@inproceedings{MuellerLudwig, author = {M{\"u}ller, Matthias and Ludwig, Horst-Michael}, title = {Sulfatangriff magnesiumhaltiger W{\"a}sser auf M{\"o}rtel unterschiedlicher Zusammensetzung}, series = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, booktitle = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, editor = {Ludwig, Horst-Michael}, organization = {F.A.Finger-Institut f{\"u}r Baustoffkunde, Bauhaus-Universit{\"a}t Weimar}, isbn = {978-3-00-034075-8 (Bauhaus-Universit{\"a}tsverlag Weimar)}, doi = {10.25643/bauhaus-universitaet.4873}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20240507-48732}, pages = {489-496}, abstract = {Die besondere Aggressivit{\"a}t von hochkonzentrierten Magnesiumsulfatl{\"o}sungen bei Einwirkung auf Beton ist seit vielen Jahrzehnten bekannt. Neben dem Sulfat greift zus{\"a}tzlich auch das Magnesium den Zementstein an. Bei hohen L{\"o}sungskonzentrationen nimmt der Magnesiumangriff gegen{\"u}ber dem Sulfatangriff sogar eine dominante Rolle ein. Magnesiumgehalte unter 300 mg/l im Grundwasser gelten allerdings bislang als nicht angreifend. In Auslagerungs- und Laborversuchen wurde jedoch festgestellt, dass auch bei praxisrelevanten Magnesium- (<300 mg/l) und Sulfatgehalten (1.500 mg/l) das Magnesium zu einer deutlichen Versch{\"a}rfung des Sulfatangriffes bei niedrigen Temperaturen f{\"u}hrte. Diese Versch{\"a}rfung trat bei M{\"o}rteln und Betonen auf, bei denen der erh{\"o}hte Sulfatwiderstand durch einen teilweisen Zementersatz mit 20 \% Flugasche zu einem CEM II/A-LL erreicht werden sollte, gem{\"a}ß der Flugascheregelung nach EN 206-1/DIN 1045-2. Bei einem teilweisen Zementersatz durch 30 \% Flugasche konnte auch in magnesiumhaltigen Sulfatl{\"o}sungen eine deutliche Verbesserung des Sulfatwiderstandes erreicht werden. M{\"o}rtel mit HS-Zement als Bindemittel wiesen keinerlei Sch{\"a}den auf. Schadensverursachend war eine Kombination mehrerer Einfl{\"u}sse. Zum einen wurde der Sulfatwiderstand des Zement-Flugasche-Systems durch die unzureichende Reaktion der Flugasche infolge der niedrigen Lagerungstemperatur geschw{\"a}cht. Zum anderen konnte durch die Einwirkung des Magnesiums in der Randzone vermutlich eine Destabilisierung der C-S-H-Phasen erfolgen, wodurch die Thaumasitbildung an dieser Stelle forciert wurde. Zus{\"a}tzlich wurde durch den Portlanditverbrauch und die pH-Wert-Absenkung in der Randzone die puzzolanische Reaktion der Flugasche behindert.}, subject = {Beton}, language = {de} } @inproceedings{MuellerEhrhardtLudwig, author = {M{\"u}ller, Matthias and Ehrhardt, Dirk and Ludwig, Horst-Michael}, title = {Optimierung der Nachbehandlung von Waschbetonoberfl{\"a}chen}, series = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, booktitle = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, editor = {Ludwig, Horst-Michael}, organization = {F.A.Finger-Institut f{\"u}r Baustoffkunde, Bauhaus-Universit{\"a}t Weimar}, isbn = {978-3-00-034075-8}, doi = {10.25643/bauhaus-universitaet.4872}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20240226-48722}, pages = {794-781}, abstract = {Der Nachbehandlung eines Fahrbahndeckenbetons kommt zum Erzielen eines hohen Frost-Tausalz-Widerstandes der fertigen Betondecke eine besondere Bedeutung zu. Bei der Waschbetonbauweise erfolgt die Nachbehandlung in mehreren Schritten. Eine erste Nachbehandlung gew{\"a}hrleistet den Verdunstungsschutz des Betons bis zum Zeitpunkt des Ausb{\"u}rstens des verz{\"o}gerten Oberfl{\"a}chenm{\"o}rtels. Daran schließt sich die zweite Nachbehandlung an, in der Regel durch Aufspr{\"u}hen eines fl{\"u}ssigen Nachbehandlungsmittels. Der zweite Nachbehandlungsschritt ist entscheidend f{\"u}r den Frost-Tausalz-Widerstand der Betondecke. Im Rahmen eines Forschungsprojektes wurde daher untersucht, inwiefern durch eine Optimierung der zweiten Nachbehandlung der Frost-Tausalz-Widerstand von Waschbetonoberfl{\"a}chen erh{\"o}ht werden kann, insbesondere bei Verwendung h{\"u}ttensandhaltiger Zemente. Schon durch eine einmalige Nassnachbehandlung wurde eine deutlich h{\"o}herer Widerstand der Waschbetons gegen Frost-Tausalz-Angriff erzielt.}, subject = {Beton}, language = {de} } @phdthesis{PhungThi, author = {Phung Thi, Thu Ha}, title = {Metakaolin as an Additive in Composite Cement}, publisher = {F. A. Finger-Institut f{\"u}r Baustoffkunde}, address = {Weimar}, isbn = {978-3-00-042655-1}, doi = {10.25643/bauhaus-universitaet.1976}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20130705-19764}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {119}, abstract = {Metakaolin made from kaolin is used around the world but rarely in Vietnam where abundant deposits of kaolin is found. The first studies of producing metakaolin were conducted with high quality Vietnamese kaolins. The results showed the potential to produce metakaolin, and its effect has on strength development of mortars and concretes. However, utilisation of a low quality kaolin for producing Vietnamese metakaolin has not been studied so far. The objectives of this study were to produce a good quality metakaolin made from low quality Vietnamese kaolin and to facilitate the utilisation of Vietnamese metakaolin in composite cements. In order to reach such goals, the optimal thermal conversion of Vietnamese kaolin into metakaolin was carried out by many investigations, and as such the optimal conversion is found using the analysis results of DSC/TGA, XRD and CSI. During the calcination in a range of 500 - 800 oC lasting for 1 - 5 hours, the characterisation of calcinated kaolin was also monitored for mass loss, BET surface, PSD, density as well as the presence of the residual water. It is found to have a well correlation between residual water and BET surface. The pozzolanic activity of metakaolin was tested by various methods regarding to the saturated lime method, mCh and TGA-CaO method. The results of the study showed which method is the most suitable one to characterise the real activity of metakaolin and can reach the greatest agreement with concrete performance. Furthermore, the pozzolanic activity results tested using methods were also analysed and compared to each other with respect to the BET surface. The properties of Vietnam metakaolin was established using investigations on water demand, setting time, spread-flowability, and strength. It is concluded that depending on the intended use of composite cement and weather conditions of cure, each Vietnamese metakaolin can be used appropriately to produce (1) a composite cement with a low water demand (2) a high strength of composite cement (3) a composite cement that aims to reduce CO2 emissions and to improve economics of cement products (4) a high performance mortar. The durability of metakaolin mortar was tested to find the needed metakaolin content against ASR, sulfat and sulfuric acid attacks successfully.}, subject = {metakaolin}, language = {en} } @phdthesis{Wieteska, author = {Wieteska, Marcin}, title = {Untersuchungen zur Optimierung des Feuerwiderstandsverhaltens von Gipsplatten}, publisher = {Marcin Wieteska}, address = {Warszawa}, isbn = {978-83-936473-0-9}, doi = {10.25643/bauhaus-universitaet.1782}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20121207-17829}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {176}, abstract = {Die Qualit{\"a}t von Beplankungselementen wirkt sich deutlich auf den Feuerwiderstand von Metallst{\"a}nder-Wandkonstruktionen aus. Daher wurde im Rahmen dieser Arbeit der Einfluss von Zus{\"a}tzen in Gipsplatten bez{\"u}glich einer m{\"o}glichen Verbesserung dieser Eigenschaft untersucht. Zu diesem Zweck wurden spezielle, den jeweiligen Untersuchungsbedingungen angepasste Probek{\"o}rper unter Verwendung verschiedenster Zus{\"a}tze gefertigt. Die Beurteilung deren Auswirkungen erfolgte insbesondere mittels nachfolgender f{\"u}nf Kriterien: 1) dem Zeitpunkt der Temperaturerh{\"o}hung nach der Probek{\"o}rperentw{\"a}sserung, 2) dem Maximalwert der Plattenr{\"u}ckseitentemperatur, 3) der Gr{\"o}ße und der Anzahl der Risse, 4) der Plattenstabilit{\"a}t nach der W{\"a}rmebeanspruchung, 5) der Verk{\"u}rzung von prismatischen Probek{\"o}rpern. Besonders wichtig war hierbei die Charakterisierung der Auswirkungen einer simulierten Brandbeanspruchung von 970 °C {\"u}ber 90 Minuten auf Labor-Gipsplatten. Dabei wurde die Temperatur{\"a}nderung auf der Plattenr{\"u}ckseite {\"u}ber den gesamten Pr{\"u}fzeitraum kontinuierlich erfasst. Die Bewertung des Zusammenhalts der Platten nach der thermischen Beanspruchung erfolgte erstmals quantitativ {\"u}ber Anzahl und Gr{\"o}ße der an den Proben entstandenen Risse. Urs{\"a}chlich f{\"u}r die Rissbildung ist die Verringerung des Probek{\"o}rpervolumens infolge des ausgetriebenen Kristallwassers. Da dieser Parameter im Plattenversuch nicht bestimmt werden kann, wurde erg{\"a}nzend das L{\"a}ngen{\"a}nderungsverhalten von Prismen im Ergebnis einer 90min{\"u}tigen Temperung bei 1000 °C im Muffelofen ermittelt. Besonders vorteilhaft hat sich die Zugabe von 80 g/m2 Glasfasern und 7,75 \% Kalksteinmehl auf das Verhalten von Gipsplatten bei Brandbeanspruchung ausgewirkt. Diese Verbesserung ist insbesondere auf h{\"o}here Stabilit{\"a}t und geringere Schrumpfung der Gipsplatte zur{\"u}ckzuf{\"u}hren. Basierend auf den im Labormaßstab erhaltenen Ergebnissen wurden Rezepturvorschl{\"a}ge zur Verbesserung des Feuerwiderstandsverhaltens von Gipsplatten unter Praxisbedingungen entwickelt. Die Herstellung der erforderlichen großformatigen Platten erfolgte auf der Bandstraße der Knauf Gips KG. Diese Platten wurden als Wandkonstruktion mit zweilagiger Beplankung einer großtechnischen Pr{\"u}fung erfolgreich unterzogen. Eine geringere Durchbiegung der Wandkonstruktion, eine verminderte Volumenreduzierung der Platten sowie eine erh{\"o}hte Plattenstabilit{\"a}t belegen die verbesserten Eigenschaften dieser modifizierten Feuerschutzplatte. Weitere durchgef{\"u}hrte Untersuchungen ergaben, dass es unerheblich ist, ob die Platten auf Basis von Natur- oder REA-Gips bzw. mit hohem oder niedrigem Fl{\"a}chengewicht gefertigt wurden. Das eindeutig beste Ergebnis mit einer Feuerwiderstandsdauer von 118 Minuten hat eine Wandkonstruktion aus Feuerschutzplatten auf Basis eines Stuckgipses aus 100 \% REA-Gips mit einem Anteil von 83,9 g/m2 Glasfasern und 1 \% Vermiculit und einem Fl{\"a}chengewicht von 10,77 kg/m2, bei einer Plattenst{\"a}rke von 12,5 mm. Die als Ziel vorgebende Feuerwiderstandsdauer von 120 Minuten bei zweilagiger Beplankung ohne D{\"a}mmstoff k{\"o}nnte k{\"u}nftig erreicht werden, wenn es gelingt, die Volumenreduzierung noch besser zu kompensieren und die Plattenstabilit{\"a}t zu steigern. Eine M{\"o}glichkeit hierzu ist die Substitution der beidseitigen Kartonlagen durch eine Glasfaser-Vliesummantelung. Die Wandkonstruktion W112 ohne D{\"a}mmstoff erreicht dabei eine Feuerwiderstandsdauer von weit {\"u}ber 120 Minuten, wobei der Gipskern mit Glasfasern armiert ist.}, subject = {0947}, language = {de} }