@article{JentschKulleBodeetal., author = {Jentsch, Mark F. and Kulle, Christoph and Bode, Tobias and Pauer, Toni and Osburg, Andrea and Namgyel, Karma and Euthra, Karma and Dukjey, Jamyang and Tenzin, Karma}, title = {Field study of the building physics properties of common building types in the Inner Himalayan valleys of Bhutan}, series = {Energy for Sustainable Development 38}, journal = {Energy for Sustainable Development 38}, doi = {10.25643/bauhaus-universitaet.3139}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20170419-31393}, pages = {48 -- 66}, abstract = {Traditionally, buildings in the Inner Himalayan valleys of Bhutan were constructed from rammed earth in the western regions and quarry stone in the central and eastern regions. Whilst basic architectural design elements have been retained, the construction methods have however changed over recent decades alongside expectations for indoor thermal comfort. Nevertheless, despite the need for space heating, thermal building performance remains largely unknown. Furthermore, no dedicated climate data is available for building performance assessments. This paper establishes such climatological information for the capital Thimphu and presents an investigation of building physics properties of traditional and contemporary building types. In a one month field study 10 buildings were surveyed, looking at building air tightness, indoor climate, wall U-values and water absorption of typical wall construction materials. The findings highlight comparably high wall U-values of 1.0 to 1.5 W/m²K for both current and historic constructions. Furthermore, air tightness tests show that, due to poorly sealed joints between construction elements, windows and doors, many buildings have high infiltration rates, reaching up to 5 air changes per hour. However, the results also indicate an indoor climate moderating effect of more traditional earth construction techniques. Based on these survey findings basic improvements are being suggested.}, subject = {Luftdichtheit}, language = {en} } @article{AlsaadVoelker, author = {Alsaad, Hayder and V{\"o}lker, Conrad}, title = {Der K{\"u}hlungseffekt der personalisierten L{\"u}ftung}, series = {Bauphysik}, volume = {2020}, journal = {Bauphysik}, number = {volume 42, issue 5}, publisher = {Ernst \& Sohn bei John Wiley \& Sons}, address = {Hoboken}, doi = {10.25643/bauhaus-universitaet.4272}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20201020-42723}, pages = {218 -- 225}, abstract = {Personalisierte L{\"u}ftung (PL) kann die thermische Behaglichkeit sowie die Qualit{\"a}t der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugef{\"u}hrt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierf{\"u}r wurden zwei Ans{\"a}tze zur Bewertung des K{\"u}hlungseffekts der PL untersucht: basierend auf (1) der {\"a}quivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchf{\"u}hrung der Simulationen wurde das numerische Modell zun{\"a}chst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des K{\"u}hlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser ber{\"u}cksichtigt werden.}, subject = {L{\"u}ftung}, language = {de} }