TY - CHAP A1 - Völlmecke, Lars A1 - Schwendner, Sascha A1 - Ho, Ai Phien A1 - Fischer, Jens A1 - Seim, Werner T1 - Assessment of nailed connections in existing structures N2 - This paper presents the development of an assessment scheme for a visual qualitative evaluation of nailed connections in existing structures, such as board trusses. In terms of further use and preservation, a quick visual inspection will help to evaluate the quality of a structure regarding its load-bearing capacity and deformation behaviour. Tests of old and new nailed joints in combination with a rating scheme point out the correlation between the load-bearing capacity and condition of a joint. Old joints of comparatively good condition tend to exhibit better results than those of poor condition. Moreover, aged joints are generally more load-bearing than newly assembled ones. KW - Holzbau KW - Träger KW - nailed trusses KW - nailed constructions KW - Corrosion KW - Preservation KW - Re-use Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230609-63615 ER - TY - CHAP A1 - Zwölfer, Michael A1 - Thomas, Peter A1 - Schink, Claus-Jürgen A1 - Koch, Volker T1 - Life cycle optimized system solutions for densified housing with massive wood technology N2 - The objective of the joint project 'Life cycle optimised system solutions for densified housing with massive wood technology', short form Basys, was the development and application of an open building system for sustainable construction in a virtual enterprise. Four partners coming from building economy and a university institute developed the building system in a comprehensive planning process. By applying massive wood technology, most requirements of densified housing can be met and individual buildings can be produced on demand. KW - Lebenszyklus KW - Holzbau KW - Haus Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20111215-980 ER - TY - CHAP A1 - Schwendner, Sascha A1 - Völlmecke, Lars A1 - Ho, Ai Phien A1 - Fischer, Jens A1 - Seim, Werner T1 - TESTING OF CONNECTIONS TAKEN FROM OLD NAILED ROOF TRUSSES N2 - Experimental testing of nailed connections taken from old roof trusses is presented in this paper. To enable the further use and preservation of nailed roof trusses, it is important to understand how the nail corrosion and aging processes of steel and wood affect the load-bearing capacity and deformation behaviour of such structures. The hypothesis was investigated whether corroded nails allow an increase in load-bearing capacity. Several old and new joints were tested in a first test series, and the results were very promising regarding the initial assumption. However, more tests must be carried out to verify the results. KW - Holzbau KW - nailed trusses KW - nailed constructions KW - Corrosion KW - Preservation KW - Withdreawal Y1 - 2023 U6 - http://dx.doi.org/10.25643/bauhaus-universitaet.6362 ER -