@article{VoelkerMaempelKornadt, author = {V{\"o}lker, Conrad and M{\"a}mpel, Silvio and Kornadt, Oliver}, title = {Measuring the human body's micro-climate using a thermal manikin}, series = {Indoor Air}, journal = {Indoor Air}, number = {24, 6}, doi = {10.25643/bauhaus-universitaet.3815}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20181025-38153}, pages = {567 -- 579}, abstract = {The human body is surrounded by a micro-climate which results from its convective release of heat. In this study, the air temperature and flow velocity of this micro-climate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the micro-climate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the micro-climate shape strongly depends not only on the body segment, but also on boundary conditions: the higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the air flow in the micro-climate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient.}, subject = {Raumklima}, language = {en} } @article{VoelkerKornadtOstry, author = {V{\"o}lker, Conrad and Kornadt, Oliver and Ostry, Milan}, title = {Temperature reduction due to the application of phase change materials}, series = {Energy and Buildings}, journal = {Energy and Buildings}, number = {40, 5}, doi = {10.25643/bauhaus-universitaet.3816}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20181025-38166}, pages = {937 -- 944}, abstract = {Overheating is a major problem in many modern buildings due to the utilization of lightweight constructions with low heat storing capacity. A possible answer to this problem is the emplacement of phase change materials (PCM), thereby increasing the thermal mass of a building. These materials change their state of aggregation within a defined temperature range. Useful PCM for buildings show a phase transition from solid to liquid and vice versa. The thermal mass of the materials is increased by the latent heat. A modified gypsum plaster and a salt mixture were chosen as two materials for the study of their impact on room temperature reduction. For realistic investigations, test rooms were erected where measurements were carried out under different conditions such as temporary air change, alternate internal heat gains or clouding. The experimental data was finally reproduced by dint of a mathematical model.}, subject = {Raumklima}, language = {en} } @article{VoelkerBeckmannKoehlmannetal., author = {V{\"o}lker, Conrad and Beckmann, Julia and Koehlmann, Sandra and Kornadt, Oliver}, title = {Occupant requirements in residential buildings - an empirical study and a theoretical model}, series = {Advances in Building Energy Research}, journal = {Advances in Building Energy Research}, number = {7 (1)}, doi = {10.25643/bauhaus-universitaet.3813}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20181015-38137}, pages = {35 -- 50}, abstract = {Occupant needs with regard to residential buildings are not well known due to a lack of representative scientific studies. To improve the lack of data, a large scale study was carried out using a Post Occupancy Evaluation of 1,416 building occupants. Several criteria describing the needs of occupants were evaluated with regard to their subjective level of relevance. Additionally, we investigated the degree to which deficiencies subjectively exist, and the degree to which occupants were able to accept them. From the data obtained, a hierarchy of criteria was created. It was found that building occupants ranked the physiological needs of air quality and thermal comfort the highest. Health hazards such as mould and contaminated building materials were unacceptable for occupants, while other deficiencies were more likely to be tolerated. Occupant satisfaction was also investigated. We found that most occupants can be classified as satisfied, although some differences do exist between different populations. To explain the relationship between the constructs of what we call relevance, acceptance, deficiency and satisfaction, we then created an explanatory model. Using correlation and regression analysis, the validity of the model was then confirmed by applying the collected data. The results of the study are both relevant in shaping further research and in providing guidance on how to maximize tenant satisfaction in real estate management.}, subject = {Post Occupancy Evaluation}, language = {en} } @article{VoelkerAlsaad, author = {V{\"o}lker, Conrad and Alsaad, Hayder}, title = {Simulating the human body's microclimate using automatic coupling of CFD and an advanced thermoregulation model}, series = {Indoor Air}, volume = {2018}, journal = {Indoor Air}, number = {28, Heft 3}, doi = {10.25643/bauhaus-universitaet.3851}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20190218-38517}, pages = {415 -- 425}, abstract = {This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of the human body back and forth between the CFD solver and the UCB model until reaching convergence defined by a stopping criterion. The location from which data are transferred to the UCB model was determined using a new approach based on the temperature difference between subsequent points on the temperature profile curve in the vicinity of the body surface. This approach was used because the microclimate surrounding the human body differs in thickness depending on the body segment and the surrounding environment. To accurately simulate the thermal environment, the numerical model was validated beforehand using experimental data collected in a climate chamber equipped with a thermal manikin. Furthermore, an example of the practical implementations of this coupling is reported in this paper through radiant floor cooling simulation cases, in which overall and local thermal sensation and comfort were investigated using the coupled UCB model.}, subject = {Numerische Str{\"o}mungssimulation}, language = {en} } @misc{Voelker2005, type = {Master Thesis}, author = {V{\"o}lker, Conrad}, title = {Untersuchungen hinsichtlich des Einflusses von PCM auf die Raumlufttemperatur}, doi = {10.25643/bauhaus-universitaet.663}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20111215-6639}, school = {Bauhaus-Universit{\"a}t Weimar}, year = {2005}, abstract = {Das Ziel der vorliegenden Diplomarbeit war es, „Untersuchungen hinsichtlich des Einflusses von Phase Change Materials auf die Raumlufttemperatur" durchzuf{\"u}hren und anschließend die Ergebnisse auszuwerten. Dabei galt es, thermodynamische Grundlagen zu erl{\"a}utern sowie den derzeitigen Stand der Forschung darzulegen. Dies wurde umfassend bearbeitet, allerdings kann hierbei aufgrund des Umfangs und der Vielfalt im Bereich der internationalen PCM-Forschung kein Anspruch auf Vollst{\"a}ndigkeit erhoben werden. Ein Hauptteil dieser Arbeit bestand darin, den Versuchsaufbau der Referenzr{\"a}ume im Eiermann-Bau in Apolda als Grundlage f{\"u}r sp{\"a}tere Messungen detailliert zu beschreiben. Dabei wurde auf die gesamte Messanlage, die eingebrachten PCM sowie auf daraus resultierende physikalische Kenngr{\"o}ßen ausf{\"u}hrlich eingegangen. Es galt, geometrische, chemische und physikalische Einfl{\"u}sse einzusch{\"a}tzen, aber auch Schwachstellen aufzudecken, um die sp{\"a}ter folgenden Messreihen exakt auswerten zu k{\"o}nnen. Als kritisch einzusch{\"a}tzende Gr{\"o}ße fiel dabei besonders das eingebrachte Salzgemisch auf, welches hinsichtlich des Schmelz- und Kristallisationsbereiches als kaum beurteilbar auffiel. Dies konnte auch nach mehreren Untersuchungen, hier ist insbesondere die dynamische Differenzkalorimetrie zu nennen, nicht hinreichend gekl{\"a}rt werden. Basierend auf diesen Erkenntnissen wurden vergleichende Messreihen durchgef{\"u}hrt, welche durch verschiedene Luftwechselraten gestaltet wurden. Im Maximum konnte dabei im PCM-konditionierten Raum eine Reduktion der Temperatur um 6 K erreicht werden. Dabei muss allerdings ber{\"u}cksichtigt werden, dass diese Differenz gr{\"o}ßtenteils auf die thermische Masse des Salzgemischs zur{\"u}ckgef{\"u}hrt werden kann. Eine abschließende Messung ohne Salzgemisch zeigte, dass aufgrund des latenten W{\"a}rmespeicherverm{\"o}gens des PCM-Putzes lediglich eine thermische Differenz von 2 K erreicht werden kann. Hinsichtlich der Luftwechselrate ist anzumerken, dass die erwartete, vergleichsweise z{\"u}gige Ausk{\"u}hlung trotz L{\"u}ftung in der Praxis nicht nachvollzogen werden konnte. Zur Auswertung der gewonnenen Messwerte galt es, das am Lehrstuhl Bauphysik vorhandene mathematische Minimalmodell auf die am Objekt vorhandenen Randbedingungen anzupassen. Aus den Datenwolken der Atmosph{\"a}rentemperatur sowie der Globalstrahlung mussten Funktionen approximiert werden, da diese {\"a}ußeren Zw{\"a}nge einen entscheidenden Einfluss auf den Verlauf der Innenraumtemperatur aus{\"u}ben. Die Ergebnisse der Berechungen des Temperaturverlaufs k{\"o}nnen als zufrieden stellend betrachtet werden, jedoch wurde deutlich, dass ein genaues Nachstellen nicht m{\"o}glich ist. Dies ist vor allem auf die Tatsache zur{\"u}ckzuf{\"u}hren, dass das Minimalmodell lediglich eine Beschreibung der wesentlichen Prozesse mathematisch abbildet. Eine kritische Auseinandersetzung hinsichtlich allgemeiner Standpunkte als auch der Anwendbarkeit auf die Referenzr{\"a}ume wurde abschließend diskutiert.}, subject = {Latentw{\"a}rmespeicher}, language = {de} } @unpublished{VogelVoelkerBodeetal., author = {Vogel, Albert and V{\"o}lker, Conrad and Bode, Matthias and Marx, Steffen}, title = {Messung und Simulation der Erw{\"a}rmung von erm{\"u}dungsbeanspruchten Betonprobek{\"o}rpern}, series = {Bauphysik}, volume = {2020}, journal = {Bauphysik}, number = {Volume 42, Issue 2}, publisher = {John Wiley and Sons}, doi = {10.25643/bauhaus-universitaet.4147}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20200425-41471}, pages = {86 -- 93}, abstract = {Im vorliegenden Beitrag werden Messungen und Berechnungen vorgestellt, die die Temperaturentwicklung in Betonzylindern aufgrund zyklischer Beanspruchung genau beschreiben. Die Messungen wurden in einem Versuchsstand, die Berechnungen im FEM-Programm ANSYS durchgef{\"u}hrt. Mit Hilfe der Temperaturmessungen konnten die Simulationen f{\"u}r die Temperaturentwicklung der Betonzylinder mit der verwendeten Betonrezeptur validiert werden. Die Untersuchungen lassen den Schluss zu, dass bei zyklischer Probek{\"o}rperbelastung und der einhergehenden Probek{\"o}rperdehnung Energie dissipiert wird und diese maßgeblich f{\"u}r die Erw{\"a}rmung der Probe verantwortlich ist.}, subject = {zyklische Beanspruchung}, language = {de} } @techreport{VogelVoelkerArnoldetal., author = {Vogel, Albert and V{\"o}lker, Conrad and Arnold, J{\"o}rg and Schmidt, Jens and Thurow, Torsten and Braunes, J{\"o}rg and Tonn, Christian and Bode, Kay-Andr{\´e} and Baldy, Franziska and Erfurt, Wolfgang and Tatarin, Ren{\´e}}, title = {Methoden und Baustoffe zur nutzerorientierten Bausanierung. Schlussbericht zum InnoProfile Forschungsvorhaben}, organization = {Bauhaus-Universit{\"a}t Weimar}, isbn = {978-3-86068-501-3 (Printausg.)}, doi = {10.25643/bauhaus-universitaet.2022}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20130830-20229}, pages = {106}, abstract = {Nutzerorientierte Bausanierung bedeutet eine gegen{\"u}ber dem konventionellen Vorgehen deutlich verst{\"a}rkte Ausrichtung des Planungs- und Sanierungsprozesses auf die Anforderungen und Bed{\"u}rfnisse des zuk{\"u}nftigen Nutzers eines Geb{\"a}udes. Dies hat einerseits ein hochwertigeres Produkt zum Ergebnis, erfordert andererseits aber auch den Einsatz neuer Methoden und Baustoffe sowie ein vernetztes Zusammenarbeiten aller am Bauprozess Beteiligten. Der Fokus der Publikation liegt dabei auf den Bereichen, die eine hohe Relevanz f{\"u}r die nutzerorientierte Bausanierung aufweisen. Dabei handelt es sich insbesondere um: Computergest{\"u}tztes Bauaufmaß und digitale Bauwerksmodellierung (BIM), bauphysikalische Methoden zur Optimierung von Energieeffizienz und Behaglichkeit bei der Sanierung von Bestandsgeb{\"a}uden, zerst{\"o}rungsfreie Untersuchungsmethoden im Rahmen einer substanzschonenden Bauzustandsanalyse und Entwicklung von Erg{\"a}nzungsbaustoffen. Das Projekt nuBau ist eine Kooperation zwischen den Fakult{\"a}ten Bauingenieurwesen und Architektur der Bauhaus-Universit{\"a}t Weimar. Die beteiligten Professuren sind: Bauphysik, Informatik in der Architektur, Polymere Werkstoffe und Werkstoffe des Bauens.}, subject = {Nutzerorientierte Bausanierung}, language = {de} } @unpublished{VogelBenzVoelker, author = {Vogel, Albert and Benz, Alexander and V{\"o}lker, Conrad}, title = {Untersuchung des W{\"a}rme{\"u}bergangs von zyklisch beanspruchten Betonzylindern}, volume = {2020}, number = {Volume 42, Issue 3}, publisher = {John Wiley and Sons}, doi = {10.25643/bauhaus-universitaet.4181}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20200619-41813}, pages = {131 -- 138}, abstract = {Wiederkehrende Belastungen, wie sie beispielsweise an Br{\"u}cken oder Windenergieanlagen auftreten, k{\"o}nnen innerhalb der Nutzungsdauer solcher Bauwerke bis zu 1.000.000.000 Lastwechsel erreichen. Um das dadurch eintretende Erm{\"u}dungsverhalten von Beton zu untersuchen, werden diese zyklischen Beanspruchungen in mechanischen Versuchen mit Pr{\"u}fzylindern nachgestellt. Damit Versuche mit solch hohen Lastwechselzahlen in akzeptablen Zeitdauern durchgef{\"u}hrt werden k{\"o}nnen, wird die Belastungsfrequenz erh{\"o}ht. Als Folge dieser erh{\"o}hten Belas-tungsfrequenz erw{\"a}rmen sich allerdings die Betonprobek{\"o}rper, was zu einem fr{\"u}heren, unrealistischen Versagenszeitpunkt f{\"u}hren kann, weshalb die Erw{\"a}rmung begrenzt werden muss. Um die W{\"a}rmefreisetzung in der Probe zu untersuchen, wurden Versuche und Simulationen durchgef{\"u}hrt. Im Beitrag wird die analytische und messtechnische Analyse des W{\"a}rme{\"u}bergangs an erw{\"a}rmten Betonzylindern vorgestellt. Resultierend daraus wird eine M{\"o}glichkeit zur Reduktion der Erw{\"a}rmung an zyklisch beanspruchten Betonzylindern vorgestellt.}, subject = {Zyklische Beanspruchung}, language = {de} } @article{VogelArnoldVoelkeretal., author = {Vogel, Albert and Arnold, J{\"o}rg and Voelker, Conrad and Kornadt, Oliver}, title = {Data for sound pressure level prediction in lightweight constructions caused by structure-borne sound sources and their uncertainties}, series = {Data in Brief}, volume = {2023}, journal = {Data in Brief}, number = {Volume 48, June 2023, article 109292}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.dib.2023.109292}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20230719-64114}, pages = {1 -- 16}, abstract = {When predicting sound pressure levels induced by structure-borne sound sources and describing the sound propagation path through the building structure as exactly as possible, it is necessary to characterize the vibration behavior of the structure-borne sound sources. In this investigation, the characterization of structure-borne sound sources was performed using the two-stage method (TSM) described in EN 15657. Four different structure-borne sound sources were characterized and subsequently installed in a lightweight test stand. The resulting sound pressure levels in an adjacent receiving room were measured. In the second step, sound pressure levels were predicted according to EN 12354-5 based on the parameters of the structure-borne sound sources. Subsequently, the predicted and the measured sound pressure levels were compared to obtain reliable statements on the achievable accuracy when using source quantities determined by TSM with this prediction method.}, subject = {Bauakustik}, language = {en} } @article{TeitelbaumAlsaadAvivetal., author = {Teitelbaum, Eric and Alsaad, Hayder and Aviv, Dorit and Kim, Alexander and V{\"o}lker, Conrad and Meggers, Forrest and Pantelic, Jovan}, title = {Addressing a systematic error correcting for free and mixed convection when measuring mean radiant temperature with globe thermometers}, series = {Scientific reports}, volume = {2022}, journal = {Scientific reports}, number = {Volume 12, article 6473}, publisher = {Springer Nature}, address = {London}, doi = {10.1038/s41598-022-10172-5}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20220509-46363}, pages = {18}, abstract = {It is widely accepted that most people spend the majority of their lives indoors. Most individuals do not realize that while indoors, roughly half of heat exchange affecting their thermal comfort is in the form of thermal infrared radiation. We show that while researchers have been aware of its thermal comfort significance over the past century, systemic error has crept into the most common evaluation techniques, preventing adequate characterization of the radiant environment. Measuring and characterizing radiant heat transfer is a critical component of both building energy efficiency and occupant thermal comfort and productivity. Globe thermometers are typically used to measure mean radiant temperature (MRT), a commonly used metric for accounting for the radiant effects of an environment at a point in space. In this paper we extend previous field work to a controlled laboratory setting to (1) rigorously demonstrate that existing correction factors used in the American Society of Heating Ventilation and Air-conditioning Engineers (ASHRAE) Standard 55 or ISO7726 for using globe thermometers to quantify MRT are not sufficient; (2) develop a correction to improve the use of globe thermometers to address problems in the current standards; and (3) show that mean radiant temperature measured with ping-pong ball-sized globe thermometers is not reliable due to a stochastic convective bias. We also provide an analysis of the maximum precision of globe sensors themselves, a piece missing from the domain in contemporary literature.}, subject = {Strahlungstemperatur}, language = {en} } @masterthesis{Schuerenberg, type = {Bachelor Thesis}, author = {Sch{\"u}renberg, Philipp}, title = {Automatisierte fachliche Qualit{\"a}tssicherung in einem Crowdsourcing-basierten bauphysikalischen Lernspiel}, doi = {10.25643/bauhaus-universitaet.1673}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20120704-16734}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {53}, abstract = {In crowdsourcingbasierten Systemen kommt der Qualit{\"a}tssicherung des durch Benutzer generierten Inhaltes große Bedeutung f{\"u}r die Erhaltung der Benutzbarkeit zu. Das bauphysikalische Lehrspiel "BuildVille" benutzt f{\"u}r die Quiz-Anwendung einen Crowdsourcing-Ansatz: Die Quiz-Fragen werden von den Benutzern selbst generiert. Mit Hilfe dieser Arbeit soll sichergestellt werden, dass fehlerhafte, irrt{\"u}mlicherweise oder zum Spaß eingegebene Fragen m{\"o}glichst fr{\"u}h erkannt, korrigiert oder von der weiteren Verbreitung ausgeschlossen werden. Dazu soll mit Hilfe einer Analyse bestehender crowdsourcingbasierter Systeme bez{\"u}glich umgesetzter Qualit{\"a}tssicherungsmaßnahmen ein Konzept f{\"u}r die QS-Maßnahmen in BuildVille entwickelt werden.}, subject = {Crowdsourcing}, language = {de} } @misc{SchusterSchuster, type = {Master Thesis}, author = {Schuster, Siegbert and Schuster, Karl-Heinz}, title = {Hygrothermische Geb{\"a}udesimulation - Experimentelle Bestimmung der Randparameter und Sorptionseigenschaften von historischen R{\"a}umen}, doi = {10.25643/bauhaus-universitaet.2093}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20131219-20936}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {150}, abstract = {Forscher prognostizieren in den kommenden Jahren eine Klimaerw{\"a}rmung bis zu 6 ° C. Aus diesem Grund wurde das EU - Forschungsprojekt „ Climate for Culture" ins Leben gerufen, um Auswirkungen dieses Klimawandels auf denkmalgesch{\"u}tzte, kulturhistorische Geb{\"a}ude zu untersuchen. Ziel ist es, entsprechende Schutzmaßnahmen in konservatorischer Hinsicht zu erarbeiten. Aufgrund des Zusammenhanges zwischen Temperatur und Luftfeuchte f{\"u}hrt diese Klimaerw{\"a}rmung auch zu einer {\"A}nderung des Feuchtehaushaltes im Außenbereich und, bedingt durch einen immer vorhandenen Luftwechsel, schließlich auch im Innenbereich von Geb{\"a}uden. Die F{\"a}higkeit eines Geb{\"a}udes, durch seine Beschaffenheit auf Feuchteeinfl{\"u}sse zu reagieren, wird maßgeblich bestimmt durch seine M{\"o}glichkeit, in der Geb{\"a}udeh{\"u}lle und der vorhandenen Einrichtung anfallende Feuchte zwischenzuspeichern und diese zeitversetzt wieder an die Umgebung abzugeben. Diese F{\"a}higkeit sorptiver Fl{\"a}chen zur Feuchtepufferung konnte bislang nur mit erheblichem Aufwand ermittelt werden. In der vorliegenden Arbeit wird versucht, durch einfachere Methoden mittels hygrothermischer Simulation einen „Zweizahlwert" zu erhalten, mit dem sich diese Raumkompetenz schnell und nachvollziehbar darstellen l{\"a}sst.}, subject = {Feuchtepufferung}, language = {de} } @article{SalandinArnoldKornadt, author = {Salandin, Andrea and Arnold, J{\"o}rg and Kornadt, Oliver}, title = {Noise in an intensive care unit}, series = {The Journal of the Acoustical Society of America}, volume = {2011}, journal = {The Journal of the Acoustical Society of America}, number = {130 (6)}, doi = {10.25643/bauhaus-universitaet.3264}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20170713-32649}, pages = {3754 -- 3760}, abstract = {Patients and staff in hospitals are exposed to a complex sound environment with rather high noise levels. In intensive care units, the main noise sources are hospital staff on duty and medical equipment, which generates both operating noise and acoustic alarms. Although noise in most cases is produced during activities for the purpose of saving life, noise can induce significant changes in the depth and quality of sleep and negatively affect health in general. Results of a survey of hospital staff are presented as well as measurements in two German hospital wards: a standard two-bed room and a special Intermediate Care Unit (IMC-Unit), each in a different Intensive Care Unit (ICU). Sound pressure data were collected over a 48 hour period and converted into different levels (LAFeq, LAFmax, LAFmin, LAF 5\%), as well as a rating level LAr, which is used to take tonality and impulsiveness into account. An analysis of the survey and the measured data, together with a comparison of thresholds of national and international regulations and standards describe the acoustic situation and its likely noise effects on staff and patients.}, subject = {L{\"a}rm}, language = {en} } @misc{Rothe2005, type = {Master Thesis}, author = {Rothe, Christian}, title = {Untersuchung diffuser koh{\"a}renter Schallfelder in Atrien}, doi = {10.25643/bauhaus-universitaet.678}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20111215-6786}, school = {Bauhaus-Universit{\"a}t Weimar}, year = {2005}, abstract = {In dieser Diplomarbeit werden - anhand eines Simulationsprogrammes - die diffusen Schallfelder in Atrien untersucht. Diesbez{\"u}glich standen Referenzobjekte in Berlin zur Verf{\"u}gung. Es wurde untersucht, inwieweit sich die Raumgeometrie, die Volumina und die Absorptionseigenschaften der Umh{\"u}llungsfl{\"a}chen auf die Energieverteilung im Atriumsraum auswirken. Ziel der Arbeit ist es, Optimierungspotenziale aufzuzeigen und L{\"o}sungsvorschl{\"a}ge zu entwickeln, die zeigen, mit welchen Mitteln und Methoden die Raumakustik nachtr{\"a}glich verbessert werden kann.}, subject = {Absorption}, language = {de} } @article{PollackLueckWolfetal., author = {Pollack, Moritz and L{\"u}ck, Andrea and Wolf, Mario and Kraft, Eckhard and V{\"o}lker, Conrad}, title = {Energy and Business Synergy: Leveraging Biogenic Resources from Agriculture, Waste, and Wastewater in German Rural Areas}, series = {Sustainability}, volume = {2023}, journal = {Sustainability}, number = {volume 15, issue 24, article 16573}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/su152416573}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20231222-65172}, pages = {1 -- 25}, abstract = {The imperative to transform current energy provisions is widely acknowledged. However, scant attention has hitherto been directed toward rural municipalities and their innate resources, notably biogenic resources. In this paper, a methodological framework is developed to interconnect resources from waste, wastewater, and agricultural domains for energy utilization. This entails cataloging existing resources, delineating their potential via quantitative assessments utilizing diverse technologies, and encapsulating them in a conceptual model. The formulated models underwent iterative evaluation with engagement from diverse stakeholders. Consequently, 3 main concepts, complemented by 72 sub-concepts, were delineated, all fostering positive contributions to climate protection and providing heat supply in the rural study area. The outcomes' replicability is underscored by the study area's generic structure and the employed methodology. Through these inquiries, a framework for the requisite energy transition, with a pronounced emphasis on the coupling of waste, wastewater, and agriculture sectors in rural environments, is robustly analyzed.}, subject = {Energiewende}, language = {en} } @phdthesis{Pastohr2004, author = {Pastohr, Henry}, title = {Thermodynamische Modellierung eines Aufwindkraftwerkes}, doi = {10.25643/bauhaus-universitaet.81}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20040803-867}, school = {Bauhaus-Universit{\"a}t Weimar}, year = {2004}, abstract = {Die Energieversorgung auf der Erde wird zuk{\"u}nftig zu einem Problem. Bedingt ist dies durch eine fortschreitende Verknappung der nat{\"u}rlichen Ressourcen, wie Kohle, Gas und {\"O}l sowie einer Zunahme der CO2-Konzentration und anderer Schadstoffe in der Atmosph{\"a}re. Regenerative Energiequellen m{\"u}ssen genutzt werden, um den steigenden Energiebedarf zu sichern. Eine interessante M{\"o}glichkeit zur Nutzung der Solarenergie stellt das Aufwindkraftwerk dar. Das Aufwindkraftwerk besteht aus einem Kamin, um den ein Glasdachkollektor auf dem Erdboden angeordnet ist. Am Fuße des Kamins befinden sich Turbinen und Generatoren. Die einfallende Solarenergie wird haupts{\"a}chlich {\"u}ber die Wechselwirkung mit dem Erdreich in thermische Energie, in kinetische Energie, in Rotationsenergie und in elektrische Energie umgewandelt. Das Ziel der Arbeit bestand in der physikalisch-mathematischen Modellierung, der genaueren Erkennung des Wirkprinzips und der Diskussion der Anlagenparameter Leistung und Wirkungsgrad. Im Rahmen dieser Aufgabe wurden dazu station{\"a}re und instation{\"a}re Computational Fluid Dynamic (CFD) Modelle und station{\"a}re und instation{\"a}re vereinfachte Modelle entwickelt, diskutiert und miteinander verglichen. Grundlegend neue Erkenntnisse wurden bei den Verl{\"a}ufen der Temperaturen im Kollektor, insbesondere der Erdoberfl{\"a}chentemperatur erreicht. Parameteranpassungen im W{\"a}rme{\"u}bergangsmodell und Widerstandsmodell f{\"u}hrten f{\"u}r vier ausgew{\"a}hlte, station{\"a}re Sonnenenergien auf eine gute {\"U}bereinstimmung zwischen den Ergebnissen (Temperaturhub, Druckentnahme, Leistung und Wirkungsgrad) des station{\"a}ren, hybriden Modells und des station{\"a}ren CFD-Modells. Weiterhin stimmen die lokalen Gr{\"o}ßen W{\"a}rme{\"u}bergangskoeffizient, Erdoberfl{\"a}chentemperatur, Lufttemperatur und Glasdachtemperatur gut zwischen den Modellen {\"u}berein. Mit dem CFD Modell wurden der Prototyp und 3 Großkraftwerke berechnet. Mit dem entwickelten instation{\"a}ren FDM-Modell wurden erstmalig numerische Langzeitsimulationen (1 Jahr) durchgef{\"u}hrt. Zur {\"U}berpr{\"u}fung des Modells wurden die Ergebnisse mit Messwerten aus Manzanares verglichen, wobei eine gute {\"U}bereinstimmung erreicht werden konnte. Das Verst{\"a}ndnis f{\"u}r die stattfindenden thermodynamischen und str{\"o}mungsmechanischen Prozesse in einem Aufwindkraftwerk konnte durch die Arbeit maßgeblich verbessert werden.}, subject = {Aufwindkraftwerk}, language = {de} } @misc{MuellerHennigAubeletal., author = {M{\"u}ller, Naira and Hennig, Christoph and Aubel, Mario and Hesse, Tobias and Schneider, Sascha}, title = {FlipLife als Mitarbeiterrekrutierungsquelle}, doi = {10.25643/bauhaus-universitaet.1572}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20120229-15727}, pages = {101}, abstract = {Ausgehend von der Aufgabenstellung umreißt diese Arbeit die Besonderheiten der Mitarbeiterrekrutierung und deren Anwendung im Internet, im speziellen bei Social-Games, gemessen an dem Spiel FlipLife.}, subject = {Fliplife Mitarbeiterrekrutierung}, language = {de} } @masterthesis{Mueller, type = {Bachelor Thesis}, author = {M{\"u}ller, Naira}, title = {Erweiterung von Fliplife mit bauphysikalischen Inhalten}, doi = {10.25643/bauhaus-universitaet.1676}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20120704-16763}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {105}, abstract = {In dieser Arbeit wurde ein Konzept erstellt, das Fliplife um einen bauphysikalischen Karriereweg erweitert. In das Spiel wurden beispielhaft bauphysikalische Inhalte sowie spielkonzept-kompatible und wissensvermittelnde Spielmechaniken implementiert.}, subject = {Social Game}, language = {de} } @masterthesis{Linda, type = {Bachelor Thesis}, author = {Linda, Luthardt}, title = {Systematik von Interaktionen zwischen mehreren Spielern in Social Network Spielen}, doi = {10.25643/bauhaus-universitaet.1661}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20120530-16610}, school = {Bauhaus-Universit{\"a}t Weimar}, pages = {92}, abstract = {Herausarbeitung sozialer Interaktionen in Social Games und deren m{\"o}gliche Anwendung um fachspezifische Lehrinhalte,z.B. aus dem Bereich der Bauphysik zu vermitteln.}, subject = {Gesellschaftsspiel}, language = {de} } @masterthesis{Kuehnert2011, type = {Bachelor Thesis}, author = {K{\"u}hnert, Christin}, title = {Entwicklung von Spielmechaniken f{\"u}r ein bauphysikalisches Social Game}, doi = {10.25643/bauhaus-universitaet.1522}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20120117-15227}, school = {Bauhaus-Universit{\"a}t Weimar}, year = {2011}, abstract = {Eine der j{\"u}ngsten Entwicklungen in der Games Branche sind sogenannte Social Games. Hierbei handelt es sich um digitale Spiele, die innerhalb von sozialen Netzwerken, wie z.B. Facebook und Myspace, gespielt werden. Studien zeigen, dass kommerzielle digitale Spiele mehr als nur ein Zeitvertreib sind. Sie f{\"o}rdern sowohl kognitive, als auch affektive und psychomotorische Kompetenzen. Aus diesem Grund werden seit Jahrzehnten digitale Spiele in der P{\"a}dagogik eingesetzt, um ihre Motivationskraft zu nutzen, um Lerneffekte zu erzielen. Ziel dieser Arbeit ist es Spielmechaniken f{\"u}r ein bauphysikalisches Social Game zu entwickeln. Ausgehend von der Identifikation von Spielmechaniken, basierend auf einer Analyse der Funktionsweisen existierender popul{\"a}rer Social Games, und einem grundlegenden p{\"a}dagogischen Verst{\"a}ndnis bez{\"u}glich Digital Game Based Learning (DGBL), werden Spielmechaniken entwickelt, mit deren Hilfe bauphysikalische Fachkompetenzen vermittelt werden k{\"o}nnen.}, subject = {Computerunterst{\"u}tztes Lernen}, language = {de} }