TY - JOUR A1 - Êirinhevsky, V. V. A1 - Dîkhnyak, B. M. A1 - Êirichevsky, R. V. A1 - Êîzub, Y. G. T1 - Determination of the Temperature of Dissipative Warming and Parameters of Fracture in Elastomers with using of Singular Finite Elements N2 - For modeling of singular fields of stresses and deformations in elasters with a crack is offered to use of three-dimesional a special finite element. Weak compessible of elasters is taken into account on the basis of threefold approximation of fields of displacements, deformations and function of volume change. At intensive cyclic loading of the elastomer constructions with a crack it is necessary to take into account warming and large deformations at the crack top. The stress-deformed state elasters with a crack is determined from the decision of a nonlinear problem by a modified method Newton-Kantorovich. Account stress intensity factors for a rectangular plate with a various arrangement of a through crack is executed. Process of development of a surface crack and dissipative warming in prismatic a element of shift is investigated. KW - Elastomer KW - Temperatur KW - Finite-Elemente-Methode Y1 - 1997 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-5471 ER - TY - THES A1 - Arifin, Yulian Firmana T1 - Thermo-hydro-mechanical behavior of compacted bentonite-sand mixtures: an experimental study N2 - Heat, gas, and leachate are primary by-products of landfill processes in municipal solid waste landfills. In nuclear waste repository, temperature of the waste also raises due to radioactivity processes. Temperature increase in the repository induces hydro-mechanical processes of its sealing material. Moderate to high temperature is expected to be encountered in the field situation. In this thesis, a study on the thermo-hydro-mechanical behavior of compacted bentonite-sand mixtures which are among the materials proposed to be used as sealing material for landfills and hazardous waste repository is presented. Mixtures of a calcium-type bentonite, Calcigel, and quartz sand were used in this study. Series of tests including suction and swelling pressure measurement, drying-wetting under unconfined and confined conditions were conducted at a moderately high temperature. Tests at room temperature including basic and physico-chemical characterization, microstructure and fabric studies, and osmotic suction were conducted in order to provide insight into understanding the hydro-mechanical processes taking place in the bentonite. The experimental data obtained are presented and compared to the result of the previous tests for the same material performed by other researchers at room temperature. The changes in hydro-mechanical behavior due to elevated temperature were analyzed and discussed based on the suction components of soil which are influenced by temperature. At the end, conclusions concerning the temperature effects on the hydro-mechanical behavior of the materials are drawn and suggestions for future studies are made. N2 - In Folge der Prozesse in den Siedlungsabfalldeponien entstehen Wärme, Gas und Sickerwasser als Nebenprodukte. In Deponien für nukleare Abfälle nimmt die Wärme in Abhängigkeit deren Radioaktivität zu. Aufgrund der Wärmeentwicklung im Abfall kommt es in dem die Kanister umgebenden Dichtelement zu Temperaturänderungen, was verschiedene hydro-mechanische Prozesse verursacht, die sowohl bei niedrigen als auch bei mäßig hohen Temperaturen stattfinden. In dieser Dissertation wird eine Studie über die Auswirkungen von Temperaturänderungen auf das hydro-mechanische Verhalten von Bentonit-Sand-Gemischen vorgestellt, welche ein mögliches Dichtungsmaterial für Verschlussbauwerke in Deponien für radioaktive Abfälle darstellen. In dieser Studie wurden Mischungen von Kalzium-Bentonit, genannt “Calcigel“, und Quarzsand verwendet. Es wurden bei mäßig hohen Temperaturen Versuchsreihen durchgeführt, die die Messung der Saugspannungen und des Quelldrucks, als auch die Ermittlung der Saugspannungs-Wassergehalts-Beziehung auf dem Trocknungs- sowie Bewässerungspfad bei behinderter und nicht behinderter Volumenänderung beinhalten. Des weiteren wurden bei Raumtemperatur Versuche zur Bestimmung der physiko-chemischen Eigenschaften sowie Untersuchungen zur Struktur und der osmotischen Saugspannung durchgeführt. Das Ziel dieser Untersuchungen war es, einen besseres Verständnis der innerhalb des Bentonits stattfindenden hydro-mechanischen Prozesse zu erlangen. Die experimentell gewonnenen Daten werden vorgestellt und mit Ergebnissen aus vorangegangenen Forschungsarbeiten am selben Material bei Raumtemperatur verglichen. Die beobachteten Änderungen im hydro-mechanischen Verhalten aufgrund der erhöhten Umgebungstemperatur werden analysiert und diskutiert, wobei besonderes Augenmerk auf die Materialkomponenten gelegt wird, deren Eigenschaften und Verhalten durch die Temperatur beeinflusst wird. T2 - Das thermo-hydromechanische Verhalten von verdichteten Bentonit-Sand-Mischungen: eine experimentelle Analyse KW - Temperatur KW - Bentonit-Sand KW - Quelldruck KW - hydromechanische Prozesse KW - Bentonite-sand KW - temperature KW - swelling pressure KW - drying-wetting Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20081006-14288 ER - TY - JOUR A1 - Hildebrand, Jörg A1 - Hecht, Kerstin A1 - Bliedtner, Jens A1 - Müller, Hartmut T1 - Laser Beam Polishing of Quartz Glass Surfaces JF - Physics Procedia N2 - The laser beam is a small, flexible and fast polishing tool. With laser radiation it is possible to finish many outlines or geometries on quartz glass surfaces in the shortest possible time. It's a fact that the temperature developing while polishing determines the reachable surface smoothing and, as a negative result, causes material tensions. To find out which parameters are important for the laser polishing process and the surface roughness respectively and to estimate material tensions, temperature simulations and extensive polishing experiments took place. During these experiments starting and machining parameters were changed and temperatures were measured contact-free. KW - Laser KW - Quarzglas KW - Polieren KW - Berührungslose Messung KW - Temperatur KW - Laser; quartz glass; polishing; temperature; residual stress; simulation; contactless measurement Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170418-31366 UR - http://www.sciencedirect.com/science/article/pii/S1875389211001350 SP - 452 EP - 461 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Der Kühlungseffekt der personalisierten Lüftung T1 - The cooling effect of personalized ventilation systems JF - Bauphysik N2 - Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden. N2 - Personalized ventilation (PV) can improve thermal comfort and inhaled air quality by supplying air to each workstation separately. This study investigates the impact of PV on the thermal state of the users under summer boundary conditions. Two approaches to evaluating the cooling effect of PV were investigated, based on equivalent temperature and based on thermal sensation. Both approaches implemented measured and simulated values of the cooling effect of PV. Before conducting the simulations, the numerical model was first validated against measured data collected in a climate chamber equipped with a thermal manikin. Results indicated that the thermal sensation approach can be more suitable for evaluating the cooling effect of PV due to the complex physiological factors it considers. KW - Lüftung KW - Strömung KW - Raumklima KW - Temperatur KW - personalized ventilation KW - computational fluid dynamics KW - Simulation KW - personalisierte Lüftung KW - äquivalente Temperatur KW - thermisches Empfinden Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20201020-42723 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.202000018 N1 - © 2020 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 42 (2020), Heft 5, 218-225, DOI: 10.1002/bapi.202000018 VL - 2020 IS - volume 42, issue 5 SP - 218 EP - 225 PB - Ernst & Sohn bei John Wiley & Sons CY - Hoboken ER -