the validity of the developed numerical methods was confirmed. In this thesis, the performance of the ATOM measurement system was evaluated using two measurement setups. The setup for the initial investigations consists of an omnidirectional receiver and a near omnidirectional sound source, keeping the number of transducers as few as possible. This has led to accurately identify the sources of error that could occur in each part of the measuring system. The second measurement setup consists of two directional sound sources and one omnidirectional receiver. This arrangement of transducers allowed a higher number of well-detected travel times for tomography reconstruction, a better travel time estimation due to the directivity of the sound source, and better space utilization. Furthermore, this new measurement setup was tested to determine an optimal selection of the excitation signal. The results showed that for the utilized setup, a linear chirp signal with a frequency range of 200 - 4000 Hz and a signal duration of t = 1 s represents an optimal selection with respect to the reliability of the measured travel times and higher signal-to-noise ratio (SNR). To evaluate the performance of the measuring setups, the ATOM temperatures were always compared with the temperatures of high-resolution NTC thermistors with an accuracy of ±0.2 K. The entire measurement program, including acoustic measurements, simulation, signal processing, and visualization of measurement results are performed in MATLAB software. In addition, to reduce the uncertainty of the positioning of the transducers, the acoustic centre of the loudspeaker was determined experimentally for three types of excitation signals, namely MLS (maximum length sequence) signals with different lengths and duration, linear and logarithmic chirp signals with different defined frequency ranges. For this purpose, the climate lab was converted into a fully anechoic chamber by attaching absorption panels to the entire surfaces of the room. The measurement results indicated that the measurement of the acoustic centre of the sound source significantly reduces the displacement error of the transducer position. Moreover, to measure the air temperature in an occupied room, an algorithm was developed that can convert distorted signals into pure reference signals using an adaptive filter. The measurement results confirm the validity of the approach for a temperature interval of 4 K inside the climate lab. Accordingly, the accuracy of the reconstructed temperatures indicated that ATOM is very suitable for measuring the air temperature distribution in rooms. T3 - Schriftenreihe der Professur Bauphysik - 8 KW - Bauphysik KW - Acoustic Travel-Time Tomography KW - Bauklimatik Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230414-49567 SN - 978-3-00-075344-2 (print) ER - TY - CHAP A1 - Dokhanchi, Najmeh Sadat A1 - Arnold, Jörg A1 - Vogel, Albert A1 - Völker, Conrad T1 - Acoustic Travel-Time Tomography: Optimal Positioning of Transceiver and Maximal Sound-Ray Coverage of the Room T2 - Fortschritte der Akustik - DAGA 2019 N2 - Acoustic travel-time tomography (ATOM) determines the distribution of the temperature in a propagation medium by measuring the travel-time of acoustic signals between transmitters and receivers. To employ ATOM for indoor climate measurements, the impulse responses have been measured in the climate chamber lab of the Bauhaus-University Weimar and compared with the theoretical results of its image source model (ISM). A challenging task is distinguishing the reflections of interest in the reflectogram when the sound rays have similar travel-times. This paper presents a numerical method to address this problem by finding optimal positions of transmitter and receiver, since they have a direct impact on the distribution of travel times. These optimal positions have the minimum number of simultaneous arrival time within a threshold level. Moreover, for the tomographic reconstruction, when some of the voxels remain empty of sound-rays, it leads to inaccurate determination of the air temperature within those voxels. Based on the presented numerical method, the number of empty tomographic voxels are minimized to ensure the best sound-ray coverage of the room. Subsequently, a spatial temperature distribution is estimated by simultaneous iterative reconstruction technique (SIRT). The experimental set-up in the climate chamber verifies the simulation results. KW - Bauphysik KW - Acoustic Travel-Time Tomography KW - Bauklimatik KW - Akustische Tomographie Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20190408-38778 UR - https://www.dega-akustik.de/publikationen/online-proceedings/ N1 - This conference paper has been submitted to the DAGA 2019. Thus, the original paper first is published in the "Fortschritte der Akustik - DAGA 2019" ER -