TY - JOUR A1 - Schuch, Kai T1 - Theoretische Grundlagen zum Aggregationsprozess von Wassergläsern im Hinblick auf silikatische Beschichtungen JF - Steuerung des Aggregationsprozesses in wässrigen Alkalisilikatsolen durch spezielle Gelinitiatoren und moderate Wärmebehandlung zum Aufbau einer stabilen Silikatbeschichtung N2 - Der Artikel beinhaltet den theoretischen Teil und die Ergebnisse der Dissertation von Kai Schuch, Bauhaus Universität Weimar, Nov. 2014 KW - Alkalisilikatsol KW - Wasserglas KW - Silicate KW - Gel KW - Aggregationsprozess KW - Wasserglas KW - Gelbildung KW - Alkalisilikat KW - Silikat Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20160113-24971 ER - TY - JOUR A1 - Lahmer, Tom A1 - Nguyen-Tuan, Long A1 - Könke, Carsten A1 - Bettzieche, Volker T1 - Thermo-hydro-mechanische 3-D-Simulation von Staumauern‐Modellierung und Validierung JF - WASSERWIRTSCHAFT N2 - Thermo-hydro-mechanische 3-D-Simulation von Staumauern‐Modellierung und Validierung KW - Angewandte Mathematik KW - Stochastik KW - Strukturmechanik Y1 - 2016 SP - 27 EP - 30 ER - TY - JOUR A1 - Nanthakumar, S.S. A1 - Lahmer, Tom A1 - Zhuang, Xiaoying A1 - Park, Harold S. A1 - Rabczuk, Timon T1 - Topology optimization of piezoelectric nanostructures JF - Journal of the Mechanics and Physics of Solids N2 - Topology optimization of piezoelectric nanostructures KW - Angewandte Mathematik KW - Stochastik KW - Strukturmechanik Y1 - 2016 SP - 316 EP - 335 ER - TY - JOUR A1 - Bourikas, Leonidas A1 - James, Patrick A. B. A1 - Bahaj, AbuBakr S. A1 - Jentsch, Mark F. A1 - Shen, Tianfeng A1 - Chow, David H. C. A1 - Darkwa, Jo T1 - Transforming typical hourly simulation weather data files to represent urban locations by using a 3D urban unit representation with micro-climate simulations JF - Future Cities and Environment N2 - Urban and building energy simulation models are usually driven by typical meteorological year (TMY) weather data often in a TMY2 or EPW format. However, the locations where these historical datasets were collected (usually airports) generally do not represent the local, site specific micro-climates that cities develop. In this paper, a humid sub-tropical climate context has been considered. An idealised “urban unit model” of 250 m radius is being presented as a method of adapting commonly available weather data files to the local micro-climate. This idealised “urban unit model” is based on the main thermal and morphological characteristics of nine sites with residential/institutional (university) use in Hangzhou, China. The area of the urban unit was determined by the region of influence on the air temperature signal at the centre of the unit. Air temperature and relative humidity were monitored and the characteristics of the surroundings assessed (eg green-space, blue-space, built form). The “urban unit model” was then implemented into micro-climatic simulations using a Computational Fluid Dynamics – Surface Energy Balance analysis tool (ENVI-met, Version 4). The “urban unit model” approach used here in the simulations delivered results with performance evaluation indices comparable to previously published work (for air temperature; RMSE <1, index of agreement d > 0.9). The micro-climatic simulation results were then used to adapt the air temperature and relative humidity of the TMY file for Hangzhou to represent the local, site specific morphology under three different weather forcing cases, (ie cloudy/rainy weather (Group 1), clear sky, average weather conditions (Group 2) and clear sky, hot weather (Group 3)). Following model validation, two scenarios (domestic and non-domestic building use) were developed to assess building heating and cooling loads against the business as usual case of using typical meteorological year data files. The final “urban weather projections” obtained from the simulations with the “urban unit model” were used to compare the degree days amongst the reference TMY file, the TMY file with a bulk UHI offset and the TMY file adapted for the site-specific micro-climate (TMY-UWP). The comparison shows that Heating Degree Days (HDD) of the TMY file (1598 days) decreased by 6 % in the “TMY + UHI” case and 13 % in the “TMY-UWP” case showing that the local specific micro-climate is attributed with an additional 7 % (ie from 6 to 13 %) reduction in relation to the bulk UHI effect in the city. The Cooling Degree Days (CDD) from the “TMY + UHI” file are 17 % more than the reference TMY (207 days) and the use of the “TMY-UWP” file results to an additional 14 % increase in comparison with the “TMY + UHI” file (ie from 17 to 31 %). This difference between the TMY-UWP and the TMY + UHI files is a reflection of the thermal characteristics of the specific urban morphology of the studied sites compared to the wider city. A dynamic thermal simulation tool (TRNSYS) was used to calculate the heating and cooling load demand change in a domestic and a non-domestic building scenario. The heating and cooling loads calculated with the adapted TMY-UWP file show that in both scenarios there is an increase by approximately 20 % of the cooling load and a 20 % decrease of the heating load. If typical COP values for a reversible air-conditioning system are 2.0 for heating and 3.5 for cooling then the total electricity consumption estimated with the use of the “urbanised” TMY-UWP file will be decreased by 11 % in comparison with the “business as usual” (ie reference TMY) case. Overall, it was found that the proposed method is appropriate for urban and building energy performance simulations in humid sub-tropical climate cities such as Hangzhou, addressing some of the shortfalls of current simulation weather data sets such as the TMY. KW - Mikroklima KW - Simulation KW - Stadt KW - Wetter KW - Idealised urban unit model, Micro-climate simulations, Urban weather projections, Cities Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170418-31348 UR - http://link.springer.com/article/10.1186/s40984-016-0020-4 ER - TY - JOUR A1 - Meel, Inder P. A1 - Satirasetthavee, Dussadee A1 - Kanitpong, Kunnawee A1 - Taneerananon, Pichai T1 - Using Czech TCT to Assess Safety Impact of Deceleration Lane at Thai U-turns JF - ENGINEERING JOURNAL-THAILAND N2 - Purpose of this study is to evaluate safety impact of the deceleration lane at the Upstream Zone of at-grade U-turns on 4-lane divided Thai highways. A substantial speed reduction is required by vehicles for diverging and making U-turn, and the deceleration lanes are provided for this purpose. These lanes are also providing a storage space for the U-turning vehicles to avoid unnecessary blockage of through lanes and reduce the potential of rear-end collisions. The safety at the U-turn is greatly influenced by the proper or improper use of the deceleration lanes. Subject to their length, full or partial speed adjustment can occur within the deceleration lane also the road users’ behavior is influenced. To assess the safety impact, the four groups of U-turns with the varying length of deceleration lanes were identified. Owing to limitation of availability and reliability of road crash data in Thailand, widely accepted Traffic Conflict Technique (TCT) was used as an alternative and proactive methodology. The U-turns’ geometric data, traffic conflicts and volume data were recorded in the field at 8 locations, 8 hours per location. Severity Conflict Rate (SCR) was assessed by applying a weighing factor (based on the severity grades according to the Czech TCT) to the observed conflicts related to the conflicting traffic volumes. A comparative higher value of SCR represents a lower level of safety. According to the results, increase in the functional length of the deceleration lane yields a lower value of SCR and a higher level of the road safety. KW - Verkehrssicherheit KW - Highway Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:gbv:wim2-20170406-31097 SP - 121 EP - 135 ER -