TY - JOUR A1 - Alkam, Feras A1 - Lahmer, Tom T1 - A robust method of the status monitoring of catenary poles installed along high-speed electrified train tracks JF - Results in Engineering N2 - Electric trains are considered one of the most eco-friendly and safest means of transportation. Catenary poles are used worldwide to support overhead power lines for electric trains. The performance of the catenary poles has an extensive influence on the integrity of the train systems and, consequently, the connected human services. It became a must nowadays to develop SHM systems that provide the instantaneous status of catenary poles in- service, making the decision-making processes to keep or repair the damaged poles more feasible. This study develops a data-driven, model-free approach for status monitoring of cantilever structures, focusing on pre-stressed, spun-cast ultrahigh-strength concrete catenary poles installed along high-speed train tracks. The pro-posed approach evaluates multiple damage features in an unfied damage index, which leads to straightforward interpretation and comparison of the output. Besides, it distinguishes between multiple damage scenarios of the poles, either the ones caused by material degradation of the concrete or by the cracks that can be propagated during the life span of the given structure. Moreover, using a logistic function to classify the integrity of structure avoids the expensive learning step in the existing damage detection approaches, namely, using the modern machine and deep learning methods. The findings of this study look very promising when applied to other types of cantilever structures, such as the poles that support the power transmission lines, antenna masts, chimneys, and wind turbines. KW - Fahrleitung KW - Catenary poles KW - SHM KW - Model-free status monitoring KW - Sigmoid function KW - High-speed electric train KW - Schaden KW - OA-Publikationsfonds2021 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211011-45212 UR - https://www.sciencedirect.com/science/article/pii/S2590123021000906?via%3Dihub VL - 2021 IS - volume 12, article 100289 SP - 1 EP - 8 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alkam, Feras A1 - Lahmer, Tom T1 - Eigenfrequency-Based Bayesian Approach for Damage Identification in Catenary Poles JF - Infrastructures N2 - This study proposes an efficient Bayesian, frequency-based damage identification approach to identify damages in cantilever structures with an acceptable error rate, even at high noise levels. The catenary poles of electric high-speed train systems were selected as a realistic case study to cover the objectives of this study. Compared to other frequency-based damage detection approaches described in the literature, the proposed approach is efficiently able to detect damages in cantilever structures to higher levels of damage detection, namely identifying both the damage location and severity using a low-cost structural health monitoring (SHM) system with a limited number of sensors; for example, accelerometers. The integration of Bayesian inference, as a stochastic framework, in the proposed approach, makes it possible to utilize the benefit of data fusion in merging the informative data from multiple damage features, which increases the quality and accuracy of the results. The findings provide the decision-maker with the information required to manage the maintenance, repair, or replacement procedures. KW - Fahrleitung KW - Schaden KW - Fahrleitungsmast KW - Schadenserkennung KW - vibration-based damage identification KW - Bayesian inference Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20210510-44256 UR - https://www.mdpi.com/2412-3811/6/4/57 VL - 2021 IS - Volume 6, issue 4, article 57 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Allen, Stan T1 - After mechanical reproduction N2 - Wissenschaftliches Kolloquium vom 27. bis 30. Juni 1996 in Weimar an der Bauhaus-Universität zum Thema: ‚Techno-Fiction. Zur Kritik der technologischen Utopien' T3 - Thesis // Bauhaus-Universität - 43.1997,1-2/61-64 KW - Architektur KW - Technologie KW - Fiktion KW - Bauhaus-Kolloquium KW - Weimar KW - 1996 Y1 - 1997 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-11686 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Hilbel, Rebecca A1 - Völker, Conrad T1 - ENVI-met validation data accompanied with simulation data of the impact of facade greening on the urban microclimate JF - Data in Brief N2 - This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model. The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1]. KW - Messung KW - Measurements KW - Simulations KW - ENVI-met KW - Living wall KW - Green facade KW - Simulation KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220511-46455 UR - https://www.sciencedirect.com/science/article/pii/S2352340922004048#! VL - 2022 IS - Volume 42, article 108200 SP - 1 EP - 13 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Voelker, Conrad T1 - The effect of a living wall system designated for greywater treatment on the hygrothermal performance of the facade JF - Energy and Buildings N2 - Besides their multiple known benefits regarding urban microclimate, living walls can be used as decentralized stand-alone systems to treat greywater locally at the buildings. While this offers numerous environmental advantages, it can have a considerable impact on the hygrothermal performance of the facade as such systems involve bringing large quantities of water onto the facade. As it is difficult to represent complex entities such as plants in the typical simulation tools used for heat and moisture transport, this study suggests a new approach to tackle this challenge by coupling two tools: ENVI-Met and Delphin. ENVI-Met was used to simulate the impact of the plants to determine the local environmental parameters at the living wall. Delphin, on the other hand, was used to conduct the hygrothermal simulations using the local parameters calculated by ENVI-Met. Four wall constructions were investigated in this study: an uninsulated brick wall, a precast concrete plate, a sandy limestone wall, and a double-shell wall. The results showed that the living wall improved the U-value, the exterior surface temperature, and the heat flux through the wall. Moreover, the living wall did not increase the risk of moisture in the wall during winter and eliminated the risk of condensation. KW - Feuchteleitung KW - Diffusionswärme KW - Heat transport KW - Moisture transport KW - Living wall KW - Delphin KW - ENVI-Met Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20240116-65299 UR - https://www.sciencedirect.com/science/article/pii/S0378778821009956 VL - 2022 IS - volume 255, article 111711 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Schälte, Gereon A1 - Schneeweiß, Mario A1 - Becher, Lia A1 - Pollack, Moritz A1 - Gena, Amayu Wakoya A1 - Schweiker, Marcel A1 - Hartmann, Maria A1 - Voelker, Conrad A1 - Rossaint, Rolf A1 - Irrgang, Matthias T1 - The Spread of Exhaled Air and Aerosols during Physical Exercise JF - Journal of Clinical Medicine N2 - Physical exercise demonstrates a special case of aerosol emission due to its associated elevated breathing rate. This can lead to a faster spread of airborne viruses and respiratory diseases. Therefore, this study investigates cross-infection risk during training. Twelve human subjects exercised on a cycle ergometer under three mask scenarios: no mask, surgical mask, and FFP2 mask. The emitted aerosols were measured in a grey room with a measurement setup equipped with an optical particle sensor. The spread of expired air was qualitatively and quantitatively assessed using schlieren imaging. Moreover, user satisfaction surveys were conducted to evaluate the comfort of wearing face masks during training. The results indicated that both surgical and FFP2 masks significantly reduced particles emission with a reduction efficiency of 87.1% and 91.3% of all particle sizes, respectively. However, compared to surgical masks, FFP2 masks provided a nearly tenfold greater reduction of the particle size range with long residence time in the air (0.3–0.5 μm). Furthermore, the investigated masks reduced exhalation spreading distances to less than 0.15 m and 0.1 m in the case of the surgical mask and FFP2 mask, respectively. User satisfaction solely differed with respect to perceived dyspnea between no mask and FFP2 mask conditions. KW - Sport KW - Training KW - Fahrradergometer KW - sport KW - training KW - cycle ergometer KW - schlieren imaging KW - particles concentration KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230208-49262 UR - https://www.mdpi.com/2077-0383/12/4/1300 VL - 2023 IS - Volume 12, issue 4, article 1300 PB - Basel CY - MDPI ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance assessment of a ductless personalized ventilation system using a validated CFD model JF - Journal of Building Performance Simulation N2 - The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model. KW - Ventilation KW - Validierung KW - Strömungsmechanik KW - Raumklima KW - personalized ventilation KW - validation KW - computational fluid dynamics KW - thermal comfort KW - indoor air quality Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20190218-38500 UR - https://www.tandfonline.com/doi/full/10.1080/19401493.2018.1431806 N1 - Copyright 2018 Taylor & Francis Group and the International Building Performance Simulation Association (IBPSA). This article may be downloaded for personal use only. Any other use requires prior permission of the authors and Taylor & Francis Group. This is an Accepted Manuscript of an article published by Taylor & Francis in the Journal of Building Performance Simulation 11 (6), 689–704 (2018) and may be found at https://doi.org/10.1080/19401493.2018.1431806 VL - 2018 IS - 11, Heft 6 SP - 689 EP - 704 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Qualitative evaluation of the flow supplied by personalized ventilation using schlieren imaging and thermography JF - Building and Environment N2 - Personalized ventilation (PV) is a mean of delivering conditioned outdoor air into the breathing zone of the occupants. This study aims to qualitatively investigate the personalized flows using two methods of visualization: (1) schlieren imaging using a large schlieren mirror and (2) thermography using an infrared camera. While the schlieren imaging was used to render the velocity and mass transport of the supplied flow, thermography was implemented to visualize the air temperature distribution induced by the PV. Both studies were conducted using a thermal manikin to simulate an occupant facing a PV outlet. As a reference, the flow supplied by an axial fan and a cased axial fan was visualized with the schlieren system as well and compared to the flow supplied by PV. Schlieren visualization results indicate that the steady, low-turbulence flow supplied by PV was able to penetrate the thermal convective boundary layer encasing the manikin's body, providing clean air for inhalation. Contrarily, the axial fan diffused the supplied air over a large target area with high turbulence intensity; it only disturbed the convective boundary layer rather than destroying it. The cased fan supplied a flow with a reduced target area which allowed supplying more air into the breathing zone compared to the fan. The results of thermography visualization showed that the supplied cool air from PV penetrated the corona-shaped thermal boundary layer. Furthermore, the supplied air cooled the surface temperature of the face, which indicates the large impact of PV on local thermal sensation and comfort. KW - Bildverarbeitung KW - Photothermische Methode KW - Visualisierung KW - Belüftung KW - Lüftungsanlage KW - Schlieren imaging KW - Thermography KW - Visualization KW - Personalized ventilation KW - Axial fan Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211008-45117 UR - https://www.sciencedirect.com/science/article/abs/pii/S0360132319306602?via%3Dihub N1 - This is the accepted manuscript of the article published by Elsevier in Building and Environment 167 (2020) 106450, which can be found at https://doi.org/10.1016/j.buildenv.2019.106450. VL - 2020 IS - Volume 167, article 106450 PB - Elsevier CY - New York ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Der Kühlungseffekt der personalisierten Lüftung T1 - The cooling effect of personalized ventilation systems JF - Bauphysik N2 - Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden. N2 - Personalized ventilation (PV) can improve thermal comfort and inhaled air quality by supplying air to each workstation separately. This study investigates the impact of PV on the thermal state of the users under summer boundary conditions. Two approaches to evaluating the cooling effect of PV were investigated, based on equivalent temperature and based on thermal sensation. Both approaches implemented measured and simulated values of the cooling effect of PV. Before conducting the simulations, the numerical model was first validated against measured data collected in a climate chamber equipped with a thermal manikin. Results indicated that the thermal sensation approach can be more suitable for evaluating the cooling effect of PV due to the complex physiological factors it considers. KW - Lüftung KW - Strömung KW - Raumklima KW - Temperatur KW - personalized ventilation KW - computational fluid dynamics KW - Simulation KW - personalisierte Lüftung KW - äquivalente Temperatur KW - thermisches Empfinden Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20201020-42723 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.202000018 N1 - © 2020 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 42 (2020), Heft 5, 218-225, DOI: 10.1002/bapi.202000018 VL - 2020 IS - volume 42, issue 5 SP - 218 EP - 225 PB - Ernst & Sohn bei John Wiley & Sons CY - Hoboken ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations JF - Indoor Air N2 - The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant. KW - Behaglichkeit KW - Raumklima KW - Strömungsmechanik KW - Fluid KW - computational fluid dynamics KW - desk fan KW - ductless personalized ventilation KW - IAQ KW - thermal comfort Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200422-41407 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12672 VL - 2020 PB - John Wiley & Sons Ltd ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation? JF - Indoor Air N2 - This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off. KW - Strömungsmechanik KW - Kontamination KW - Belüftung KW - Luftqualität KW - computational fluid dynamics KW - cross-contamination KW - ductless personalized ventilation KW - indoor air quality KW - tracer gas Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200805-42072 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12720 VL - 2020 PB - John Wiley & Sons Ltd ER - TY - JOUR A1 - Amani, Jafar A1 - Saboor Bagherzadeh, Amir A1 - Rabczuk, Timon T1 - Error estimate and adaptive refinement in mixed discrete least squares meshless method JF - Mathematical Problems in Engineering N2 - The node moving and multistage node enrichment adaptive refinement procedures are extended in mixed discrete least squares meshless (MDLSM) method for efficient analysis of elasticity problems. In the formulation of MDLSM method, mixed formulation is accepted to avoid second-order differentiation of shape functions and to obtain displacements and stresses simultaneously. In the refinement procedures, a robust error estimator based on the value of the least square residuals functional of the governing differential equations and its boundaries at nodal points is used which is inherently available from the MDLSM formulation and can efficiently identify the zones with higher numerical errors. The results are compared with the refinement procedures in the irreducible formulation of discrete least squares meshless (DLSM) method and show the accuracy and efficiency of the proposed procedures. Also, the comparison of the error norms and convergence rate show the fidelity of the proposed adaptive refinement procedures in the MDLSM method. KW - Elastizität KW - Fehlerabschätzung KW - MDLSM method Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170413-31181 ER - TY - JOUR A1 - Amirinasab, Mehdi A1 - Shamshirband, Shahaboddin A1 - Chronopoulos, Anthony Theodore A1 - Mosavi, Amir A1 - Nabipour, Narjes T1 - Energy‐Efficient Method for Wireless Sensor Networks Low‐Power Radio Operation in Internet of Things JF - electronics N2 - The radio operation in wireless sensor networks (WSN) in Internet of Things (IoT)applications is the most common source for power consumption. Consequently, recognizing and controlling the factors affecting radio operation can be valuable for managing the node power consumption. Among essential factors affecting radio operation, the time spent for checking the radio is of utmost importance for monitoring power consumption. It can lead to false WakeUp or idle listening in radio duty cycles and ContikiMAC. ContikiMAC is a low‐power radio duty‐cycle protocol in Contiki OS used in WakeUp mode, as a clear channel assessment (CCA) for checking radio status periodically. This paper presents a detailed analysis of radio WakeUp time factors of ContikiMAC. Furthermore, we propose a lightweight CCA (LW‐CCA) as an extension to ContikiMAC to reduce the Radio Duty‐Cycles in false WakeUps and idle listening though using dynamic received signal strength indicator (RSSI) status check time. The simulation results in the Cooja simulator show that LW‐CCA reduces about 8% energy consumption in nodes while maintaining up to 99% of the packet delivery rate (PDR). KW - Internet der Dinge KW - Internet of things KW - wireless sensor networks KW - ContikiMAC KW - energy efficiency KW - duty-cycles KW - clear channel assessments KW - fog computing KW - smart sensors KW - signal processing KW - received signal strength indicator KW - OA-Publikationsfonds2020 KW - RSSI Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200213-40954 UR - https://www.mdpi.com/2079-9292/9/2/320 VL - 2020 IS - volume 9, issue 2, 320 PB - MDPI ER - TY - JOUR A1 - Anders, Frauke A1 - König, Reinhard T1 - Analyse und Generierung von Straßennetzwerken mittels graphenbasierter Methoden N2 - Der vorliegende Beitrag ist in zwei thematische Teilebereiche gegliedert. Der erste Teil beschäftigt sich mit der Analyse von Graphen, insbesondere von Graphen, die Straßennetzwerke repräsentieren. Hierzu werden Methoden aus der Graphentheorie angewendet und Kenngrößen aus der Space Syntax Methode ausgewertet. Ein Framework, welches basierend auf der Graphentheorie in Architektur und Stadtplanung Einzug gehalten hat, ist die Space Syntax Methode. Sie umfasst die Ableitung unterschiedlicher Kenngrößen eines Graphen bzw. Netzwerkes, wodurch eine Analyse für architektonische und stadtplanerische Zwecke ermöglicht wird. Der zweite Teil dieses Berichts beschäftigt sich mit der Generierung von Graphen, insbe-sondere der von Straßennetzwerkgraphen. Die generativen Methoden basieren zum Teil auf den gewonnenen Erkenntnissen der Analyse von Straßennetzwerken. Es werden unterschiedliche Ansätze untersucht, um verschiedene Parameterwerte zur Generierung von Straßengraphen festzulegen. Als Ergebnis der Arbeiten ist ein Softwaretool entstanden, welches es erlaubt, auf Grundlage einer Voronoi-Tesselierung realistische Straßennetzwerkgraphen zu erzeugen. T3 - Arbeitspapiere Informatik in der Architektur - Nr. 7 KW - Graph KW - Straßennetzwerk analyse, graph-basierte generative Methoden Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20120509-16514 UR - http://infar.architektur.uni-weimar.de/service/drupal-infar/Arbeitspapiere ER - TY - JOUR A1 - Anic, Filip A1 - Penava, Davorin A1 - Sarhosis, Vasilis A1 - Abrahamczyk, Lars T1 - Development and Calibration of a 3D Micromodel for Evaluation of Masonry Infilled RC Frame Structural Vulnerability to Earthquakes JF - Geosciences N2 - Within the scope of literature, the influence of openings within the infill walls that are bounded by a reinforced concrete frame and excited by seismic drift forces in both in- and out-of-plane direction is still uncharted. Therefore, a 3D micromodel was developed and calibrated thereafter, to gain more insight in the topic. The micromodels were calibrated against their equivalent physical test specimens of in-plane, out-of-plane drift driven tests on frames with and without infill walls and openings, as well as out-of-plane bend test of masonry walls. Micromodels were rectified based on their behavior and damage states. As a result of the calibration process, it was found that micromodels were sensitive and insensitive to various parameters, regarding the model’s behavior and computational stability. It was found that, even within the same material model, some parameters had more effects when attributed to concrete rather than on masonry. Generally, the in-plane behavior of infilled frames was found to be largely governed by the interface material model. The out-of-plane masonry wall simulations were governed by the tensile strength of both the interface and masonry material model. Yet, the out-of-plane drift driven test was governed by the concrete material properties. KW - Verwundbarkeit KW - Ausfachung KW - Stahlbeton KW - RC frames KW - unreinforced masonry infill walls KW - openings KW - structural vulnerability KW - out-of-plane seismic load KW - OA-Publikationsfonds2021 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211202-45370 UR - https://www.mdpi.com/2076-3263/11/11/468 VL - 2021 IS - Voume 11, issue 11, article 468 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ansari, Meisam A1 - Tartaglione, Fabiola A1 - Könke, Carsten T1 - Experimental Validation of Dynamic Response of Small-Scale Metaconcrete Beams at Resonance Vibration JF - materials N2 - Structures and their components experience substantially large vibration amplitudes at resonance, which can cause their failure. The scope of this study is the utilization of silicone-coated steel balls in concrete as damping aggregates to suppress the resonance vibration. The heavy steel cores oscillate with a frequency close to the resonance frequency of the structure. Due to the phase difference between the vibrations of the cores and the structure, the cores counteract the vibration of the structure. The core-coating inclusions are randomly distributed in concrete similar to standard aggregates. This mixture is referred to as metaconcrete. The main goal of this work is to validate the ability of the inclusions to suppress mechanical vibration through laboratory experiments. For this purpose, two small-scale metaconcrete beams were cast and tested. In a free vibration test, the metaconcrete beams exhibited a larger damping ratio compared to a similar beam cast from conventional concrete. The vibration amplitudes of the metaconcrete beams at resonance were measured with a frequency sweep test. In comparison with the conventional concrete beam, both metaconcrete beams demonstrated smaller vibration amplitudes. Both experiments verified an improvement in the dynamic response of the metaconcrete beams at resonance vibration. KW - Beton KW - metaconcrete KW - Schwingungsdämpfung KW - damping aggregate KW - vibration absorber KW - free vibration test KW - frequency sweep test Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230818-64154 UR - https://www.mdpi.com/1996-1944/16/14/5029 VL - 2023 IS - volume 16, issue 14, article 5029 SP - 1 EP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ansari, Meisam A1 - Zacharias, Christin A1 - Könke, Carsten T1 - Metaconcrete: An Experimental Study on the Impact of the Core-Coating Inclusions on Mechanical Vibration JF - materials N2 - Resonance vibration of structures is an unpleasant incident that can be conventionally avoided by using a Tuned Mass Damper (TMD). The scope of this paper contains the utilization of engineered inclusions in concrete as damping aggregates to suppress resonance vibration similar to a TMD. The inclusions are composed of a stainless-steel core with a spherical shape coated with silicone. This configuration has been the subject of several studies and it is best known as Metaconcrete. This paper presents the procedure of a free vibration test conducted with two small-scaled concrete beams. The beams exhibited a higher damping ratio after the core-coating element was secured to them. Subsequently, two meso-models of small-scaled beams were created: one representing conventional concrete and the other representing concrete with the core-coating inclusions. The frequency response curves of the models were obtained. The change in the response peak verified the ability of the inclusions to suppress the resonance vibration. This study concludes that the core-coating inclusions can be utilized in concrete as damping aggregates. KW - Beton KW - Schwingungsdämpfung KW - metaconcrete KW - damping aggregate KW - vibration absorber Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230315-49370 UR - https://www.mdpi.com/1996-1944/16/5/1836 VL - 2023 IS - Volume 16, Issue 5, article 1836 SP - 1 EP - 18 PB - MDPI CY - Basel ER - TY - JOUR A1 - Arnold, Robert A1 - Kraus, Matthias ED - Pham, Duc T1 - On the nonstationary identification of climate-influenced loads for the semi-probabilistic approach using measured and projected data JF - Cogent Engineering N2 - A safe and economic structural design based on the semi-probabilistic concept requires statistically representative safety elements, such as characteristic values, design values, and partial safety factors. Regarding climate loads, the safety levels of current design codes strongly reflect experiences based on former measurements and investigations assuming stationary conditions, i.e. involving constant frequencies and intensities. However, due to climate change, occurrence of corresponding extreme weather events is expected to alter in the future influencing the reliability and safety of structures and their components. Based on established approaches, a systematically refined data-driven methodology for the determination of design parameters considering nonstationarity as well as standardized targets of structural reliability or safety, respectively, is therefore proposed. The presented procedure picks up fundamentals of European standardization and extends them with respect to nonstationarity by applying a shifting time window method. Taking projected snow loads into account, the application of the method is exemplarily demonstrated and various influencing parameters are discussed. KW - Reliabilität KW - Extreme value distribution KW - climate loads KW - nonstationarity KW - semi-probabilistic concept KW - First Order Reliability Method KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20221117-47363 UR - https://doi.org/10.1080/23311916.2022.2143061 VL - 2022 IS - Volume 9, issue 1, article 2143061 SP - 1 EP - 26 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Artus, Mathias A1 - Alabassy, Mohamed Said Helmy A1 - Koch, Christian T1 - A BIM Based Framework for Damage Segmentation, Modeling, and Visualization Using IFC JF - Applied Sciences N2 - Paper-based data acquisition and manual transfer between incompatible software or data formats during inspections of bridges, as done currently, are time-consuming, error-prone, cumbersome, and lead to information loss. A fully digitized workflow using open data formats would reduce data loss, efforts, and the costs of future inspections. On the one hand, existing studies proposed methods to automatize data acquisition and visualization for inspections. These studies lack an open standard to make the gathered data available for other processes. On the other hand, several studies discuss data structures for exchanging damage information among different stakeholders. However, those studies do not cover the process of automatic data acquisition and transfer. This study focuses on a framework that incorporates automatic damage data acquisition, transfer, and a damage information model for data exchange. This enables inspectors to use damage data for subsequent analyses and simulations. The proposed framework shows the potentials for a comprehensive damage information model and related (semi-)automatic data acquisition and processing. KW - Building Information Modeling KW - Brücke KW - Inspektion KW - Maschinelles Lernen KW - Bildverarbeitung KW - Building Information Modeling KW - Bridge KW - Inspection KW - Damage Segmentation KW - Machine Learning KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220314-46059 UR - https://www.mdpi.com/2076-3417/12/6/2772 VL - 2022 IS - volume 12, issue 6, article 2772 SP - 1 EP - 24 PB - MDPI CY - Basel ER -