@techreport{MuellerSeidelLudwigetal., author = {M{\"u}ller, Christoph and Seidel, Maik and Ludwig, Horst-Michael and M{\"u}ller, Matthias}, title = {Pr{\"u}fung des Frost-Tausalz-Widerstandes von Beton f{\"u}r die Expositionsklasse XF2}, doi = {10.25643/bauhaus-universitaet.4887}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20240226-48877}, pages = {34}, abstract = {In cold and moderate climates concrete can be subjected to a combined salt frost attack, which can cause scaling damage. Consequently, numerous test procedures were developed to determine the resistance of concrete compositions against this kind of attack. These tests typically mimic a severe attack with high levels of saturation, e.g. as for concrete pavements. Very few approaches exist for testing the salt frost scaling resistance of concretes, which are subjected only to medium levels of saturation, as such concrete elements typically don't show notable scaling damage. However, the increasing use of low carbon cements with high clinker substitution rates might affect the salt frost scaling resistance of such concrete elements to some extent. To ensure adequate durability of such concretes it is thus desirable to determine their performance in an actual test procedure instead of relying on past experience. Thus, less severe test methods was developed, which are based on the Slab test and the CDF test, repectively.}, subject = {Beton}, language = {de} } @inproceedings{MuellerEhrhardtLudwig, author = {M{\"u}ller, Matthias and Ehrhardt, Dirk and Ludwig, Horst-Michael}, title = {Optimierung der Nachbehandlung von Waschbetonoberfl{\"a}chen}, series = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, booktitle = {Tagungsband 18. Ibausil - 18. Internationale Baustofftagung : 12.-15. September 2012, Weimar}, editor = {Ludwig, Horst-Michael}, organization = {F.A.Finger-Institut f{\"u}r Baustoffkunde, Bauhaus-Universit{\"a}t Weimar}, isbn = {978-3-00-034075-8}, doi = {10.25643/bauhaus-universitaet.4872}, url = {http://nbn-resolving.de/urn:nbn:de:gbv:wim2-20240226-48722}, pages = {794-781}, abstract = {Der Nachbehandlung eines Fahrbahndeckenbetons kommt zum Erzielen eines hohen Frost-Tausalz-Widerstandes der fertigen Betondecke eine besondere Bedeutung zu. Bei der Waschbetonbauweise erfolgt die Nachbehandlung in mehreren Schritten. Eine erste Nachbehandlung gew{\"a}hrleistet den Verdunstungsschutz des Betons bis zum Zeitpunkt des Ausb{\"u}rstens des verz{\"o}gerten Oberfl{\"a}chenm{\"o}rtels. Daran schließt sich die zweite Nachbehandlung an, in der Regel durch Aufspr{\"u}hen eines fl{\"u}ssigen Nachbehandlungsmittels. Der zweite Nachbehandlungsschritt ist entscheidend f{\"u}r den Frost-Tausalz-Widerstand der Betondecke. Im Rahmen eines Forschungsprojektes wurde daher untersucht, inwiefern durch eine Optimierung der zweiten Nachbehandlung der Frost-Tausalz-Widerstand von Waschbetonoberfl{\"a}chen erh{\"o}ht werden kann, insbesondere bei Verwendung h{\"u}ttensandhaltiger Zemente. Schon durch eine einmalige Nassnachbehandlung wurde eine deutlich h{\"o}herer Widerstand der Waschbetons gegen Frost-Tausalz-Angriff erzielt.}, subject = {Beton}, language = {de} }