TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Hilbel, Rebecca A1 - Völker, Conrad T1 - ENVI-met validation data accompanied with simulation data of the impact of facade greening on the urban microclimate JF - Data in Brief N2 - This dataset consists mainly of two subsets. The first subset includes measurements and simulation data conducted to validate the simulation tool ENVI-met. The measurements were conducted at the campus of the Bauhaus-University Weimar in Weimar, Germany and consisted of recording exterior air temperature, globe temperature, relative humidity, and wind velocity at 1.5 m at four points on four different days. After the measurements, the geometry of the campus was modelled and meshed; the simulations were conducted using the weather data of the measurements days with the aim of investigating the accuracy of the model. The second data subset consists of ENVI-met simulation data of the potential of facade greening in improving the outdoor environment and the indoor air temperature during heatwaves in Central European cities. The data consist of the boundary conditions and the simulation output of two simulation models: with and without facade greening. The geometry of the models corresponded to a residential buildings district in Stuttgart, Germany. The simulation output consisted of exterior air temperature, mean radiant temperature, relative humidity, and wind velocity at 12 different probe points in the model in addition to the indoor air temperature of an exemplary building. The dataset presents both vertical profiles of the probed parameters as well as the time series output of the five-day simulation duration. Both data subsets correspond to the investigations presented in the co-submitted article [1]. KW - Messung KW - Measurements KW - Simulations KW - ENVI-met KW - Living wall KW - Green facade KW - Simulation KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220511-46455 UR - https://www.sciencedirect.com/science/article/pii/S2352340922004048#! VL - 2022 IS - Volume 42, article 108200 SP - 1 EP - 13 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Voelker, Conrad T1 - The effect of a living wall system designated for greywater treatment on the hygrothermal performance of the facade JF - Energy and Buildings N2 - Besides their multiple known benefits regarding urban microclimate, living walls can be used as decentralized stand-alone systems to treat greywater locally at the buildings. While this offers numerous environmental advantages, it can have a considerable impact on the hygrothermal performance of the facade as such systems involve bringing large quantities of water onto the facade. As it is difficult to represent complex entities such as plants in the typical simulation tools used for heat and moisture transport, this study suggests a new approach to tackle this challenge by coupling two tools: ENVI-Met and Delphin. ENVI-Met was used to simulate the impact of the plants to determine the local environmental parameters at the living wall. Delphin, on the other hand, was used to conduct the hygrothermal simulations using the local parameters calculated by ENVI-Met. Four wall constructions were investigated in this study: an uninsulated brick wall, a precast concrete plate, a sandy limestone wall, and a double-shell wall. The results showed that the living wall improved the U-value, the exterior surface temperature, and the heat flux through the wall. Moreover, the living wall did not increase the risk of moisture in the wall during winter and eliminated the risk of condensation. KW - Feuchteleitung KW - Diffusionswärme KW - Heat transport KW - Moisture transport KW - Living wall KW - Delphin KW - ENVI-Met Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20240116-65299 UR - https://www.sciencedirect.com/science/article/pii/S0378778821009956 VL - 2022 IS - volume 255, article 111711 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Hartmann, Maria A1 - Völker, Conrad T1 - Hygrothermal simulation data of a living wall system for decentralized greywater treatment JF - Data in Brief N2 - This dataset presents the numerical analysis of the heat and moisture transport through a facade equipped with a living wall system designated for greywater treatment. While such greening systems provide many environmental benefits, they involve pumping large quantities of water onto the wall assembly, which can increase the risk of moisture in the wall as well as impaired energetic performance due to increased thermal conductivity with increased moisture content in the building materials. This dataset was acquired through numerical simulation using the coupling of two simulation tools, namely Envi-Met and Delphin. This coupling was used to include the complex role the plants play in shaping the near-wall environmental parameters in the hygrothermal simulations. Four different wall assemblies were investigated, each assembly was assessed twice: with and without the living wall. The presented data include the input and output parameters of the simulations, which were presented in the co-submitted article [1]. KW - Kupplung KW - Feuchteleitung KW - Heat transport KW - Moisture transport KW - Living wall KW - Wärmeübertragung KW - coupling KW - ENVI-Met KW - Delphin KW - OA-Publikationsfonds2022 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220106-45483 UR - https://www.sciencedirect.com/science/article/pii/S2352340921010167?via%3Dihub VL - 2022 IS - volume 40, article 107741 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alsaad, Hayder A1 - Schälte, Gereon A1 - Schneeweiß, Mario A1 - Becher, Lia A1 - Pollack, Moritz A1 - Gena, Amayu Wakoya A1 - Schweiker, Marcel A1 - Hartmann, Maria A1 - Voelker, Conrad A1 - Rossaint, Rolf A1 - Irrgang, Matthias T1 - The Spread of Exhaled Air and Aerosols during Physical Exercise JF - Journal of Clinical Medicine N2 - Physical exercise demonstrates a special case of aerosol emission due to its associated elevated breathing rate. This can lead to a faster spread of airborne viruses and respiratory diseases. Therefore, this study investigates cross-infection risk during training. Twelve human subjects exercised on a cycle ergometer under three mask scenarios: no mask, surgical mask, and FFP2 mask. The emitted aerosols were measured in a grey room with a measurement setup equipped with an optical particle sensor. The spread of expired air was qualitatively and quantitatively assessed using schlieren imaging. Moreover, user satisfaction surveys were conducted to evaluate the comfort of wearing face masks during training. The results indicated that both surgical and FFP2 masks significantly reduced particles emission with a reduction efficiency of 87.1% and 91.3% of all particle sizes, respectively. However, compared to surgical masks, FFP2 masks provided a nearly tenfold greater reduction of the particle size range with long residence time in the air (0.3–0.5 μm). Furthermore, the investigated masks reduced exhalation spreading distances to less than 0.15 m and 0.1 m in the case of the surgical mask and FFP2 mask, respectively. User satisfaction solely differed with respect to perceived dyspnea between no mask and FFP2 mask conditions. KW - Sport KW - Training KW - Fahrradergometer KW - sport KW - training KW - cycle ergometer KW - schlieren imaging KW - particles concentration KW - OA-Publikationsfonds2023 Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20230208-49262 UR - https://www.mdpi.com/2077-0383/12/4/1300 VL - 2023 IS - Volume 12, issue 4, article 1300 PB - Basel CY - MDPI ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance assessment of a ductless personalized ventilation system using a validated CFD model JF - Journal of Building Performance Simulation N2 - The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model. KW - Ventilation KW - Validierung KW - Strömungsmechanik KW - Raumklima KW - personalized ventilation KW - validation KW - computational fluid dynamics KW - thermal comfort KW - indoor air quality Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20190218-38500 UR - https://www.tandfonline.com/doi/full/10.1080/19401493.2018.1431806 N1 - Copyright 2018 Taylor & Francis Group and the International Building Performance Simulation Association (IBPSA). This article may be downloaded for personal use only. Any other use requires prior permission of the authors and Taylor & Francis Group. This is an Accepted Manuscript of an article published by Taylor & Francis in the Journal of Building Performance Simulation 11 (6), 689–704 (2018) and may be found at https://doi.org/10.1080/19401493.2018.1431806 VL - 2018 IS - 11, Heft 6 SP - 689 EP - 704 ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Qualitative evaluation of the flow supplied by personalized ventilation using schlieren imaging and thermography JF - Building and Environment N2 - Personalized ventilation (PV) is a mean of delivering conditioned outdoor air into the breathing zone of the occupants. This study aims to qualitatively investigate the personalized flows using two methods of visualization: (1) schlieren imaging using a large schlieren mirror and (2) thermography using an infrared camera. While the schlieren imaging was used to render the velocity and mass transport of the supplied flow, thermography was implemented to visualize the air temperature distribution induced by the PV. Both studies were conducted using a thermal manikin to simulate an occupant facing a PV outlet. As a reference, the flow supplied by an axial fan and a cased axial fan was visualized with the schlieren system as well and compared to the flow supplied by PV. Schlieren visualization results indicate that the steady, low-turbulence flow supplied by PV was able to penetrate the thermal convective boundary layer encasing the manikin's body, providing clean air for inhalation. Contrarily, the axial fan diffused the supplied air over a large target area with high turbulence intensity; it only disturbed the convective boundary layer rather than destroying it. The cased fan supplied a flow with a reduced target area which allowed supplying more air into the breathing zone compared to the fan. The results of thermography visualization showed that the supplied cool air from PV penetrated the corona-shaped thermal boundary layer. Furthermore, the supplied air cooled the surface temperature of the face, which indicates the large impact of PV on local thermal sensation and comfort. KW - Bildverarbeitung KW - Photothermische Methode KW - Visualisierung KW - Belüftung KW - Lüftungsanlage KW - Schlieren imaging KW - Thermography KW - Visualization KW - Personalized ventilation KW - Axial fan Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20211008-45117 UR - https://www.sciencedirect.com/science/article/abs/pii/S0360132319306602?via%3Dihub N1 - This is the accepted manuscript of the article published by Elsevier in Building and Environment 167 (2020) 106450, which can be found at https://doi.org/10.1016/j.buildenv.2019.106450. VL - 2020 IS - Volume 167, article 106450 PB - Elsevier CY - New York ER - TY - CHAP A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Measuring and visualizing the flow supplied by personalized ventilation T2 - Proceedings Book Roomvent 2020 N2 - This study investigates the flow supplied by personalized ventilation (PV) by means of anemometer measurements and schlieren visualization. The study was conducted using a thermal manikin to simulate a seated occupant facing a PV outlet. Air velocity was measured at multiple points in the flow field; the collected velocity values were used to calculate the turbulence intensity. Results indicated that PV was supplying air with low turbulence intensity that was able to penetrate the convective boundary layer of the manikin to supply clean air for inhalation. The convective boundary layer, however, obstructed the supplied flow and reduced its velocity by a total of 0.26 m/s. The PV flow preserved its value until about 10 cm from the face where velocity started to drop. Further investigations were conducted to test a PV diffuser with a relatively large outlet diameter (18 cm). This diffuser was developed using 3d-modelling and 3d-printing. The diffuser successfully distributed the flow over the larger outlet area. However, the supplied velocity and turbulence fields were not uniform across the section. KW - Belüftung KW - Luftqualität KW - Personalized ventilation KW - Schlieren imaging KW - Air quality KW - Thermal manikin Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20220622-46573 CY - Turin, Italy ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Der Kühlungseffekt der personalisierten Lüftung T1 - The cooling effect of personalized ventilation systems JF - Bauphysik N2 - Personalisierte Lüftung (PL) kann die thermische Behaglichkeit sowie die Qualität der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugeführt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierfür wurden zwei Ansätze zur Bewertung des Kühlungseffekts der PL untersucht: basierend auf (1) der äquivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchführung der Simulationen wurde das numerische Modell zunächst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des Kühlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser berücksichtigt werden. N2 - Personalized ventilation (PV) can improve thermal comfort and inhaled air quality by supplying air to each workstation separately. This study investigates the impact of PV on the thermal state of the users under summer boundary conditions. Two approaches to evaluating the cooling effect of PV were investigated, based on equivalent temperature and based on thermal sensation. Both approaches implemented measured and simulated values of the cooling effect of PV. Before conducting the simulations, the numerical model was first validated against measured data collected in a climate chamber equipped with a thermal manikin. Results indicated that the thermal sensation approach can be more suitable for evaluating the cooling effect of PV due to the complex physiological factors it considers. KW - Lüftung KW - Strömung KW - Raumklima KW - Temperatur KW - personalized ventilation KW - computational fluid dynamics KW - Simulation KW - personalisierte Lüftung KW - äquivalente Temperatur KW - thermisches Empfinden Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20201020-42723 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/bapi.202000018 N1 - © 2020 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin. Dieser Artikel kann für den persönlichen Gebrauch heruntergeladen werden. Andere Verwendungen bedürfen der vorherigen Zustimmung der Autoren und des Verlags Ernst & Sohn. Der folgende Artikel erschien in der Bauphysik 42 (2020), Heft 5, 218-225, DOI: 10.1002/bapi.202000018 VL - 2020 IS - volume 42, issue 5 SP - 218 EP - 225 PB - Ernst & Sohn bei John Wiley & Sons CY - Hoboken ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations JF - Indoor Air N2 - The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant. KW - Behaglichkeit KW - Raumklima KW - Strömungsmechanik KW - Fluid KW - computational fluid dynamics KW - desk fan KW - ductless personalized ventilation KW - IAQ KW - thermal comfort Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200422-41407 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12672 VL - 2020 PB - John Wiley & Sons Ltd ER - TY - JOUR A1 - Alsaad, Hayder A1 - Völker, Conrad T1 - Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation? JF - Indoor Air N2 - This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off. KW - Strömungsmechanik KW - Kontamination KW - Belüftung KW - Luftqualität KW - computational fluid dynamics KW - cross-contamination KW - ductless personalized ventilation KW - indoor air quality KW - tracer gas Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20200805-42072 UR - https://onlinelibrary.wiley.com/doi/full/10.1111/ina.12720 VL - 2020 PB - John Wiley & Sons Ltd ER -