@article{AlsaadVoelker, author = {Alsaad, Hayder and V{\"o}lker, Conrad}, title = {Der K{\"u}hlungseffekt der personalisierten L{\"u}ftung}, series = {Bauphysik}, volume = {2020}, journal = {Bauphysik}, number = {volume 42, issue 5}, publisher = {Ernst \& Sohn bei John Wiley \& Sons}, address = {Hoboken}, doi = {10.25643/bauhaus-universitaet.4272}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20201020-42723}, pages = {218 -- 225}, abstract = {Personalisierte L{\"u}ftung (PL) kann die thermische Behaglichkeit sowie die Qualit{\"a}t der eingeatmeten Atemluft verbessern, in dem jedem Arbeitsplatz Frischluft separat zugef{\"u}hrt wird. In diesem Beitrag wird die Wirkung der PL auf die thermische Behaglichkeit der Nutzer unter sommerlichen Randbedingungen untersucht. Hierf{\"u}r wurden zwei Ans{\"a}tze zur Bewertung des K{\"u}hlungseffekts der PL untersucht: basierend auf (1) der {\"a}quivalenten Temperatur und (2) dem thermischen Empfinden. Grundlage der Auswertung sind in einer Klimakammer gemessene sowie numerisch simulierte Daten. Vor der Durchf{\"u}hrung der Simulationen wurde das numerische Modell zun{\"a}chst anhand der gemessenen Daten validiert. Die Ergebnisse zeigen, dass der Ansatz basierend auf dem thermischen Empfinden zur Evaluierung des K{\"u}hlungseffekts der PL sinnvoller sein kann, da bei diesem die komplexen physiologischen Faktoren besser ber{\"u}cksichtigt werden.}, subject = {L{\"u}ftung}, language = {de} } @article{AlsaadVoelker, author = {Alsaad, Hayder and V{\"o}lker, Conrad}, title = {Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations}, series = {Indoor Air}, volume = {2020}, journal = {Indoor Air}, publisher = {John Wiley \& Sons Ltd}, doi = {10.1111/ina.12672}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20200422-41407}, pages = {14}, abstract = {The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant.}, subject = {Behaglichkeit}, language = {en} } @article{AlsaadVoelker, author = {Alsaad, Hayder and V{\"o}lker, Conrad}, title = {Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation?}, series = {Indoor Air}, volume = {2020}, journal = {Indoor Air}, publisher = {John Wiley \& Sons Ltd}, doi = {10.1111/ina.12720}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20200805-42072}, pages = {13}, abstract = {This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off.}, subject = {Str{\"o}mungsmechanik}, language = {en} } @article{AlsaadVoelker, author = {Alsaad, Hayder and V{\"o}lker, Conrad}, title = {Performance assessment of a ductless personalized ventilation system using a validated CFD model}, series = {Journal of Building Performance Simulation}, volume = {2018}, journal = {Journal of Building Performance Simulation}, number = {11, Heft 6}, doi = {10.25643/bauhaus-universitaet.3850}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20190218-38500}, pages = {689 -- 704}, abstract = {The aim of this study is twofold: to validate a computational fluid dynamics (CFD) model, and then to use the validated model to evaluate the performance of a ductless personalized ventilation (DPV) system. To validate the numerical model, a series of measurements was conducted in a climate chamber equipped with a thermal manikin. Various turbulence models, settings, and options were tested; simulation results were compared to the measured data to determine the turbulence model and solver settings that achieve the best agreement between the measured and simulated values. Subsequently, the validated CFD model was then used to evaluate the thermal environment and indoor air quality in a room equipped with a DPV system combined with displacement ventilation. Results from the numerical model were then used to quantify thermal sensation and comfort using the UC Berkeley thermal comfort model.}, subject = {Ventilation}, language = {en} } @article{VoelkerAlsaad, author = {V{\"o}lker, Conrad and Alsaad, Hayder}, title = {Simulating the human body's microclimate using automatic coupling of CFD and an advanced thermoregulation model}, series = {Indoor Air}, volume = {2018}, journal = {Indoor Air}, number = {28, Heft 3}, doi = {10.25643/bauhaus-universitaet.3851}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20190218-38517}, pages = {415 -- 425}, abstract = {This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of the human body back and forth between the CFD solver and the UCB model until reaching convergence defined by a stopping criterion. The location from which data are transferred to the UCB model was determined using a new approach based on the temperature difference between subsequent points on the temperature profile curve in the vicinity of the body surface. This approach was used because the microclimate surrounding the human body differs in thickness depending on the body segment and the surrounding environment. To accurately simulate the thermal environment, the numerical model was validated beforehand using experimental data collected in a climate chamber equipped with a thermal manikin. Furthermore, an example of the practical implementations of this coupling is reported in this paper through radiant floor cooling simulation cases, in which overall and local thermal sensation and comfort were investigated using the coupled UCB model.}, subject = {Numerische Str{\"o}mungssimulation}, language = {en} }